/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.6.2-desktop-1omv2390] (OpenMandriva Lx 7.4-1)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: WDC PC SN720 SDAPNTW-256G-1006
Serial Number: --
Firmware Version: 10112006
PCI Vendor/Subsystem ID: 0x15b7
IEEE OUI Identifier: 0x001b44
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 8215
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 001b44 ...
Local Time is: Fri Jan 17 11:50:58 2025 EST
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x02): Cmd_Eff_Lg
Maximum Data Transfer Size: 128 Pages
Warning Comp. Temp. Threshold: 80 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Namespace 1 Features (0x02): NA_Fields
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W - - 0 0 0 0 0 0
1 + 3.50W - - 1 1 1 1 0 0
2 + 3.00W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 4000 10000
4 - 0.0025W - - 4 4 4 4 4000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 35 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 1,833,257 [938 GB]
Data Units Written: 2,765,526 [1.41 TB]
Host Read Commands: 6,542,928
Host Write Commands: 7,891,401
Controller Busy Time: 29
Power Cycles: 56
Power On Hours: 41
Unsafe Shutdowns: 31
Media and Data Integrity Errors: 0
Error Information Log Entries: 6
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged
Read Self-test Log failed: Invalid Field in Command (0x4002)
/dev/nvme1n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.6.2-desktop-1omv2390] (OpenMandriva Lx 7.4-1)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PC711 NVMe SK hynix 256GB
Serial Number: --
Firmware Version: 41001131
PCI Vendor/Subsystem ID: 0x1c5c
IEEE OUI Identifier: 0xace42e
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: ace42e ...
Local Time is: Fri Jan 17 11:50:58 2025 EST
Firmware Updates (0x16): 3 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 6.3000W - - 0 0 0 0 5 5
1 + 2.4000W - - 1 1 1 1 30 30
2 + 1.9000W - - 2 2 2 2 100 100
3 - 0.0500W - - 3 3 3 3 1000 1000
4 - 0.0040W - - 3 3 3 3 1000 9000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 41 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 1%
Data Units Read: 28,607,501 [14.6 TB]
Data Units Written: 55,570,667 [28.4 TB]
Host Read Commands: 481,952,424
Host Write Commands: 1,665,850,803
Controller Busy Time: 3,081
Power Cycles: 149
Power On Hours: 20,675
Unsafe Shutdowns: 116
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 34 Celsius
Temperature Sensor 2: 35 Celsius
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged
Read Self-test Log failed: Invalid Field in Command (0x002)