/dev/nvme0n1
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-6.2.6-76060206-generic] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: SAMSUNG MZVLB1T0HALR-000H1
Serial Number: --
Firmware Version: EXA73H1Q
PCI Vendor/Subsystem ID: 0x144d
IEEE OUI Identifier: 0x002538
Total NVM Capacity: 1,024,209,543,168 [1.02 TB]
Unallocated NVM Capacity: 0
Controller ID: 4
NVMe Version: 1.2
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,024,209,543,168 [1.02 TB]
Namespace 1 Utilization: 222,478,520,320 [222 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 002538 ...
Local Time is: Wed Mar 29 15:20:56 2023 CEST
Firmware Updates (0x16): 3 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 81 Celsius
Critical Comp. Temp. Threshold: 82 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.02W - - 0 0 0 0 0 0
1 + 6.30W - - 1 1 1 1 0 0
2 + 3.50W - - 2 2 2 2 0 0
3 - 0.0760W - - 3 3 3 3 210 1200
4 - 0.0050W - - 4 4 4 4 2000 8000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 72 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 1%
Data Units Read: 27,076,100 [13.8 TB]
Data Units Written: 23,083,114 [11.8 TB]
Host Read Commands: 144,073,420
Host Write Commands: 70,517,238
Controller Busy Time: 383
Power Cycles: 2,763
Power On Hours: 620
Unsafe Shutdowns: 164
Media and Data Integrity Errors: 0
Error Information Log Entries: 6,387
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 72 Celsius
Temperature Sensor 2: 103 Celsius
Error Information (NVMe Log 0x01, 16 of 256 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 6387 0 0x0000 0x4004 - 0 0 -
/dev/nvme1n1
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-6.2.6-76060206-generic] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: SAMSUNG MZVLB512HAJQ-000H7
Serial Number: --
Firmware Version: EXA73H2Q
PCI Vendor/Subsystem ID: 0x144d
IEEE OUI Identifier: 0x002538
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 4
NVMe Version: 1.2
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Utilization: 44,603,457,536 [44.6 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 002538 ...
Local Time is: Wed Mar 29 15:20:56 2023 CEST
Firmware Updates (0x16): 3 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 81 Celsius
Critical Comp. Temp. Threshold: 82 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.02W - - 0 0 0 0 0 0
1 + 6.30W - - 1 1 1 1 0 0
2 + 3.50W - - 2 2 2 2 0 0
3 - 0.0760W - - 3 3 3 3 210 1200
4 - 0.0050W - - 4 4 4 4 2000 8000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 47 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 3%
Data Units Read: 34,834,148 [17.8 TB]
Data Units Written: 38,356,988 [19.6 TB]
Host Read Commands: 452,058,312
Host Write Commands: 382,948,067
Controller Busy Time: 1,482
Power Cycles: 2,765
Power On Hours: 1,762
Unsafe Shutdowns: 163
Media and Data Integrity Errors: 0
Error Information Log Entries: 8,449
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 47 Celsius
Temperature Sensor 2: 56 Celsius
Error Information (NVMe Log 0x01, 16 of 256 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 8449 0 0x0008 0x4004 - 0 0 -