Probe #3355032413 of Dell Inspiron 5748

Log: smartctl

/dev/sda smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.9-desktop-1omv2490] (OpenMandriva Lx 7.4-1) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Momentus 7200.2 Device Model: ST980813AS Serial Number: -- Firmware Version: 3.ADB User Capacity: 80,026,361,856 bytes [80.0 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database ATA Version is: ATA/ATAPI-7 (minor revision not indicated) Local Time is: Tue Feb 18 21:08:16 2025 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Unexpected SCT status 0xffff (action_code=4, function_code=2) Wt Cache Reorder: Unknown (SCT Feature Control command failed) === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 25) The self-test routine was aborted by the host. Total time to complete Offline data collection: ( 426) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 84) minutes. SCT capabilities: (0x0035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 100 253 006 - 0 3 Spin_Up_Time PO---- 099 099 085 - 0 4 Start_Stop_Count -O--CK 100 100 020 - 790 5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0 7 Seek_Error_Rate POSR-- 084 060 030 - 327130638 9 Power_On_Hours -O--CK 087 087 000 - 12013 10 Spin_Retry_Count PO--C- 100 100 034 - 0 12 Power_Cycle_Count -O--CK 100 100 020 - 835 187 Reported_Uncorrect -O--CK 100 100 000 - 0 189 High_Fly_Writes -O-RCK 100 100 000 - 0 190 Airflow_Temperature_Cel -O---K 071 041 045 Past 29 (0 212 29 24 0) 191 G-Sense_Error_Rate -O--CK 100 100 000 - 0 192 Power-Off_Retract_Count -O--CK 100 100 000 - 633 193 Load_Cycle_Count -O---K 001 001 000 - 401890 194 Temperature_Celsius -O-RC- 029 059 000 - 29 (0 14 0 0 0) 195 Hardware_ECC_Recovered -O--C- 080 060 000 - 103459306 197 Current_Pending_Sector ----C- 100 100 000 - 0 198 Offline_Uncorrectable -OSRCK 100 100 000 - 0 199 UDMA_CRC_Error_Count ------ 200 200 000 - 0 200 Multi_Zone_Error_Rate -O--CK 100 253 000 - 0 202 Data_Address_Mark_Errs ------ 100 253 000 - 0 254 Free_Fall_Sensor ------ 100 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory not supported SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 SL R/O 5 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 SL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 SL R/O 1 NCQ Command Error log 0x11 SL R/O 1 SATA Phy Event Counters log 0x20 SL R/O 1 Streaming performance log 0x21 SL R/O 1 Write stream error log 0x22 SL R/O 1 Read stream error log 0x23 SL R/O 1 Delayed sector log 0x80-0x9f SL R/W 16 Host vendor specific log 0xa0 SL VS 1 Device vendor specific log 0xa1 SL VS 20 Device vendor specific log 0xa2 SL VS 101 Device vendor specific log 0xa8 SL VS 20 Device vendor specific log 0xa9 SL VS 1 Device vendor specific log 0xe0 SL R/W 1 SCT Command/Status 0xe1 SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log Version: 1 No Errors Logged SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Aborted by host 90% 11965 - # 2 Short offline Completed without error 00% 11912 - # 3 Short offline Completed without error 00% 11912 - # 4 Short offline Completed without error 00% 2 - # 5 Extended offline Completed without error 00% 0 - # 6 Short offline Completed without error 00% 0 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 521 (0x0209) Device State: Active (0) Current Temperature: 29 Celsius Power Cycle Min/Max Temperature: 27/29 Celsius Lifetime Min/Max Temperature: 15/59 Celsius Specified Max Operating Temperature: 38 Celsius Under/Over Temperature Limit Count: 0/0 Another SCT command is executing, abort Read Data Table (SCT ext_status_code 0xffff, action_code=4, function_code=2) Read SCT Temperature History failed SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x000a 2 3 Device-to-host register FISes sent due to a COMRESET 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy 0x8002 2 0 Vendor specific 0x8003 2 3 Vendor specific 0x8004 2 0 Vendor specific


Hardware for Linux and BSD

GitHub