/dev/sda
smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-40-generic] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Samsung SpinPoint M8 (AF)
Device Model: ST1000LM024 HN-M101MBB
Serial Number: --
LU WWN Device Id: 5 0004cf ...
Firmware Version: 2BA30003
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Jul 19 19:22:58 2020 -03
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (13680) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 228) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 11
2 Throughput_Performance -OS--K 252 252 000 - 0
3 Spin_Up_Time PO---K 092 091 025 - 2658
4 Start_Stop_Count -O--CK 090 090 000 - 10991
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
8 Seek_Time_Performance --S--K 252 252 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 19222
10 Spin_Retry_Count -O--CK 252 252 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 1
12 Power_Cycle_Count -O--CK 095 095 000 - 5104
13 Read_Soft_Error_Rate -O-RCK 100 100 000 - 0
181 Program_Fail_Cnt_Total -O---K 098 098 000 - 56520048
191 G-Sense_Error_Rate -O---K 100 100 000 - 13
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
193 Load_Cycle_Count -O--CK 085 085 000 - 153055
194 Temperature_Celsius -O---- 054 030 000 - 46 (Min/Max 16/70)
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
197 Current_Pending_Sector -O--CK 252 100 000 - 0
198 Offline_Uncorrectable ----CK 252 252 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 278
240 Head_Flying_Hours -O--CK 100 100 000 - 15095
241 Total_LBAs_Written -O--CK 092 088 000 - 11637779
242 Total_LBAs_Read -O--CK 097 088 000 - 5098069
254 Free_Fall_Sensor -O--CK 252 252 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 2 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xc0-0xdf GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Device Error Count: 32 (device log contains only the most recent 8 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 32 [7] occurred at disk power-on lifetime: 2901 hours (120 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 02 00 00 00 00 27 c6 17 e0 00
Error: UNC at LBA = 0x0027c617 = 2606615
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 da 82 02 00 00 00 00 27 c6 17 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 17 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 17 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 17 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
42 da 82 00 01 00 00 00 27 c6 16 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
Error 31 [6] occurred at disk power-on lifetime: 2901 hours (120 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 02 00 00 00 00 27 c6 17 e0 00
Error: UNC at LBA = 0x0027c617 = 2606615
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 da 82 02 00 00 00 00 27 c6 17 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 17 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 17 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
42 da 82 00 01 00 00 00 27 c6 16 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
35 da 82 00 01 00 00 00 27 c6 16 e0 00 00:00:00.033 WRITE DMA EXT
Error 30 [5] occurred at disk power-on lifetime: 2901 hours (120 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 02 00 00 00 00 27 c6 17 e0 00
Error: UNC at LBA = 0x0027c617 = 2606615
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 da 82 02 00 00 00 00 27 c6 17 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 17 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
42 da 82 00 01 00 00 00 27 c6 16 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
35 da 82 00 01 00 00 00 27 c6 16 e0 00 00:00:00.033 WRITE DMA EXT
42 da 82 02 00 00 00 00 27 c6 16 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
Error 29 [4] occurred at disk power-on lifetime: 2901 hours (120 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 02 00 00 00 00 27 c6 17 e0 00
Error: UNC at LBA = 0x0027c617 = 2606615
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 da 82 02 00 00 00 00 27 c6 17 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
42 da 82 00 01 00 00 00 27 c6 16 e0 00 00:00:00.033 READ VERIFY SECTOR(S) EXT
35 da 82 00 01 00 00 00 27 c6 16 e0 00 00:00:00.033 WRITE DMA EXT
42 da 82 02 00 00 00 00 27 c6 16 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 16 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
Error 28 [3] occurred at disk power-on lifetime: 2901 hours (120 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 02 00 00 00 00 27 c6 16 e0 00
Error: UNC at LBA = 0x0027c616 = 2606614
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 da 82 02 00 00 00 00 27 c6 16 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 16 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 16 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 16 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
42 da 82 00 01 00 00 00 27 c6 15 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
Error 27 [2] occurred at disk power-on lifetime: 2901 hours (120 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 02 00 00 00 00 27 c6 16 e0 00
Error: UNC at LBA = 0x0027c616 = 2606614
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 da 82 02 00 00 00 00 27 c6 16 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 16 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 16 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
42 da 82 00 01 00 00 00 27 c6 15 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
35 da 82 00 01 00 00 00 27 c6 15 e0 00 00:00:00.032 WRITE DMA EXT
Error 26 [1] occurred at disk power-on lifetime: 2901 hours (120 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 02 00 00 00 00 27 c6 16 e0 00
Error: UNC at LBA = 0x0027c616 = 2606614
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 da 82 02 00 00 00 00 27 c6 16 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 16 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
42 da 82 00 01 00 00 00 27 c6 15 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
35 da 82 00 01 00 00 00 27 c6 15 e0 00 00:00:00.032 WRITE DMA EXT
42 da 82 02 00 00 00 00 27 c6 15 e0 00 00:00:00.031 READ VERIFY SECTOR(S) EXT
Error 25 [0] occurred at disk power-on lifetime: 2901 hours (120 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 02 00 00 00 00 27 c6 16 e0 00
Error: UNC at LBA = 0x0027c616 = 2606614
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 da 82 02 00 00 00 00 27 c6 16 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
42 da 82 00 01 00 00 00 27 c6 15 e0 00 00:00:00.032 READ VERIFY SECTOR(S) EXT
35 da 82 00 01 00 00 00 27 c6 15 e0 00 00:00:00.032 WRITE DMA EXT
42 da 82 02 00 00 00 00 27 c6 15 e0 00 00:00:00.031 READ VERIFY SECTOR(S) EXT
42 da 82 02 00 00 00 00 27 c6 15 e0 00 00:00:00.031 READ VERIFY SECTOR(S) EXT
SMART Extended Self-test Log Version: 1 (2 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 14946 -
# 2 Short offline Completed without error 00% 13746 -
# 3 Short offline Completed without error 00% 2905 -
# 4 Short offline Completed without error 00% 2905 -
# 5 Short offline Completed without error 00% 2905 -
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed [00% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 46 Celsius
Power Cycle Min/Max Temperature: 44/54 Celsius
Lifetime Min/Max Temperature: 16/70 Celsius
Specified Max Operating Temperature: 80 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 5 minutes
Temperature Logging Interval: 5 minutes
Min/Max recommended Temperature: -5/80 Celsius
Min/Max Temperature Limit: -10/85 Celsius
Temperature History Size (Index): 128 (46)
Index Estimated Time Temperature Celsius
47 2020-07-19 08:45 46 ***************************
48 2020-07-19 08:50 45 **************************
49 2020-07-19 08:55 48 *****************************
50 2020-07-19 09:00 50 *******************************
51 2020-07-19 09:05 50 *******************************
52 2020-07-19 09:10 51 ********************************
... ..( 14 skipped). .. ********************************
67 2020-07-19 10:25 51 ********************************
68 2020-07-19 10:30 52 *********************************
69 2020-07-19 10:35 52 *********************************
70 2020-07-19 10:40 52 *********************************
71 2020-07-19 10:45 51 ********************************
72 2020-07-19 10:50 51 ********************************
73 2020-07-19 10:55 50 *******************************
74 2020-07-19 11:00 50 *******************************
75 2020-07-19 11:05 50 *******************************
76 2020-07-19 11:10 49 ******************************
77 2020-07-19 11:15 49 ******************************
78 2020-07-19 11:20 45 **************************
79 2020-07-19 11:25 46 ***************************
80 2020-07-19 11:30 47 ****************************
81 2020-07-19 11:35 48 *****************************
82 2020-07-19 11:40 50 *******************************
83 2020-07-19 11:45 51 ********************************
84 2020-07-19 11:50 52 *********************************
85 2020-07-19 11:55 53 **********************************
86 2020-07-19 12:00 54 ***********************************
... ..( 3 skipped). .. ***********************************
90 2020-07-19 12:20 54 ***********************************
91 2020-07-19 12:25 55 ************************************
... ..( 3 skipped). .. ************************************
95 2020-07-19 12:45 55 ************************************
96 2020-07-19 12:50 56 *************************************
97 2020-07-19 12:55 55 ************************************
... ..( 3 skipped). .. ************************************
101 2020-07-19 13:15 55 ************************************
102 2020-07-19 13:20 54 ***********************************
103 2020-07-19 13:25 53 **********************************
104 2020-07-19 13:30 53 **********************************
105 2020-07-19 13:35 54 ***********************************
106 2020-07-19 13:40 54 ***********************************
107 2020-07-19 13:45 55 ************************************
108 2020-07-19 13:50 56 *************************************
109 2020-07-19 13:55 57 **************************************
110 2020-07-19 14:00 58 ***************************************
111 2020-07-19 14:05 58 ***************************************
112 2020-07-19 14:10 57 **************************************
113 2020-07-19 14:15 59 ****************************************
114 2020-07-19 14:20 60 ***************************************+
115 2020-07-19 14:25 37 ******************
116 2020-07-19 14:30 43 ************************
117 2020-07-19 14:35 48 *****************************
118 2020-07-19 14:40 52 *********************************
119 2020-07-19 14:45 54 ***********************************
120 2020-07-19 14:50 56 *************************************
121 2020-07-19 14:55 56 *************************************
122 2020-07-19 15:00 56 *************************************
123 2020-07-19 15:05 55 ************************************
124 2020-07-19 15:10 55 ************************************
125 2020-07-19 15:15 54 ***********************************
126 2020-07-19 15:20 53 **********************************
127 2020-07-19 15:25 52 *********************************
0 2020-07-19 15:30 51 ********************************
1 2020-07-19 15:35 51 ********************************
2 2020-07-19 15:40 51 ********************************
3 2020-07-19 15:45 50 *******************************
4 2020-07-19 15:50 50 *******************************
5 2020-07-19 15:55 49 ******************************
6 2020-07-19 16:00 49 ******************************
7 2020-07-19 16:05 48 *****************************
8 2020-07-19 16:10 49 ******************************
... ..( 2 skipped). .. ******************************
11 2020-07-19 16:25 49 ******************************
12 2020-07-19 16:30 48 *****************************
13 2020-07-19 16:35 48 *****************************
14 2020-07-19 16:40 48 *****************************
15 2020-07-19 16:45 29 **********
16 2020-07-19 16:50 37 ******************
17 2020-07-19 16:55 42 ***********************
18 2020-07-19 17:00 44 *************************
19 2020-07-19 17:05 44 *************************
20 2020-07-19 17:10 47 ****************************
21 2020-07-19 17:15 48 *****************************
22 2020-07-19 17:20 48 *****************************
23 2020-07-19 17:25 51 ********************************
24 2020-07-19 17:30 52 *********************************
25 2020-07-19 17:35 52 *********************************
26 2020-07-19 17:40 53 **********************************
27 2020-07-19 17:45 53 **********************************
28 2020-07-19 17:50 55 ************************************
29 2020-07-19 17:55 56 *************************************
30 2020-07-19 18:00 56 *************************************
31 2020-07-19 18:05 55 ************************************
... ..( 5 skipped). .. ************************************
37 2020-07-19 18:35 55 ************************************
38 2020-07-19 18:40 59 ****************************************
39 2020-07-19 18:45 61 ***************************************+
40 2020-07-19 18:50 61 ***************************************+
41 2020-07-19 18:55 60 ***************************************+
42 2020-07-19 19:00 58 ***************************************
43 2020-07-19 19:05 57 **************************************
44 2020-07-19 19:10 44 *************************
45 2020-07-19 19:15 45 **************************
46 2020-07-19 19:20 46 ***************************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 0 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8e00 4 0 Vendor specific
0x8e01 4 0 Vendor specific
0x8e02 4 0 Vendor specific
0x8e03 4 0 Vendor specific
0x8e04 4 0 Vendor specific
0x8e05 4 0 Vendor specific
0x8e06 4 0 Vendor specific
0x8e07 4 0 Vendor specific
0x8e08 4 0 Vendor specific
0x8e09 4 0 Vendor specific
0x8e0a 4 0 Vendor specific
0x8e0b 4 0 Vendor specific
0x8e0c 4 0 Vendor specific
0x8e0d 4 0 Vendor specific
0x8e0e 4 0 Vendor specific
0x8e0f 4 0 Vendor specific
0x8e10 4 0 Vendor specific
0x8e11 4 0 Vendor specific
/dev/sdb
smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-40-generic] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: Samsung SSD 850 EVO mSATA 250GB
Serial Number: --
LU WWN Device Id: 5 002538 ...
Firmware Version: EMT41B6Q
User Capacity: 250,059,350,016 bytes [250 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: mSATA
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Jul 19 19:22:59 2020 -03
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Read SCT Status failed: scsi error badly formed scsi parameters
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 133) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 096 096 000 - 15366
12 Power_Cycle_Count -O--CK 097 097 000 - 3027
177 Wear_Leveling_Count PO--C- 094 094 000 - 123
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 061 036 000 - 39
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 100 100 000 - 0
235 POR_Recovery_Count -O--C- 099 099 000 - 117
241 Total_LBAs_Written -O--CK 099 099 000 - 46253437546
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 SL VS 16 Device vendor specific log
0xa5 SL VS 16 Device vendor specific log
0xce SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 13019 -
# 2 Short offline Completed without error 00% 11019 -
# 3 Short offline Completed without error 00% 9761 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
255 0 65535 Read_scanning was never started
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Read SCT Status failed: scsi error badly formed scsi parameters
Read SCT Status failed: scsi error badly formed scsi parameters
SCT (Get) Error Recovery Control command failed
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC