/dev/nvme0n1
smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.12.34-generic-1rosa13-x86_64] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: WDS500G1X0E-00AFY0
Serial Number: --
Firmware Version: 613200WD
PCI Vendor/Subsystem ID: 0x15b7
IEEE OUI Identifier: 0x001b44
Total NVM Capacity: 500,107,862,016 [500 GB]
Unallocated NVM Capacity: 0
Controller ID: 8224
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 500,107,862,016 [500 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 001b44 ...
Local Time is: Sun Aug 10 16:11:28 2025 MSK
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 128 Pages
Warning Comp. Temp. Threshold: 84 Celsius
Critical Comp. Temp. Threshold: 88 Celsius
Namespace 1 Features (0x02): NA_Fields
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 9.00W 9.00W - 0 0 0 0 0 0
1 + 4.10W 4.10W - 0 0 0 0 0 0
2 + 3.50W 3.50W - 0 0 0 0 0 0
3 - 0.0250W - - 3 3 3 3 5000 10000
4 - 0.0050W - - 4 4 4 4 5000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02, NSID 0xffffffff)
Critical Warning: 0x00
Temperature: 47 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 2%
Data Units Read: 20,730,464 [10.6 TB]
Data Units Written: 33,821,677 [17.3 TB]
Host Read Commands: 198,448,485
Host Write Commands: 308,793,889
Controller Busy Time: 508
Power Cycles: 934
Power On Hours: 136
Unsafe Shutdowns: 397
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 26
Critical Comp. Temperature Time: 11
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06, NSID 0xffffffff)
Self-test status: No self-test in progress
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
0 Short Completed without error 135 - - - - -
1 Short Completed without error 108 - - - - -
2 Short Completed without error 5 - - - - -
/dev/sda
smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.12.34-generic-1rosa13-x86_64] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: WD Blue / Red / Green SSDs
Device Model: WDC WDS200T2G0A-00JH30
Serial Number: --
LU WWN Device Id: 5 001b44 ...
Firmware Version: UP450400
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic
Device is: In smartctl database 7.5/5706
ATA Version is: ACS-3, ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Aug 10 16:11:28 2025 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x11) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 255) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct -O--CK 100 100 000 - 1
9 Power_On_Hours -O--CK 100 100 000 - 468
12 Power_Cycle_Count -O--CK 100 100 000 - 638
165 Block_Erase_Count -O--CK 100 100 000 - 984
166 Minimum_PE_Cycles_TLC -O--CK 100 100 --- - 6
167 Max_Bad_Blocks_per_Die -O--CK 100 100 --- - 47
168 Maximum_PE_Cycles_TLC -O--CK 100 100 --- - 8
169 Total_Bad_Blocks -O--CK 100 100 --- - 867
170 Grown_Bad_Blocks -O--CK 100 100 --- - 1
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Average_PE_Cycles_TLC -O--CK 100 100 000 - 6
174 Unexpected_Power_Loss -O--CK 100 100 000 - 122
184 End-to-End_Error -O--CK 100 100 --- - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 100 --- - 0
194 Temperature_Celsius -O---K 067 066 000 - 33 (Min/Max 15/66)
199 UDMA_CRC_Error_Count -O--CK 100 100 --- - 0
230 Media_Wearout_Indicator -O--CK 100 100 000 - 0x025101140251
232 Available_Reservd_Space PO--CK 100 100 005 - 99
233 NAND_GB_Written_TLC -O--CK 100 100 --- - 13249
234 NAND_GB_Written_SLC -O--CK 100 100 000 - 26587
241 Host_Writes_GiB ----CK 100 100 000 - 12215
242 Host_Reads_GiB ----CK 100 100 000 - 9631
244 Temp_Throttle_Status -O--CK 000 100 --- - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 16 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 1 Device vendor specific log
0xa2 GPL,SL VS 2 Device vendor specific log
0xa3-0xa4 GPL,SL VS 1 Device vendor specific log
0xa7 GPL,SL VS 1 Device vendor specific log
0xa9 GPL,SL VS 4 Device vendor specific log
Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum.
SMART Extended Comprehensive Error Log Version: 1 (16 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 371 -
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 638 --- Lifetime Power-On Resets
0x01 0x010 4 468 --- Power-on Hours
0x01 0x018 6 25618704436 --- Logical Sectors Written
0x01 0x028 6 20198802166 --- Logical Sectors Read
0x01 0x038 6 469 --- Date and Time TimeStamp
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 33 --- Current Temperature
0x05 0x010 1 - --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 67 --- Highest Temperature
0x05 0x028 1 23 --- Lowest Temperature
0x05 0x030 1 38 --- Highest Average Short Term Temperature
0x05 0x038 1 38 --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 95 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 1 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 77 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0001 2 0 Command failed due to ICRC error
/dev/sdb
smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.12.34-generic-1rosa13-x86_64] (local build)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: KINGSTON SFYRS1000G
Serial Number: --
Firmware Version: EIFK31.7
PCI Vendor/Subsystem ID: 0x2646
IEEE OUI Identifier: 0x0026b7
Total NVM Capacity: 1,000,204,886,016 [1.00 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,000,204,886,016 [1.00 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 0026b7 ...
Local Time is: Sun Aug 10 16:11:28 2025 MSK
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 84 Celsius
Critical Comp. Temp. Threshold: 89 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 8.80W - - 0 0 0 0 0 0
1 + 7.10W - - 1 1 1 1 0 0
2 + 5.20W - - 2 2 2 2 0 0
3 - 0.0620W - - 3 3 3 3 2500 7500
4 - 0.0620W - - 4 4 4 4 2500 7500
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02, NSID 0xffffffff)
Critical Warning: 0x00
Temperature: 45 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 2%
Data Units Read: 39,215,171 [20.0 TB]
Data Units Written: 42,620,258 [21.8 TB]
Host Read Commands: 330,112,657
Host Write Commands: 361,522,184
Controller Busy Time: 688
Power Cycles: 1,220
Power On Hours: 815
Unsafe Shutdowns: 569
Media and Data Integrity Errors: 0
Error Information Log Entries: 18,157
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 2: 76 Celsius
Thermal Temp. 1 Total Time: 14964
Warning: NVMe Get Log truncated to 0x200 bytes, 0x200 bytes zero filled
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Warning: NVMe Get Log truncated to 0x200 bytes, 0x034 bytes zero filled
Self-test Log (NVMe Log 0x06, NSID 0xffffffff)
Self-test status: No self-test in progress
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
0 Short Completed without error 807 - - - - -