Probe #3d12f00702 of Gigabyte GA-870A-UD3 Desktop Computer

Log: smartctl

/dev/sda smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.9.7-200.fc40.x86_64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Samsung based SSDs Device Model: Samsung SSD 850 EVO 250GB Serial Number: -- LU WWN Device Id: 5 002538 ... Firmware Version: EMT02B6Q User Capacity: 250,059,350,016 bytes [250 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available Device is: In smartctl database 7.3/5528 ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sat Jul 6 10:20:53 2024 AEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 133) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0 9 Power_On_Hours -O--CK 097 097 000 - 12026 12 Power_Cycle_Count -O--CK 099 099 000 - 290 177 Wear_Leveling_Count PO--C- 098 098 000 - 22 179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0 181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0 182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0 183 Runtime_Bad_Block PO--C- 100 099 010 - 0 187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O--CK 082 053 000 - 18 195 ECC_Error_Rate -O-RC- 200 200 000 - 0 199 CRC_Error_Count -OSRCK 099 099 000 - 7 235 POR_Recovery_Count -O--C- 099 099 000 - 26 241 Total_LBAs_Written -O--CK 099 099 000 - 13418881780 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 SL VS 16 Device vendor specific log 0xa5 SL VS 16 Device vendor specific log 0xce SL VS 16 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 11264 - # 2 Extended offline Completed without error 00% 10766 - # 3 Extended offline Completed without error 00% 10054 - # 4 Extended offline Completed without error 00% 9311 - # 5 Extended offline Completed without error 00% 8591 - # 6 Extended offline Completed without error 00% 7847 - # 7 Extended offline Completed without error 00% 7103 - # 8 Extended offline Completed without error 00% 6383 - # 9 Extended offline Completed without error 00% 5639 - #10 Extended offline Completed without error 00% 4919 - #11 Extended offline Completed without error 00% 4174 - #12 Extended offline Completed without error 00% 3502 - #13 Extended offline Completed without error 00% 2759 - #14 Extended offline Completed without error 00% 2016 - #15 Extended offline Completed without error 00% 1296 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing 255 0 65535 Read_scanning was never started Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) Device State: Active (0) Current Temperature: 19 Celsius Power Cycle Min/Max Temperature: 18/19 Celsius Lifetime Min/Max Temperature: 17/40 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: 0/70 Celsius Min/Max Temperature Limit: 0/70 Celsius Temperature History Size (Index): 128 (111) Index Estimated Time Temperature Celsius 112 2024-07-05 13:10 23 **** ... ..( 26 skipped). .. **** 11 2024-07-05 17:40 23 **** 12 2024-07-05 17:50 ? - 13 2024-07-05 18:00 20 * 14 2024-07-05 18:10 21 ** ... ..( 9 skipped). .. ** 24 2024-07-05 19:50 21 ** 25 2024-07-05 20:00 22 *** ... ..( 2 skipped). .. *** 28 2024-07-05 20:30 22 *** 29 2024-07-05 20:40 21 ** 30 2024-07-05 20:50 22 *** ... ..( 9 skipped). .. *** 40 2024-07-05 22:30 22 *** 41 2024-07-05 22:40 21 ** 42 2024-07-05 22:50 22 *** ... ..( 17 skipped). .. *** 60 2024-07-06 01:50 22 *** 61 2024-07-06 02:00 ? - 62 2024-07-06 02:10 19 - 63 2024-07-06 02:20 20 * ... ..( 20 skipped). .. * 84 2024-07-06 05:50 20 * 85 2024-07-06 06:00 21 ** 86 2024-07-06 06:10 21 ** 87 2024-07-06 06:20 20 * 88 2024-07-06 06:30 20 * 89 2024-07-06 06:40 20 * 90 2024-07-06 06:50 21 ** 91 2024-07-06 07:00 20 * ... ..( 9 skipped). .. * 101 2024-07-06 08:40 20 * 102 2024-07-06 08:50 18 - 103 2024-07-06 09:00 18 - 104 2024-07-06 09:10 ? - 105 2024-07-06 09:20 17 - 106 2024-07-06 09:30 18 - 107 2024-07-06 09:40 18 - 108 2024-07-06 09:50 19 - 109 2024-07-06 10:00 18 - 110 2024-07-06 10:10 ? - 111 2024-07-06 10:20 19 - SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 47 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 9 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC /dev/sdb smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.9.7-200.fc40.x86_64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.11 Device Model: ST31000333AS Serial Number: -- LU WWN Device Id: 5 000c50 ... Firmware Version: CC1H User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database 7.3/5528 ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Sat Jul 6 10:20:54 2024 AEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM level is: 0 (vendor specific), recommended: 254 APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Unknown === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 625) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 216) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x103f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 117 099 006 - 130131476 3 Spin_Up_Time PO---- 100 094 000 - 0 4 Start_Stop_Count -O--CK 100 100 020 - 836 5 Reallocated_Sector_Ct PO--CK 100 100 036 - 4 7 Seek_Error_Rate POSR-- 071 060 030 - 13687415 9 Power_On_Hours -O--CK 097 097 000 - 2896 10 Spin_Retry_Count PO--C- 100 100 097 - 1 12 Power_Cycle_Count -O--CK 100 100 020 - 716 184 End-to-End_Error -O--CK 100 100 099 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 099 000 - 65537 189 High_Fly_Writes -O-RCK 035 035 000 - 65 190 Airflow_Temperature_Cel -O---K 078 062 045 - 22 (Min/Max 16/22) 194 Temperature_Celsius -O---K 022 040 000 - 22 (0 14 0 0 0) 195 Hardware_ECC_Recovered -O-RC- 054 029 000 - 130131476 197 Current_Pending_Sector -O--C- 100 100 000 - 0 198 Offline_Uncorrectable ----C- 100 100 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 37 240 Head_Flying_Hours ------ 100 253 000 - 2893 (83 159 0) 241 Total_LBAs_Written ------ 100 253 000 - 4036280616 242 Total_LBAs_Read ------ 100 253 000 - 2791485577 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 GPL,SL R/O 1 Summary SMART error log 0x02 GPL,SL R/O 5 Comprehensive SMART error log 0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log 0x06 GPL,SL R/O 1 SMART self-test log 0x07 GPL,SL R/O 1 Extended self-test log 0x09 GPL,SL R/W 1 Selective self-test log 0x10 GPL,SL R/O 1 NCQ Command Error log 0x11 GPL,SL R/O 1 SATA Phy Event Counters log 0x21 GPL,SL R/O 1 Write stream error log 0x22 GPL,SL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 GPL,SL VS 20 Device vendor specific log 0xa2 GPL VS 2248 Device vendor specific log 0xa8 GPL,SL VS 129 Device vendor specific log 0xa9 GPL,SL VS 1 Device vendor specific log 0xb0 GPL VS 2928 Device vendor specific log 0xbe-0xbf GPL VS 65535 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (5 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 2634 - # 2 Extended offline Completed without error 00% 2583 - # 3 Extended offline Completed without error 00% 2138 - # 4 Extended offline Completed without error 00% 1653 - # 5 Extended offline Completed without error 00% 1640 - # 6 Extended offline Completed without error 00% 540 - # 7 Extended offline Completed without error 00% 468 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 522 (0x020a) Device State: Active (0) Current Temperature: 22 Celsius Power Cycle Min/Max Temperature: 16/22 Celsius Lifetime Min/Max Temperature: 14/38 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 14/55 Celsius Min/Max Temperature Limit: 10/60 Celsius Temperature History Size (Index): 128 (62) Index Estimated Time Temperature Celsius 63 2024-07-06 08:13 24 ***** ... ..( 35 skipped). .. ***** 99 2024-07-06 08:49 24 ***** 100 2024-07-06 08:50 23 **** ... ..( 16 skipped). .. **** 117 2024-07-06 09:07 23 **** 118 2024-07-06 09:08 ? - 119 2024-07-06 09:09 16 - 120 2024-07-06 09:10 17 - 121 2024-07-06 09:11 18 - 122 2024-07-06 09:12 18 - 123 2024-07-06 09:13 19 - 124 2024-07-06 09:14 20 * 125 2024-07-06 09:15 20 * 126 2024-07-06 09:16 21 ** 127 2024-07-06 09:17 21 ** 0 2024-07-06 09:18 21 ** 1 2024-07-06 09:19 22 *** 2 2024-07-06 09:20 22 *** 3 2024-07-06 09:21 22 *** 4 2024-07-06 09:22 23 **** ... ..( 3 skipped). .. **** 8 2024-07-06 09:26 23 **** 9 2024-07-06 09:27 24 ***** ... ..( 7 skipped). .. ***** 17 2024-07-06 09:35 24 ***** 18 2024-07-06 09:36 25 ****** ... ..( 7 skipped). .. ****** 26 2024-07-06 09:44 25 ****** 27 2024-07-06 09:45 24 ***** ... ..( 20 skipped). .. ***** 48 2024-07-06 10:06 24 ***** 49 2024-07-06 10:07 ? - 50 2024-07-06 10:08 16 - 51 2024-07-06 10:09 17 - 52 2024-07-06 10:10 17 - 53 2024-07-06 10:11 18 - 54 2024-07-06 10:12 19 - 55 2024-07-06 10:13 19 - 56 2024-07-06 10:14 20 * 57 2024-07-06 10:15 20 * 58 2024-07-06 10:16 20 * 59 2024-07-06 10:17 21 ** 60 2024-07-06 10:18 21 ** 61 2024-07-06 10:19 21 ** 62 2024-07-06 10:20 22 *** SCT Error Recovery Control: Read: 70 (7.0 seconds) Write: 70 (7.0 seconds) Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x000a 2 6 Device-to-host register FISes sent due to a COMRESET 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS /dev/sdc smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.9.7-200.fc40.x86_64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.11 Device Model: ST31000333AS Serial Number: -- LU WWN Device Id: 5 000c50 ... Firmware Version: CC1H User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database 7.3/5528 ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Sat Jul 6 10:20:54 2024 AEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM level is: 254 (maximum performance), recommended: 254 APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Unknown === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 617) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 207) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x103f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 120 099 006 - 241978525 3 Spin_Up_Time PO---- 100 094 000 - 0 4 Start_Stop_Count -O--CK 100 100 020 - 919 5 Reallocated_Sector_Ct PO--CK 098 098 036 - 97 7 Seek_Error_Rate POSR-- 075 060 030 - 37415738 9 Power_On_Hours -O--CK 086 086 000 - 12911 10 Spin_Retry_Count PO--C- 100 100 097 - 0 12 Power_Cycle_Count -O--CK 100 100 020 - 792 184 End-to-End_Error -O--CK 100 100 099 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 099 000 - 8590065668 189 High_Fly_Writes -O-RCK 001 001 000 - 141 190 Airflow_Temperature_Cel -O---K 077 059 045 - 23 (Min/Max 17/23) 194 Temperature_Celsius -O---K 023 041 000 - 23 (0 15 0 0 0) 195 Hardware_ECC_Recovered -O-RC- 058 030 000 - 241978525 197 Current_Pending_Sector -O--C- 100 100 000 - 0 198 Offline_Uncorrectable ----C- 100 100 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0 240 Head_Flying_Hours ------ 100 253 000 - 12911 (13 236 0) 241 Total_LBAs_Written ------ 100 253 000 - 2494143955 242 Total_LBAs_Read ------ 100 253 000 - 1811876988 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 GPL,SL R/O 1 Summary SMART error log 0x02 GPL,SL R/O 5 Comprehensive SMART error log 0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log 0x06 GPL,SL R/O 1 SMART self-test log 0x07 GPL,SL R/O 1 Extended self-test log 0x09 GPL,SL R/W 1 Selective self-test log 0x10 GPL,SL R/O 1 NCQ Command Error log 0x11 GPL,SL R/O 1 SATA Phy Event Counters log 0x21 GPL,SL R/O 1 Write stream error log 0x22 GPL,SL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 GPL,SL VS 20 Device vendor specific log 0xa2 GPL VS 2248 Device vendor specific log 0xa8 GPL,SL VS 129 Device vendor specific log 0xa9 GPL,SL VS 1 Device vendor specific log 0xb0 GPL VS 2928 Device vendor specific log 0xbe-0xbf GPL VS 65535 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (5 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 12649 - # 2 Extended offline Completed without error 00% 12597 - # 3 Extended offline Completed without error 00% 12152 - # 4 Short offline Completed without error 00% 11953 - # 5 Extended offline Completed without error 00% 11668 - # 6 Extended offline Completed without error 00% 11657 - # 7 Extended offline Completed without error 00% 10989 - # 8 Extended offline Completed without error 00% 10246 - # 9 Extended offline Completed without error 00% 9526 - #10 Extended offline Completed without error 00% 8782 - #11 Extended offline Completed without error 00% 8038 - #12 Extended offline Completed without error 00% 7318 - #13 Extended offline Completed without error 00% 6574 - #14 Extended offline Completed without error 00% 5854 - #15 Extended offline Completed without error 00% 5109 - #16 Extended offline Completed without error 00% 4436 - #17 Extended offline Completed without error 00% 3694 - #18 Extended offline Completed without error 00% 2950 - #19 Extended offline Completed without error 00% 2230 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 522 (0x020a) Device State: Active (0) Current Temperature: 23 Celsius Power Cycle Min/Max Temperature: 17/23 Celsius Lifetime Min/Max Temperature: 15/41 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 14/55 Celsius Min/Max Temperature Limit: 10/60 Celsius Temperature History Size (Index): 128 (66) Index Estimated Time Temperature Celsius 67 2024-07-06 08:13 24 ***** ... ..( 19 skipped). .. ***** 87 2024-07-06 08:33 24 ***** 88 2024-07-06 08:34 25 ****** 89 2024-07-06 08:35 24 ***** 90 2024-07-06 08:36 25 ****** ... ..( 2 skipped). .. ****** 93 2024-07-06 08:39 25 ****** 94 2024-07-06 08:40 24 ***** ... ..( 26 skipped). .. ***** 121 2024-07-06 09:07 24 ***** 122 2024-07-06 09:08 ? - 123 2024-07-06 09:09 17 - 124 2024-07-06 09:10 18 - 125 2024-07-06 09:11 19 - 126 2024-07-06 09:12 19 - 127 2024-07-06 09:13 20 * 0 2024-07-06 09:14 21 ** 1 2024-07-06 09:15 21 ** 2 2024-07-06 09:16 22 *** 3 2024-07-06 09:17 22 *** 4 2024-07-06 09:18 23 **** 5 2024-07-06 09:19 23 **** 6 2024-07-06 09:20 23 **** 7 2024-07-06 09:21 24 ***** ... ..( 2 skipped). .. ***** 10 2024-07-06 09:24 24 ***** 11 2024-07-06 09:25 25 ****** ... ..( 6 skipped). .. ****** 18 2024-07-06 09:32 25 ****** 19 2024-07-06 09:33 26 ******* ... ..( 11 skipped). .. ******* 31 2024-07-06 09:45 26 ******* 32 2024-07-06 09:46 25 ****** ... ..( 19 skipped). .. ****** 52 2024-07-06 10:06 25 ****** 53 2024-07-06 10:07 ? - 54 2024-07-06 10:08 17 - 55 2024-07-06 10:09 18 - 56 2024-07-06 10:10 18 - 57 2024-07-06 10:11 19 - 58 2024-07-06 10:12 20 * 59 2024-07-06 10:13 20 * 60 2024-07-06 10:14 21 ** 61 2024-07-06 10:15 21 ** 62 2024-07-06 10:16 21 ** 63 2024-07-06 10:17 22 *** 64 2024-07-06 10:18 22 *** 65 2024-07-06 10:19 22 *** 66 2024-07-06 10:20 23 **** SCT Error Recovery Control: Read: 70 (7.0 seconds) Write: 70 (7.0 seconds) Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x000a 2 6 Device-to-host register FISes sent due to a COMRESET 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS /dev/sdd smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.9.7-200.fc40.x86_64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Samsung based SSDs Device Model: Samsung SSD 840 EVO 250GB Serial Number: -- LU WWN Device Id: 5 002538 ... Firmware Version: EXT0DB6Q User Capacity: 250,059,350,016 bytes [250 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device TRIM Command: Available Device is: In smartctl database 7.3/5528 ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sat Jul 6 10:20:54 2024 AEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Unexpected SCT status 0x0001 (action_code=4, function_code=2) Wt Cache Reorder: Unknown (SCT Feature Control command failed) === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 4800) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 80) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0 9 Power_On_Hours -O--CK 095 095 000 - 21035 12 Power_Cycle_Count -O--CK 099 099 000 - 698 177 Wear_Leveling_Count PO--C- 099 099 000 - 10 179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0 181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0 182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0 183 Runtime_Bad_Block PO--C- 100 100 010 - 0 187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O--CK 077 045 000 - 23 195 ECC_Error_Rate -O-RC- 200 200 000 - 0 199 CRC_Error_Count -OSRCK 099 099 000 - 16 235 POR_Recovery_Count -O--C- 099 099 000 - 79 241 Total_LBAs_Written -O--CK 099 099 000 - 7617910096 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 GPL,SL VS 16 Device vendor specific log 0xce GPL,SL VS 16 Device vendor specific log 0xde SL VS 1 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 1 - # 2 Extended offline Interrupted (host reset) 00% 0 - # 3 Short offline Completed without error 00% 0 - # 4 Extended offline Completed without error 00% 479 - # 5 Extended offline Completed without error 00% 16 - # 6 Extended offline Completed without error 00% 3 - # 7 Extended offline Completed without error 00% 1 - # 8 Extended offline Completed without error 00% 0 - # 9 Extended offline Completed without error 00% 491 - #10 Extended offline Completed without error 00% 5119 - #11 Extended offline Completed without error 00% 3206 - #12 Extended offline Completed without error 00% 2462 - #13 Extended offline Completed without error 00% 525 - #14 Extended offline Completed without error 00% 5735 - #15 Extended offline Completed without error 00% 4991 - #16 Extended offline Completed without error 00% 3078 - #17 Extended offline Completed without error 00% 1140 - #18 Extended offline Completed without error 00% 468 - #19 Extended offline Completed without error 00% 455 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 1 (0x0001) Device State: Active (0) Current Temperature: 23 Celsius Power Cycle Min/Max Temperature: ?/ ? Celsius Lifetime Min/Max Temperature: ?/ ? Celsius Under/Over Temperature Limit Count: 0/90761 SCT Temperature History Version: 2 Temperature Sampling Period: 10 minutes Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: ?/ ? Celsius Min/Max Temperature Limit: ?/ ? Celsius Temperature History Size (Index): 128 (1) Index Estimated Time Temperature Celsius 2 2024-07-05 13:10 ? - ... ..(125 skipped). .. - 0 2024-07-06 10:10 ? - 1 2024-07-06 10:20 23 **** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 733 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 8 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC /dev/sde smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.9.7-200.fc40.x86_64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint F1 DT Device Model: SAMSUNG HD103UJ Serial Number: -- LU WWN Device Id: 5 0024e9 ... Firmware Version: 1AA01118 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database 7.3/5528 ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b Local Time is: Sat Jul 6 10:20:54 2024 AEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM level is: 254 (maximum performance), recommended: 254 APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (14134) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 236) minutes. Conveyance self-test routine recommended polling time: ( 25) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0 3 Spin_Up_Time POS--- 068 068 011 - 10500 4 Start_Stop_Count -O--CK 099 099 000 - 562 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0 7 Seek_Error_Rate POSR-- 100 100 051 - 0 8 Seek_Time_Performance P-S--K 100 100 015 - 10448 9 Power_On_Hours -O--CK 098 098 000 - 11836 10 Spin_Retry_Count PO--CK 100 100 051 - 0 11 Calibration_Retry_Count -O--C- 100 100 000 - 0 12 Power_Cycle_Count -O--CK 099 099 000 - 509 13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 0 183 Runtime_Bad_Block -O--CK 100 100 000 - 0 184 End-to-End_Error PO--CK 100 100 000 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O---K 089 066 000 - 11 (Min/Max 11/11) 194 Temperature_Celsius -O---K 084 065 000 - 16 (Min/Max 11/16) 195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 4343 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O--C- 100 100 000 - 0 198 Offline_Uncorrectable ----CK 100 100 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 100 099 000 - 149 200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0 201 Soft_Read_Error_Rate -O-R-- 253 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 2 Comprehensive SMART error log 0x03 GPL R/O 2 Ext. Comprehensive SMART error log 0x04 GPL R/O 2 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 2 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x20 GPL R/O 2 Streaming performance log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (2 sectors) Device Error Count: 149 (device log contains only the most recent 8 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 149 [4] occurred at disk power-on lifetime: 456 hours (19 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 00 1f 00 00 61 12 42 78 40 00 Error: ICRC, ABRT 31 sectors at LBA = 0x61124278 = 1628586616 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 80 00 00 61 12 42 17 40 00 08:38:20.400 READ DMA EXT 25 00 00 00 80 00 00 61 12 41 97 40 00 08:38:20.400 READ DMA EXT 25 00 00 00 80 00 00 61 12 41 17 40 00 08:38:20.400 READ DMA EXT 25 00 00 00 80 00 00 61 12 40 97 40 00 08:38:20.400 READ DMA EXT 25 00 00 00 80 00 00 61 12 40 17 40 00 08:38:20.400 READ DMA EXT Error 148 [3] occurred at disk power-on lifetime: 456 hours (19 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 00 5f 00 00 00 60 1c c0 40 00 Error: ICRC, ABRT 95 sectors at LBA = 0x00601cc0 = 6298816 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 80 00 00 00 60 1c 9f 40 00 08:31:56.730 READ DMA 25 00 00 00 08 00 00 29 6a ff 3f 40 00 08:31:56.720 READ DMA EXT ca 00 00 00 80 00 00 00 60 1c 17 40 00 08:31:56.720 WRITE DMA 35 00 00 00 20 00 00 47 0f b6 7f 40 00 08:31:56.720 WRITE DMA EXT 35 00 00 00 80 00 00 47 10 1c df 40 00 08:31:56.720 WRITE DMA EXT Error 147 [2] occurred at disk power-on lifetime: 456 hours (19 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 00 3f 00 00 00 60 09 60 40 00 Error: ICRC, ABRT 63 sectors at LBA = 0x00600960 = 6293856 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 80 00 00 00 60 09 1f 40 00 08:31:31.660 READ DMA 25 00 00 00 08 00 00 29 bd 76 97 40 00 08:31:31.600 READ DMA EXT c8 00 00 00 08 00 00 00 60 1c 9f 40 00 08:31:31.590 READ DMA c8 00 00 00 08 00 00 00 60 1c 97 40 00 08:31:31.580 READ DMA c8 00 00 00 08 00 00 00 60 1c 8f 40 00 08:31:31.560 READ DMA Error 146 [1] occurred at disk power-on lifetime: 456 hours (19 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 00 -- d0 00 08 00 00 29 1e 70 cf 40 00 8 sectors at LBA = 0x291e70cf = 689860815 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 40 00 00 00 60 2e df 40 00 08:31:21.670 READ DMA ca 00 00 00 08 00 00 00 60 2e cf 40 00 08:31:21.670 WRITE DMA 35 00 00 00 20 00 00 47 0f b6 7f 40 00 08:31:21.670 WRITE DMA EXT 35 00 00 00 20 00 00 47 0f f7 9f 40 00 08:31:21.670 WRITE DMA EXT c8 00 00 00 20 00 00 00 60 2e bf 40 00 08:31:21.670 READ DMA Error 145 [0] occurred at disk power-on lifetime: 456 hours (19 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 00 40 00 00 47 0f f5 bf 40 00 Error: ICRC, ABRT 64 sectors at LBA = 0x470ff5bf = 1192228287 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 35 00 00 00 40 00 00 47 0f f5 bf 40 00 08:31:18.680 WRITE DMA EXT c8 00 00 00 40 00 00 00 60 01 9f 40 00 08:31:18.680 READ DMA ca 00 00 00 10 00 00 00 60 01 6f 40 00 08:31:18.680 WRITE DMA 35 00 00 00 20 00 00 47 0f b6 7f 40 00 08:31:18.680 WRITE DMA EXT 35 00 00 00 20 00 00 47 0f f5 9f 40 00 08:31:18.680 WRITE DMA EXT Error 144 [7] occurred at disk power-on lifetime: 456 hours (19 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 00 1a 00 00 47 0f f5 05 40 00 Error: ICRC, ABRT 26 sectors at LBA = 0x470ff505 = 1192228101 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 35 00 00 00 20 00 00 47 0f f4 ff 40 00 08:31:16.660 WRITE DMA EXT 35 00 00 00 20 00 00 47 0f f4 ff 40 00 08:31:15.660 WRITE DMA EXT 25 00 00 00 20 00 00 3a 38 9c 1f 40 00 08:31:15.660 READ DMA EXT 35 00 00 00 08 00 00 3a 38 0d df 40 00 08:31:15.660 WRITE DMA EXT ca 00 00 00 08 00 00 00 5e 00 3f 40 00 08:31:15.620 WRITE DMA Error 143 [6] occurred at disk power-on lifetime: 456 hours (19 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 00 37 00 00 44 58 71 f8 40 00 Error: ICRC, ABRT 55 sectors at LBA = 0x445871f8 = 1146647032 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 78 00 00 44 58 71 b7 40 00 08:18:55.200 READ DMA EXT 25 00 00 00 40 00 00 44 58 71 77 40 00 08:18:55.190 READ DMA EXT 25 00 00 00 38 00 00 44 58 71 3f 40 00 08:18:55.190 READ DMA EXT 25 00 00 00 78 00 00 44 58 70 c7 40 00 08:18:55.190 READ DMA EXT 25 00 00 00 78 00 00 44 58 70 4f 40 00 08:18:55.190 READ DMA EXT Error 142 [5] occurred at disk power-on lifetime: 456 hours (19 days + 0 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 00 1f 00 00 00 60 16 20 40 00 Error: ICRC, ABRT 31 sectors at LBA = 0x00601620 = 6297120 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 80 00 00 00 60 15 bf 40 00 08:18:40.050 READ DMA 25 00 00 00 78 00 00 44 58 40 f7 40 00 08:18:40.050 READ DMA EXT c8 00 00 00 80 00 00 00 60 15 3f 40 00 08:18:40.050 READ DMA 25 00 00 00 78 00 00 44 58 40 7f 40 00 08:18:40.050 READ DMA EXT c8 00 00 00 80 00 00 00 60 14 bf 40 00 08:18:40.050 READ DMA SMART Extended Self-test Log Version: 1 (2 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 9921 - # 2 Short offline Completed without error 00% 11580 - # 3 Extended offline Completed without error 00% 9178 - # 4 Extended offline Completed without error 00% 11084 - # 5 Extended offline Completed without error 00% 8458 - # 6 Extended offline Completed without error 00% 7714 - # 7 Extended offline Completed without error 00% 6970 - # 8 Extended offline Completed without error 00% 10599 - # 9 Extended offline Completed without error 00% 10589 - #10 Extended offline Aborted by host 80% 10579 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 256 (0x0100) Device State: Active (0) Current Temperature: 16 Celsius Power Cycle Min/Max Temperature: --/16 Celsius Lifetime Min/Max Temperature: --/35 Celsius SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: -4/72 Celsius Min/Max Temperature Limit: -9/77 Celsius Temperature History Size (Index): 128 (54) Index Estimated Time Temperature Celsius 55 2024-07-06 08:13 18 - ... ..( 34 skipped). .. - 90 2024-07-06 08:48 18 - 91 2024-07-06 08:49 11 - ... ..( 3 skipped). .. - 95 2024-07-06 08:53 11 - 96 2024-07-06 08:54 12 - 97 2024-07-06 08:55 12 - 98 2024-07-06 08:56 13 - 99 2024-07-06 08:57 14 - 100 2024-07-06 08:58 15 - 101 2024-07-06 08:59 15 - 102 2024-07-06 09:00 16 - 103 2024-07-06 09:01 16 - 104 2024-07-06 09:02 17 - 105 2024-07-06 09:03 17 - 106 2024-07-06 09:04 17 - 107 2024-07-06 09:05 18 - ... ..( 2 skipped). .. - 110 2024-07-06 09:08 18 - 111 2024-07-06 09:09 19 - ... ..( 5 skipped). .. - 117 2024-07-06 09:15 19 - 118 2024-07-06 09:16 20 * ... ..( 10 skipped). .. * 1 2024-07-06 09:27 20 * 2 2024-07-06 09:28 19 - ... ..( 2 skipped). .. - 5 2024-07-06 09:31 19 - 6 2024-07-06 09:32 20 * 7 2024-07-06 09:33 19 - ... ..( 18 skipped). .. - 26 2024-07-06 09:52 19 - 27 2024-07-06 09:53 18 - 28 2024-07-06 09:54 19 - 29 2024-07-06 09:55 19 - 30 2024-07-06 09:56 19 - 31 2024-07-06 09:57 11 - ... ..( 4 skipped). .. - 36 2024-07-06 10:02 11 - 37 2024-07-06 10:03 12 - 38 2024-07-06 10:04 13 - 39 2024-07-06 10:05 13 - 40 2024-07-06 10:06 14 - 41 2024-07-06 10:07 14 - 42 2024-07-06 10:08 15 - 43 2024-07-06 10:09 15 - 44 2024-07-06 10:10 15 - 45 2024-07-06 10:11 16 - ... ..( 8 skipped). .. - 54 2024-07-06 10:20 16 - SCT Error Recovery Control: Read: 70 (7.0 seconds) Write: 70 (7.0 seconds) ATA_READ_LOG_EXT (addr=0x04:0x00, page=0, n=1) failed: scsi error badly formed scsi parameters Read Device Statistics page 0x00 failed Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x000a 2 5 Device-to-host register FISes sent due to a COMRESET 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 564 Transition from drive PhyRdy to drive PhyNRdy 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC /dev/sdf smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.9.7-200.fc40.x86_64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint F1 DT Device Model: SAMSUNG HD103UJ Serial Number: -- LU WWN Device Id: 5 0024e9 ... Firmware Version: 1AA01118 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database 7.3/5528 ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b Local Time is: Sat Jul 6 10:20:54 2024 AEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (14225) seconds. Offline data collection capabilities: (0x7f) SMART execute Offline immediate. Auto Offline data collection on/off support. Abort Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 238) minutes. Conveyance self-test routine recommended polling time: ( 25) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0 3 Spin_Up_Time POS--- 065 065 011 - 11340 4 Start_Stop_Count -O--CK 099 099 000 - 833 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0 7 Seek_Error_Rate POSR-- 253 253 051 - 0 8 Seek_Time_Performance P-S--K 100 100 015 - 10418 9 Power_On_Hours -O--CK 099 099 000 - 2767 10 Spin_Retry_Count PO--CK 100 100 051 - 0 11 Calibration_Retry_Count -O--C- 100 100 000 - 0 12 Power_Cycle_Count -O--CK 099 099 000 - 730 13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 0 183 Runtime_Bad_Block -O--CK 100 100 000 - 0 184 End-to-End_Error PO--CK 001 001 000 - 150 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O---K 091 071 000 - 9 (Min/Max 9/9) 194 Temperature_Celsius -O---K 086 070 000 - 14 (Min/Max 9/14) 195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 1263 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O--C- 100 100 000 - 0 198 Offline_Uncorrectable ----CK 100 100 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 100 100 000 - 1626 200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 1 201 Soft_Read_Error_Rate -O-R-- 253 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 2 Comprehensive SMART error log 0x03 GPL R/O 2 Ext. Comprehensive SMART error log 0x04 GPL R/O 2 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 2 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x20 GPL R/O 2 Streaming performance log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (2 sectors) Device Error Count: 1626 (device log contains only the most recent 8 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 1626 [1] occurred at disk power-on lifetime: 563 hours (23 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 01 c1 00 00 00 06 6a 3f e0 00 Error: ICRC, ABRT 449 sectors at LBA = 0x00066a3f = 420415 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 35 00 00 04 00 00 00 00 06 68 00 e0 00 00:11:21.820 WRITE DMA EXT 35 00 00 04 00 00 00 00 06 64 00 e0 00 00:11:21.820 WRITE DMA EXT 27 00 00 00 00 00 00 00 00 00 00 e0 00 00:11:21.810 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 02 00:11:21.800 IDENTIFY DEVICE ef 00 03 00 42 00 00 00 00 00 00 a0 02 00:11:21.800 SET FEATURES [Set transfer mode] Error 1625 [0] occurred at disk power-on lifetime: 563 hours (23 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 00 -- 58 00 f7 00 00 00 06 67 09 e0 00 247 sectors at LBA = 0x00066709 = 419593 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 35 00 00 04 00 00 00 00 06 64 00 e0 00 00:10:51.350 WRITE DMA EXT 27 00 00 00 00 00 00 00 00 00 00 e0 00 00:10:51.350 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 02 00:10:51.330 IDENTIFY DEVICE ef 00 03 00 42 00 00 00 00 00 00 a0 02 00:10:51.330 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 00 00 00 00 00 e0 00 00:10:51.330 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] Error 1624 [7] occurred at disk power-on lifetime: 563 hours (23 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 03 f4 00 00 00 06 64 0c e0 00 Error: ICRC, ABRT 1012 sectors at LBA = 0x0006640c = 418828 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 35 00 00 04 00 00 00 00 06 64 00 e0 00 00:10:51.080 WRITE DMA EXT ea 00 00 00 00 00 00 00 06 63 ff a0 00 00:10:51.030 FLUSH CACHE EXT ea 00 00 00 00 00 00 00 06 63 ff a0 00 00:10:50.990 FLUSH CACHE EXT 35 00 00 04 00 00 00 00 06 60 00 e0 00 00:10:50.990 WRITE DMA EXT 27 00 00 00 00 00 00 00 00 00 00 e0 00 00:10:50.990 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] Error 1623 [6] occurred at disk power-on lifetime: 563 hours (23 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 02 b8 00 00 00 06 61 48 e0 00 Error: ICRC, ABRT 696 sectors at LBA = 0x00066148 = 418120 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 35 00 00 04 00 00 00 00 06 60 00 e0 00 00:10:45.250 WRITE DMA EXT 35 00 00 04 00 00 00 00 06 5c 00 e0 00 00:10:45.240 WRITE DMA EXT 27 00 00 00 00 00 00 00 00 00 00 e0 00 00:10:45.240 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 02 00:10:45.220 IDENTIFY DEVICE ef 00 03 00 42 00 00 00 00 00 00 a0 02 00:10:45.220 SET FEATURES [Set transfer mode] Error 1622 [5] occurred at disk power-on lifetime: 563 hours (23 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 04 00 00 00 00 06 5c 00 e0 00 Error: ICRC, ABRT 1024 sectors at LBA = 0x00065c00 = 416768 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 35 00 00 04 00 00 00 00 06 5c 00 e0 00 00:10:39.860 WRITE DMA EXT 35 00 00 04 00 00 00 00 06 54 00 e0 00 00:10:39.760 WRITE DMA EXT 35 00 00 04 00 00 00 00 06 58 00 e0 00 00:10:39.760 WRITE DMA EXT 27 00 00 00 00 00 00 00 00 00 00 e0 00 00:10:39.760 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 02 00:10:39.740 IDENTIFY DEVICE Error 1621 [4] occurred at disk power-on lifetime: 563 hours (23 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 00 -- 58 04 00 00 00 00 06 58 00 e0 00 1024 sectors at LBA = 0x00065800 = 415744 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 35 00 00 04 00 00 00 00 06 58 00 e0 00 00:10:39.570 WRITE DMA EXT ea 00 00 00 00 00 00 00 06 53 ff a0 00 00:10:39.480 FLUSH CACHE EXT ea 00 00 00 00 00 00 00 06 53 ff a0 00 00:10:39.440 FLUSH CACHE EXT 35 00 00 04 00 00 00 00 06 50 00 e0 00 00:10:39.440 WRITE DMA EXT 27 00 00 00 00 00 00 00 00 00 00 e0 00 00:10:39.440 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] Error 1620 [3] occurred at disk power-on lifetime: 563 hours (23 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 03 3c 00 00 00 06 50 c4 e0 00 Error: ICRC, ABRT 828 sectors at LBA = 0x000650c4 = 413892 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 35 00 00 04 00 00 00 00 06 50 00 e0 00 00:10:33.950 WRITE DMA EXT 35 00 00 04 00 00 00 00 06 4c 00 e0 00 00:10:33.940 WRITE DMA EXT 27 00 00 00 00 00 00 00 00 00 00 e0 00 00:10:33.940 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 02 00:10:33.920 IDENTIFY DEVICE ef 00 03 00 42 00 00 00 00 00 00 a0 02 00:10:33.920 SET FEATURES [Set transfer mode] Error 1619 [2] occurred at disk power-on lifetime: 563 hours (23 days + 11 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 84 -- 51 03 4a 00 00 00 06 4c b6 e0 00 Error: ICRC, ABRT 842 sectors at LBA = 0x00064cb6 = 412854 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 35 00 00 04 00 00 00 00 06 4c 00 e0 00 00:10:33.560 WRITE DMA EXT 27 00 00 00 00 00 00 00 00 00 00 e0 00 00:10:33.560 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 00 00 00 00 00 a0 02 00:10:33.540 IDENTIFY DEVICE ef 00 03 00 42 00 00 00 00 00 00 a0 02 00:10:33.540 SET FEATURES [Set transfer mode] 27 00 00 00 00 00 00 00 00 00 00 e0 00 00:10:33.540 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] SMART Extended Self-test Log Version: 1 (2 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Aborted by host 80% 1515 - # 2 Extended offline Completed without error 00% 2609 - # 3 Short offline Completed without error 00% 2597 - # 4 Extended offline Interrupted (host reset) 20% 588 - # 5 Extended offline Interrupted (host reset) 70% 561 - # 6 Extended offline Aborted by host 90% 560 - # 7 Extended offline Completed without error 00% 2020 - # 8 Extended offline Completed without error 00% 550 - # 9 Extended offline Interrupted (host reset) 50% 479 - #10 Extended offline Completed without error 00% 478 - #11 Extended offline Completed without error 00% 1535 - #12 Extended offline Completed without error 00% 1522 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 256 (0x0100) Device State: Active (0) Current Temperature: 14 Celsius Power Cycle Min/Max Temperature: --/14 Celsius Lifetime Min/Max Temperature: --/36 Celsius SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: -4/72 Celsius Min/Max Temperature Limit: -9/77 Celsius Temperature History Size (Index): 128 (8) Index Estimated Time Temperature Celsius 9 2024-07-06 08:13 16 - 10 2024-07-06 08:14 16 - 11 2024-07-06 08:15 16 - 12 2024-07-06 08:16 15 - 13 2024-07-06 08:17 15 - 14 2024-07-06 08:18 16 - ... ..( 45 skipped). .. - 60 2024-07-06 09:04 16 - 61 2024-07-06 09:05 9 - 62 2024-07-06 09:06 9 - 63 2024-07-06 09:07 10 - 64 2024-07-06 09:08 11 - 65 2024-07-06 09:09 11 - 66 2024-07-06 09:10 12 - 67 2024-07-06 09:11 12 - 68 2024-07-06 09:12 13 - ... ..( 2 skipped). .. - 71 2024-07-06 09:15 13 - 72 2024-07-06 09:16 14 - ... ..( 2 skipped). .. - 75 2024-07-06 09:19 14 - 76 2024-07-06 09:20 15 - ... ..( 7 skipped). .. - 84 2024-07-06 09:28 15 - 85 2024-07-06 09:29 16 - 86 2024-07-06 09:30 15 - 87 2024-07-06 09:31 15 - 88 2024-07-06 09:32 16 - ... ..( 31 skipped). .. - 120 2024-07-06 10:04 16 - 121 2024-07-06 10:05 9 - 122 2024-07-06 10:06 10 - 123 2024-07-06 10:07 10 - 124 2024-07-06 10:08 11 - 125 2024-07-06 10:09 11 - 126 2024-07-06 10:10 12 - 127 2024-07-06 10:11 12 - 0 2024-07-06 10:12 13 - 1 2024-07-06 10:13 13 - 2 2024-07-06 10:14 13 - 3 2024-07-06 10:15 14 - ... ..( 4 skipped). .. - 8 2024-07-06 10:20 14 - SCT Error Recovery Control: Read: Disabled Write: Disabled ATA_READ_LOG_EXT (addr=0x04:0x00, page=0, n=1) failed: scsi error badly formed scsi parameters Read Device Statistics page 0x00 failed Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x000a 2 5 Device-to-host register FISes sent due to a COMRESET 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 463 Transition from drive PhyRdy to drive PhyNRdy 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC /dev/sdg smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.9.7-200.fc40.x86_64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Barracuda Green (AF) Device Model: ST2000DL003-9VT166 Serial Number: -- LU WWN Device Id: 5 000c50 ... Firmware Version: CC32 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 5900 rpm Device is: In smartctl database 7.3/5528 ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 1.5 Gb/s) Local Time is: Sat Jul 6 10:20:55 2024 AEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM level is: 0 (vendor specific), recommended: 254 APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 612) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 333) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x30b7) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 113 099 006 - 56426296 3 Spin_Up_Time PO---- 092 092 000 - 0 4 Start_Stop_Count -O--CK 100 100 020 - 360 5 Reallocated_Sector_Ct PO--CK 100 100 036 - 8 7 Seek_Error_Rate POSR-- 074 060 030 - 28765169 9 Power_On_Hours -O--CK 087 087 000 - 12108 10 Spin_Retry_Count PO--C- 100 100 097 - 0 12 Power_Cycle_Count -O--CK 100 100 020 - 351 183 Runtime_Bad_Block -O--CK 100 100 000 - 0 184 End-to-End_Error -O--CK 100 100 099 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 076 000 - 8590065910 189 High_Fly_Writes -O-RCK 097 097 000 - 3 190 Airflow_Temperature_Cel -O---K 078 057 045 - 22 (Min/Max 18/22) 191 G-Sense_Error_Rate -O--CK 100 100 000 - 0 192 Power-Off_Retract_Count -O--CK 100 100 000 - 113 193 Load_Cycle_Count -O--CK 100 100 000 - 361 194 Temperature_Celsius -O---K 022 043 000 - 22 (0 16 0 0 0) 195 Hardware_ECC_Recovered -O-RC- 033 004 000 - 56426296 197 Current_Pending_Sector -O--C- 100 100 000 - 0 198 Offline_Uncorrectable ----C- 100 100 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 2805 240 Head_Flying_Hours ------ 100 253 000 - 12125 (239 158 0) 241 Total_LBAs_Written ------ 100 253 000 - 1178449956 242 Total_LBAs_Read ------ 100 253 000 - 4119880909 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 5 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 GPL,SL VS 20 Device vendor specific log 0xa2 GPL VS 2248 Device vendor specific log 0xa8 GPL,SL VS 20 Device vendor specific log 0xa9 GPL,SL VS 1 Device vendor specific log 0xab GPL VS 1 Device vendor specific log 0xb0 GPL VS 2819 Device vendor specific log 0xbd GPL VS 252 Device vendor specific log 0xbe-0xbf GPL VS 65535 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (5 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 11848 - # 2 Extended offline Completed without error 00% 11791 - # 3 Short offline Completed without error 00% 11775 - # 4 Extended offline Interrupted (host reset) 90% 10875 - # 5 Extended offline Interrupted (host reset) 90% 10857 - # 6 Short offline Interrupted (host reset) 10% 10853 - # 7 Extended offline Completed without error 00% 10202 - # 8 Extended offline Completed without error 00% 9459 - # 9 Extended offline Completed without error 00% 8739 - #10 Extended offline Completed without error 00% 7995 - #11 Extended offline Completed without error 00% 7251 - #12 Extended offline Completed without error 00% 6531 - #13 Extended offline Completed without error 00% 5787 - #14 Extended offline Completed without error 00% 5067 - #15 Extended offline Completed without error 00% 4322 - #16 Extended offline Completed without error 00% 3649 - #17 Extended offline Completed without error 00% 2907 - #18 Extended offline Completed without error 00% 2163 - #19 Extended offline Completed without error 00% 1443 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 522 (0x020a) Device State: Active (0) Current Temperature: 22 Celsius Power Cycle Min/Max Temperature: 18/22 Celsius Lifetime Min/Max Temperature: 16/43 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 59 minutes Min/Max recommended Temperature: 14/55 Celsius Min/Max Temperature Limit: 10/60 Celsius Temperature History Size (Index): 128 (101) Index Estimated Time Temperature Celsius 102 2024-07-01 05:08 25 ****** 103 2024-07-01 06:07 25 ****** 104 2024-07-01 07:06 34 *************** 105 2024-07-01 08:05 ? - 106 2024-07-01 09:04 27 ******** 107 2024-07-01 10:03 27 ******** 108 2024-07-01 11:02 ? - 109 2024-07-01 12:01 31 ************ 110 2024-07-01 13:00 31 ************ 111 2024-07-01 13:59 36 ***************** ... ..( 2 skipped). .. ***************** 114 2024-07-01 16:56 36 ***************** 115 2024-07-01 17:55 34 *************** 116 2024-07-01 18:54 ? - 117 2024-07-01 19:53 28 ********* 118 2024-07-01 20:52 28 ********* 119 2024-07-01 21:51 ? - 120 2024-07-01 22:50 25 ****** 121 2024-07-01 23:49 25 ****** 122 2024-07-02 00:48 36 ***************** ... ..( 2 skipped). .. ***************** 125 2024-07-02 03:45 36 ***************** 126 2024-07-02 04:44 35 **************** 127 2024-07-02 05:43 35 **************** 0 2024-07-02 06:42 34 *************** ... ..( 4 skipped). .. *************** 5 2024-07-02 11:37 34 *************** 6 2024-07-02 12:36 ? - 7 2024-07-02 13:35 25 ****** 8 2024-07-02 14:34 25 ****** 9 2024-07-02 15:33 35 **************** 10 2024-07-02 16:32 36 ***************** ... ..( 3 skipped). .. ***************** 14 2024-07-02 20:28 36 ***************** 15 2024-07-02 21:27 35 **************** 16 2024-07-02 22:26 34 *************** ... ..( 4 skipped). .. *************** 21 2024-07-03 03:21 34 *************** 22 2024-07-03 04:20 35 **************** 23 2024-07-03 05:19 36 ***************** 24 2024-07-03 06:18 ? - 25 2024-07-03 07:17 24 ***** 26 2024-07-03 08:16 24 ***** 27 2024-07-03 09:15 31 ************ 28 2024-07-03 10:14 32 ************* 29 2024-07-03 11:13 32 ************* 30 2024-07-03 12:12 32 ************* 31 2024-07-03 13:11 ? - 32 2024-07-03 14:10 22 *** 33 2024-07-03 15:09 22 *** 34 2024-07-03 16:08 ? - 35 2024-07-03 17:07 23 **** 36 2024-07-03 18:06 23 **** 37 2024-07-03 19:05 32 ************* 38 2024-07-03 20:04 32 ************* 39 2024-07-03 21:03 31 ************ 40 2024-07-03 22:02 31 ************ 41 2024-07-03 23:01 31 ************ 42 2024-07-04 00:00 30 *********** 43 2024-07-04 00:59 30 *********** 44 2024-07-04 01:58 ? - 45 2024-07-04 02:57 21 ** 46 2024-07-04 03:56 21 ** 47 2024-07-04 04:55 28 ********* 48 2024-07-04 05:54 28 ********* 49 2024-07-04 06:53 29 ********** 50 2024-07-04 07:52 29 ********** 51 2024-07-04 08:51 28 ********* 52 2024-07-04 09:50 ? - 53 2024-07-04 10:49 19 - 54 2024-07-04 11:48 19 - 55 2024-07-04 12:47 28 ********* 56 2024-07-04 13:46 29 ********** ... ..( 2 skipped). .. ********** 59 2024-07-04 16:43 29 ********** 60 2024-07-04 17:42 28 ********* ... ..( 2 skipped). .. ********* 63 2024-07-04 20:39 28 ********* 64 2024-07-04 21:38 27 ******** 65 2024-07-04 22:37 ? - 66 2024-07-04 23:36 19 - 67 2024-07-05 00:35 19 - 68 2024-07-05 01:34 28 ********* 69 2024-07-05 02:33 28 ********* 70 2024-07-05 03:32 29 ********** 71 2024-07-05 04:31 28 ********* 72 2024-07-05 05:30 28 ********* 73 2024-07-05 06:29 28 ********* 74 2024-07-05 07:28 27 ******** 75 2024-07-05 08:27 ? - 76 2024-07-05 09:26 18 - 77 2024-07-05 10:25 18 - 78 2024-07-05 11:24 27 ******** ... ..( 4 skipped). .. ******** 83 2024-07-05 16:19 27 ******** 84 2024-07-05 17:18 26 ******* 85 2024-07-05 18:17 26 ******* 86 2024-07-05 19:16 ? - 87 2024-07-05 20:15 17 - 88 2024-07-05 21:14 17 - 89 2024-07-05 22:13 26 ******* 90 2024-07-05 23:12 27 ******** 91 2024-07-06 00:11 27 ******** 92 2024-07-06 01:10 27 ******** 93 2024-07-06 02:09 26 ******* 94 2024-07-06 03:08 26 ******* 95 2024-07-06 04:07 25 ****** 96 2024-07-06 05:06 ? - 97 2024-07-06 06:05 18 - 98 2024-07-06 07:04 18 - 99 2024-07-06 08:03 ? - 100 2024-07-06 09:02 18 - 101 2024-07-06 10:01 18 - SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x000a 2 8 Device-to-host register FISes sent due to a COMRESET 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS /dev/sdh smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.9.7-200.fc40.x86_64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Barracuda Green (AF) Device Model: ST2000DL003-9VT166 Serial Number: -- LU WWN Device Id: 5 000c50 ... Firmware Version: CC32 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 5900 rpm Device is: In smartctl database 7.3/5528 ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 1.5 Gb/s) Local Time is: Sat Jul 6 10:20:55 2024 AEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM level is: 0 (vendor specific), recommended: 254 APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 612) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 338) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x30b7) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 111 099 006 - 37725256 3 Spin_Up_Time PO---- 092 092 000 - 0 4 Start_Stop_Count -O--CK 100 100 020 - 421 5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0 7 Seek_Error_Rate POSR-- 075 060 030 - 33591985 9 Power_On_Hours -O--CK 087 087 000 - 12241 10 Spin_Retry_Count PO--C- 100 100 097 - 0 12 Power_Cycle_Count -O--CK 100 100 020 - 414 183 Runtime_Bad_Block -O--CK 100 100 000 - 0 184 End-to-End_Error -O--CK 100 100 099 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 098 000 - 4295032845 189 High_Fly_Writes -O-RCK 099 099 000 - 1 190 Airflow_Temperature_Cel -O---K 077 059 045 - 23 (Min/Max 18/23) 191 G-Sense_Error_Rate -O--CK 100 100 000 - 0 192 Power-Off_Retract_Count -O--CK 100 100 000 - 103 193 Load_Cycle_Count -O--CK 100 100 000 - 423 194 Temperature_Celsius -O---K 023 041 000 - 23 (0 16 0 0 0) 195 Hardware_ECC_Recovered -O-RC- 032 003 000 - 37725256 197 Current_Pending_Sector -O--C- 100 100 000 - 0 198 Offline_Uncorrectable ----C- 100 100 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 36 240 Head_Flying_Hours ------ 100 253 000 - 12264 (250 57 0) 241 Total_LBAs_Written ------ 100 253 000 - 2342177887 242 Total_LBAs_Read ------ 100 253 000 - 3896297116 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 5 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 GPL,SL VS 20 Device vendor specific log 0xa2 GPL VS 2248 Device vendor specific log 0xa8 GPL,SL VS 20 Device vendor specific log 0xa9 GPL,SL VS 1 Device vendor specific log 0xab GPL VS 1 Device vendor specific log 0xb0 GPL VS 2819 Device vendor specific log 0xbd GPL VS 252 Device vendor specific log 0xbe-0xbf GPL VS 65535 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (5 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 11980 - # 2 Extended offline Completed without error 00% 11923 - # 3 Short offline Completed without error 00% 11908 - # 4 Extended offline Completed without error 00% 11006 - # 5 Extended offline Completed without error 00% 11001 - # 6 Short offline Interrupted (host reset) 00% 10985 - # 7 Extended offline Completed without error 00% 10334 - # 8 Extended offline Completed without error 00% 9591 - # 9 Extended offline Completed without error 00% 8871 - #10 Extended offline Completed without error 00% 8127 - #11 Extended offline Completed without error 00% 7383 - #12 Extended offline Completed without error 00% 6663 - #13 Extended offline Completed without error 00% 5918 - #14 Extended offline Completed without error 00% 5198 - #15 Extended offline Completed without error 00% 4453 - #16 Extended offline Completed without error 00% 3781 - #17 Extended offline Completed without error 00% 3038 - #18 Extended offline Completed without error 00% 2294 - #19 Extended offline Completed without error 00% 1574 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 522 (0x020a) Device State: Active (0) Current Temperature: 22 Celsius Power Cycle Min/Max Temperature: 18/22 Celsius Lifetime Min/Max Temperature: 16/41 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 59 minutes Min/Max recommended Temperature: 14/55 Celsius Min/Max Temperature Limit: 10/60 Celsius Temperature History Size (Index): 128 (126) Index Estimated Time Temperature Celsius 127 2024-07-01 05:08 25 ****** 0 2024-07-01 06:07 25 ****** 1 2024-07-01 07:06 ? - 2 2024-07-01 08:05 27 ******** 3 2024-07-01 09:04 27 ******** 4 2024-07-01 10:03 ? - 5 2024-07-01 11:02 31 ************ 6 2024-07-01 12:01 31 ************ 7 2024-07-01 13:00 36 ***************** 8 2024-07-01 13:59 37 ****************** 9 2024-07-01 14:58 37 ****************** 10 2024-07-01 15:57 37 ****************** 11 2024-07-01 16:56 35 **************** 12 2024-07-01 17:55 ? - 13 2024-07-01 18:54 28 ********* 14 2024-07-01 19:53 28 ********* 15 2024-07-01 20:52 37 ****************** 16 2024-07-01 21:51 ? - 17 2024-07-01 22:50 25 ****** 18 2024-07-01 23:49 25 ****** 19 2024-07-02 00:48 36 ***************** ... ..( 4 skipped). .. ***************** 24 2024-07-02 05:43 36 ***************** 25 2024-07-02 06:42 34 *************** ... ..( 4 skipped). .. *************** 30 2024-07-02 11:37 34 *************** 31 2024-07-02 12:36 ? - 32 2024-07-02 13:35 25 ****** 33 2024-07-02 14:34 25 ****** 34 2024-07-02 15:33 36 ***************** ... ..( 4 skipped). .. ***************** 39 2024-07-02 20:28 36 ***************** 40 2024-07-02 21:27 35 **************** 41 2024-07-02 22:26 35 **************** 42 2024-07-02 23:25 34 *************** ... ..( 3 skipped). .. *************** 46 2024-07-03 03:21 34 *************** 47 2024-07-03 04:20 36 ***************** 48 2024-07-03 05:19 37 ****************** 49 2024-07-03 06:18 ? - 50 2024-07-03 07:17 24 ***** 51 2024-07-03 08:16 24 ***** 52 2024-07-03 09:15 32 ************* 53 2024-07-03 10:14 33 ************** 54 2024-07-03 11:13 33 ************** 55 2024-07-03 12:12 33 ************** 56 2024-07-03 13:11 ? - 57 2024-07-03 14:10 22 *** 58 2024-07-03 15:09 22 *** 59 2024-07-03 16:08 ? - 60 2024-07-03 17:07 23 **** 61 2024-07-03 18:06 23 **** 62 2024-07-03 19:05 32 ************* 63 2024-07-03 20:04 32 ************* 64 2024-07-03 21:03 32 ************* 65 2024-07-03 22:02 31 ************ 66 2024-07-03 23:01 31 ************ 67 2024-07-04 00:00 30 *********** 68 2024-07-04 00:59 30 *********** 69 2024-07-04 01:58 ? - 70 2024-07-04 02:57 21 ** 71 2024-07-04 03:56 21 ** 72 2024-07-04 04:55 28 ********* 73 2024-07-04 05:54 28 ********* 74 2024-07-04 06:53 30 *********** 75 2024-07-04 07:52 29 ********** 76 2024-07-04 08:51 28 ********* 77 2024-07-04 09:50 ? - 78 2024-07-04 10:49 19 - 79 2024-07-04 11:48 19 - 80 2024-07-04 12:47 28 ********* 81 2024-07-04 13:46 29 ********** ... ..( 4 skipped). .. ********** 86 2024-07-04 18:41 29 ********** 87 2024-07-04 19:40 28 ********* 88 2024-07-04 20:39 28 ********* 89 2024-07-04 21:38 27 ******** 90 2024-07-04 22:37 ? - 91 2024-07-04 23:36 19 - 92 2024-07-05 00:35 19 - 93 2024-07-05 01:34 28 ********* 94 2024-07-05 02:33 28 ********* 95 2024-07-05 03:32 29 ********** 96 2024-07-05 04:31 28 ********* 97 2024-07-05 05:30 28 ********* 98 2024-07-05 06:29 28 ********* 99 2024-07-05 07:28 27 ******** 100 2024-07-05 08:27 ? - 101 2024-07-05 09:26 18 - 102 2024-07-05 10:25 18 - 103 2024-07-05 11:24 28 ********* 104 2024-07-05 12:23 28 ********* 105 2024-07-05 13:22 27 ******** ... ..( 2 skipped). .. ******** 108 2024-07-05 16:19 27 ******** 109 2024-07-05 17:18 26 ******* 110 2024-07-05 18:17 26 ******* 111 2024-07-05 19:16 ? - 112 2024-07-05 20:15 17 - 113 2024-07-05 21:14 17 - 114 2024-07-05 22:13 27 ******** ... ..( 3 skipped). .. ******** 118 2024-07-06 02:09 27 ******** 119 2024-07-06 03:08 26 ******* 120 2024-07-06 04:07 25 ****** 121 2024-07-06 05:06 ? - 122 2024-07-06 06:05 18 - 123 2024-07-06 07:04 18 - 124 2024-07-06 08:03 ? - 125 2024-07-06 09:02 18 - 126 2024-07-06 10:01 18 - SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x000a 2 8 Device-to-host register FISes sent due to a COMRESET 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS


Hardware for Linux and BSD

GitHub