Probe #48369a1b3c of Dell Latitude 3400
Log: smartctl
/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.14.2-desktop-3omv2590] (OpenMandriva Lx 7.4-1)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Patriot M.2 P300
Serial Number: --
Firmware Version: EDFMB0.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat Jun 21 18:27:23 2025 -03
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 28 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 1%
Data Units Read: 12,994,070 [6.65 TB]
Data Units Written: 10,007,908 [5.12 TB]
Host Read Commands: 1,374,550,808
Host Write Commands: 796,994,894
Controller Busy Time: 4,789
Power Cycles: 300
Power On Hours: 325
Unsafe Shutdowns: 62
Media and Data Integrity Errors: 0
Error Information Log Entries: 1,640
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 42 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 1640 0 0x6016 0x4004 - 0 0 - Invalid Field in Command
1 1639 0 0x6015 0x4004 - 0 0 - Invalid Field in Command
2 1638 0 0x6013 0x4004 0x004 0 1 - Invalid Field in Command
3 1637 0 0x100e 0x4004 0x004 0 1 - Invalid Field in Command
4 1636 0 0x0014 0x4005 0x028 0 0 - Invalid Field in Command
Read Self-test Log failed: Invalid Field in Command (0x2002)