Log: smartctl
/dev/sda
smartctl 7.3 2022-02-28 r5338 [i686-linux-6.0.0-5-686] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Fujitsu MHV
Device Model: FUJITSU MHV2120AH
Serial Number: --
Firmware Version: 000000A0
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 T13/1532D revision 4a
Local Time is: Wed Dec 14 19:29:43 2022 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 254
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 647) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 82) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 100 046 - 149939
2 Throughput_Performance P-S--- 100 100 030 - 26804682
3 Spin_Up_Time PO---- 100 100 025 - 1
4 Start_Stop_Count -O--CK 099 099 000 - 4179
5 Reallocated_Sector_Ct PO--CK 100 100 024 - 0 (2000 0)
7 Seek_Error_Rate POSR-- 100 100 047 - 2839
8 Seek_Time_Performance P-S--- 100 100 019 - 0
9 Power_On_Seconds -O--CK 066 066 000 - 17052h+47m+21s
10 Spin_Retry_Count PO--C- 100 100 020 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 4179
192 Power-Off_Retract_Count -O--CK 098 098 000 - 525
193 Load_Cycle_Count -O--CK 095 095 000 - 111990
194 Temperature_Celsius -O---K 100 100 000 - 45 (Min/Max 16/59)
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 3636
196 Reallocated_Event_Count -O--CK 100 100 000 - 0 (0 6923)
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate POSR-- 100 100 060 - 14649
203 Run_Out_Cancel -O---- 100 100 000 - 429528579112
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory not supported
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x09 SL R/W 1 Selective self-test log
0x80-0x9f SL R/W 16 Host vendor specific log
0xa1 SL VS 1 Device vendor specific log
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 12105 -
# 2 Extended offline Interrupted (host reset) 70% 12103 -
# 3 Conveyance offline Completed without error 00% 12103 -
# 4 Short offline Completed without error 00% 12103 -
# 5 Extended offline Completed without error 00% 9365 -
# 6 Short offline Completed without error 00% 9364 -
# 7 Extended offline Aborted by host 60% 9364 -
# 8 Extended offline Completed without error 00% 1653 -
# 9 Extended offline Completed without error 00% 211 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 0 (0x0000)
Device State: Active (0)
Current Temperature: 45 Celsius
Power Cycle Min/Max Temperature: --/46 Celsius
Lifetime Min/Max Temperature: --/59 Celsius
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 5/60 Celsius
Min/Max Temperature Limit: -40/65 Celsius
Temperature History Size (Index): 128 (11)
Index Estimated Time Temperature Celsius
12 2022-12-14 17:22 43 ************************
... ..( 62 skipped). .. ************************
75 2022-12-14 18:25 43 ************************
76 2022-12-14 18:26 42 ***********************
77 2022-12-14 18:27 43 ************************
... ..( 27 skipped). .. ************************
105 2022-12-14 18:55 43 ************************
106 2022-12-14 18:56 44 *************************
107 2022-12-14 18:57 43 ************************
108 2022-12-14 18:58 43 ************************
109 2022-12-14 18:59 44 *************************
... ..( 18 skipped). .. *************************
0 2022-12-14 19:18 44 *************************
1 2022-12-14 19:19 45 **************************
2 2022-12-14 19:20 45 **************************
3 2022-12-14 19:21 44 *************************
4 2022-12-14 19:22 45 **************************
5 2022-12-14 19:23 45 **************************
6 2022-12-14 19:24 45 **************************
7 2022-12-14 19:25 46 ***************************
8 2022-12-14 19:26 45 **************************
9 2022-12-14 19:27 46 ***************************
10 2022-12-14 19:28 46 ***************************
11 2022-12-14 19:29 45 **************************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported