Probe #557f08423d of Toshiba Satellite L40

Log: smartctl

/dev/sda === START OF INFORMATION SECTION === Model Family: Toshiba 2.5" HDD MK..37GSX Device Model: TOSHIBA MK1237GSX Serial Number: -- Firmware Version: DL130M User Capacity: 120 034 123 776 bytes [120 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-7 (minor revision not indicated) Local Time is: Sun Sep 4 23:58:38 2016 GMT-5 SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 25) The self-test routine was aborted by the host. Total time to complete Offline data collection: ( 120) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 80) minutes. SCT capabilities: (0x0001) SCT Status supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0 2 Throughput_Performance P-S--- 100 100 050 - 0 3 Spin_Up_Time POS--K 100 100 001 - 1644 4 Start_Stop_Count -O--CK 100 100 000 - 4971 5 Reallocated_Sector_Ct PO--CK 100 100 050 - 6 7 Seek_Error_Rate PO-R-- 100 100 050 - 0 8 Seek_Time_Performance P-S--- 100 100 050 - 0 9 Power_On_Hours -O--CK 080 080 000 - 8372 10 Spin_Retry_Count PO--CK 199 100 030 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 4928 192 Power-Off_Retract_Count -O--CK 100 100 000 - 98 193 Load_Cycle_Count -O--CK 088 088 000 - 121936 194 Temperature_Celsius -O---K 100 100 000 - 33 (Min/Max 12/55) 196 Reallocated_Event_Count -O--CK 100 100 000 - 6 197 Current_Pending_Sector -O--CK 100 100 000 - 0 198 Offline_Uncorrectable ----CK 100 100 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 220 Disk_Shift -O---- 100 100 000 - 186 222 Loaded_Hours -O--CK 082 082 000 - 7328 223 Load_Retry_Count -O--CK 100 100 000 - 0 224 Load_Friction -O---K 100 100 000 - 0 226 Load-in_Time -OS--K 100 100 000 - 230 240 Head_Flying_Hours P----- 100 100 001 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 51 Comprehensive SMART error log 0x03 GPL R/O 64 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 SATA NCQ Queued Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (64 sectors) Device Error Count: 136 CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 136 [135] occurred at disk power-on lifetime: 7039 hours (293 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 02 00 00 00 3f b0 be e0 00 Error: UNC 2 sectors at LBA = 0x003fb0be = 4174014 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 08 3f b0 b7 3f b0 b8 e0 00 00:11:16.662 READ DMA c8 00 00 00 08 3f b0 af 3f b0 b0 e0 00 00:11:16.662 READ DMA c8 00 00 00 08 3f b0 a7 3f b0 a8 e0 00 00:11:16.662 READ DMA c8 00 00 00 08 3f b0 9f 3f b0 a0 e0 00 00:11:16.662 READ DMA c8 00 00 00 08 3f b0 97 3f b0 98 e0 00 00:11:16.662 READ DMA Error 135 [134] occurred at disk power-on lifetime: 7039 hours (293 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 02 00 00 00 3f b0 be e0 00 Error: UNC 2 sectors at LBA = 0x003fb0be = 4174014 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 08 3f b0 b7 3f b0 b8 e0 00 00:11:08.973 READ DMA c8 00 00 00 08 3f b0 af 3f b0 b0 e0 00 00:11:08.973 READ DMA c8 00 00 00 08 3f b0 a7 3f b0 a8 e0 00 00:11:08.973 READ DMA c8 00 00 00 08 3f b0 9f 3f b0 a0 e0 00 00:11:08.973 READ DMA c8 00 00 00 08 3f b0 97 3f b0 98 e0 00 00:11:08.972 READ DMA Error 134 [133] occurred at disk power-on lifetime: 7039 hours (293 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 02 00 00 00 3f b0 be e0 00 Error: UNC 2 sectors at LBA = 0x003fb0be = 4174014 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 08 3f b0 b7 3f b0 b8 e0 00 00:11:01.273 READ DMA c8 00 00 00 08 3f b0 af 3f b0 b0 e0 00 00:11:01.273 READ DMA c8 00 00 00 08 3f b0 a7 3f b0 a8 e0 00 00:11:01.273 READ DMA c8 00 00 00 08 3f b0 9f 3f b0 a0 e0 00 00:11:01.272 READ DMA c8 00 00 00 08 3f b0 97 3f b0 98 e0 00 00:11:01.272 READ DMA Error 133 [132] occurred at disk power-on lifetime: 7039 hours (293 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 02 00 00 00 3f b0 be e0 00 Error: UNC 2 sectors at LBA = 0x003fb0be = 4174014 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 08 3f b0 b7 3f b0 b8 e0 00 00:10:53.528 READ DMA c8 00 00 00 08 3f b0 af 3f b0 b0 e0 00 00:10:53.528 READ DMA c8 00 00 00 08 3f b0 a7 3f b0 a8 e0 00 00:10:53.528 READ DMA c8 00 00 00 08 3f b0 9f 3f b0 a0 e0 00 00:10:53.528 READ DMA c8 00 00 00 08 3f b0 97 3f b0 98 e0 00 00:10:53.528 READ DMA Error 132 [131] occurred at disk power-on lifetime: 7039 hours (293 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 02 00 00 00 3f b0 be e0 00 Error: UNC 2 sectors at LBA = 0x003fb0be = 4174014 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 08 3f b0 b7 3f b0 b8 e0 00 00:10:45.806 READ DMA c8 00 00 00 08 3f b0 af 3f b0 b0 e0 00 00:10:45.806 READ DMA c8 00 00 00 08 3f b0 a7 3f b0 a8 e0 00 00:10:45.805 READ DMA c8 00 00 00 08 3f b0 9f 3f b0 a0 e0 00 00:10:45.805 READ DMA c8 00 00 00 08 3f b0 97 3f b0 98 e0 00 00:10:45.805 READ DMA Error 131 [130] occurred at disk power-on lifetime: 7039 hours (293 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 02 00 00 00 3f b0 be e0 00 Error: UNC 2 sectors at LBA = 0x003fb0be = 4174014 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 08 3f b0 b7 3f b0 b8 e0 00 00:10:38.106 READ DMA c8 00 00 00 08 3f b0 af 3f b0 b0 e0 00 00:10:38.105 READ DMA c8 00 00 00 08 3f b0 a7 3f b0 a8 e0 00 00:10:38.105 READ DMA c8 00 00 00 08 3f b0 9f 3f b0 a0 e0 00 00:10:38.105 READ DMA c8 00 00 00 08 3f b0 97 3f b0 98 e0 00 00:10:38.105 READ DMA Error 130 [129] occurred at disk power-on lifetime: 7039 hours (293 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 02 00 00 00 3f b0 be e0 00 Error: UNC 2 sectors at LBA = 0x003fb0be = 4174014 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 08 3f b0 b7 3f b0 b8 e0 00 00:10:25.372 READ DMA c8 00 00 00 08 3f b0 af 3f b0 b0 e0 00 00:10:25.372 READ DMA c8 00 00 00 08 3f b0 a7 3f b0 a8 e0 00 00:10:25.372 READ DMA c8 00 00 00 08 3f b0 9f 3f b0 a0 e0 00 00:10:25.371 READ DMA c8 00 00 00 08 3f b0 97 3f b0 98 e0 00 00:10:25.371 READ DMA Error 129 [128] occurred at disk power-on lifetime: 7039 hours (293 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 02 00 00 00 3f b0 be e0 00 Error: UNC 2 sectors at LBA = 0x003fb0be = 4174014 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- c8 00 00 00 08 3f b0 b7 3f b0 b8 e0 00 00:10:17.649 READ DMA c8 00 00 00 08 3f b0 af 3f b0 b0 e0 00 00:10:17.649 READ DMA c8 00 00 00 08 3f b0 a7 3f b0 a8 e0 00 00:10:17.649 READ DMA c8 00 00 00 08 3f b0 9f 3f b0 a0 e0 00 00:10:17.649 READ DMA c8 00 00 00 08 3f b0 97 3f b0 98 e0 00 00:10:17.649 READ DMA SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Aborted by host 90% 8333 - # 2 Short offline Completed without error 00% 1 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 1 (0x0001) SCT Support Level: 1 Device State: Active (0) Current Temperature: 33 Celsius Power Cycle Max Temperature: 33 Celsius Lifetime Max Temperature: 55 Celsius SCT Data Table command not supported SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0002 4 0 R_ERR response for data FIS 0x0003 4 0 R_ERR response for device-to-host data FIS 0x0004 4 0 R_ERR response for host-to-device data FIS 0x0005 4 0 R_ERR response for non-data FIS 0x0006 4 0 R_ERR response for device-to-host non-data FIS 0x0007 4 0 R_ERR response for host-to-device non-data FIS 0x0008 4 0 Device-to-host non-data FIS retries 0x0009 4 0 Transition from drive PhyRdy to drive PhyNRdy 0x000a 4 1 Device-to-host register FISes sent due to a COMRESET 0x000b 4 0 CRC errors within host-to-device FIS 0x000d 4 0 Non-CRC errors within host-to-device FIS 0x000f 4 0 R_ERR response for host-to-device data FIS, CRC 0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC


Hardware for Linux and BSD

GitHub