/dev/sda
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-5.18.12-desktop-3omv4090] (OpenMandriva Lx 7.3-2)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Scorpio Blue Serial ATA (AF)
Device Model: WDC WD3200BPVT-22ZEST0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.01A01
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Device is: In smartctl database
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Tue Jul 26 14:29:15 2022 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 128
APM level is: 96 (intermediate level with standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 7800) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 93) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x7035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 151 128 021 - 1433
4 Start_Stop_Count -O--CK 025 025 000 - 75622
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 082 082 000 - 13457
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 093 093 000 - 7568
191 G-Sense_Error_Rate -O--CK 001 001 000 - 260319
192 Power-Off_Retract_Count -O--CK 200 200 000 - 412
193 Load_Cycle_Count -O--CK 001 001 000 - 911830
194 Temperature_Celsius -O---K 101 093 000 - 42
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 140 (device log contains only the most recent 24 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 140 [19] occurred at disk power-on lifetime: 7656 hours (319 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 00 08 00 00 1f 7a 01 78 40 00 Error: IDNF at LBA = 0x1f7a0178 = 528089464
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 18 00 78 00 00 1f 58 60 00 40 08 00:28:58.332 WRITE FPDMA QUEUED
61 00 10 00 70 00 00 1f 58 74 20 40 08 00:28:58.332 WRITE FPDMA QUEUED
61 00 18 00 60 00 00 21 c1 bb 90 40 08 00:28:58.331 WRITE FPDMA QUEUED
61 00 08 00 58 00 00 20 c7 71 30 40 08 00:28:58.331 WRITE FPDMA QUEUED
61 00 18 00 68 00 00 1f 58 74 00 40 08 00:28:58.331 WRITE FPDMA QUEUED
Error 139 [18] occurred at disk power-on lifetime: 7656 hours (319 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 00 08 00 00 1f 7a 01 78 40 00 Error: IDNF at LBA = 0x1f7a0178 = 528089464
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 18 00 20 00 00 1f 58 73 98 40 08 00:28:52.633 WRITE FPDMA QUEUED
60 00 08 00 18 00 00 1f 7a 01 78 40 08 00:28:52.633 READ FPDMA QUEUED
60 00 50 00 10 00 00 20 a6 3c 78 40 08 00:28:52.632 READ FPDMA QUEUED
60 00 18 00 08 00 00 20 a6 3c 48 40 08 00:28:52.632 READ FPDMA QUEUED
60 00 08 00 00 00 00 20 bd 73 d0 40 08 00:28:52.632 READ FPDMA QUEUED
Error 138 [17] occurred at disk power-on lifetime: 7656 hours (319 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 00 08 00 00 1f 7a 01 78 40 00 Error: IDNF at LBA = 0x1f7a0178 = 528089464
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 20 00 98 00 00 1f 58 73 70 40 08 00:28:46.957 WRITE FPDMA QUEUED
61 00 18 00 20 00 00 21 c1 bb 70 40 08 00:28:46.957 WRITE FPDMA QUEUED
61 00 08 00 60 00 00 1f 58 73 60 40 08 00:28:46.956 WRITE FPDMA QUEUED
61 00 10 00 60 00 00 1f 58 73 48 40 08 00:28:46.949 WRITE FPDMA QUEUED
61 00 28 00 58 00 00 1f 58 73 18 40 08 00:28:46.949 WRITE FPDMA QUEUED
Error 137 [16] occurred at disk power-on lifetime: 7656 hours (319 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 00 08 00 00 1f 7a 01 78 40 00 Error: IDNF at LBA = 0x1f7a0178 = 528089464
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 08 00 70 00 00 1f 58 73 08 40 08 00:28:41.278 WRITE FPDMA QUEUED
60 00 08 00 68 00 00 1f 7a 01 78 40 08 00:28:41.278 READ FPDMA QUEUED
60 00 50 00 60 00 00 20 a6 3c 78 40 08 00:28:41.278 READ FPDMA QUEUED
60 00 18 00 38 00 00 20 a6 3c 48 40 08 00:28:41.278 READ FPDMA QUEUED
60 00 08 00 30 00 00 20 bd 73 d0 40 08 00:28:41.278 READ FPDMA QUEUED
Error 136 [15] occurred at disk power-on lifetime: 7656 hours (319 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 00 08 00 00 1f 7a 01 78 40 00 Error: IDNF at LBA = 0x1f7a0178 = 528089464
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 18 00 10 00 00 21 c1 bb 50 40 08 00:28:35.590 WRITE FPDMA QUEUED
61 00 10 00 58 00 00 1f 58 72 f0 40 08 00:28:35.590 WRITE FPDMA QUEUED
61 00 10 00 78 00 00 1f 58 72 d8 40 08 00:28:35.583 WRITE FPDMA QUEUED
60 00 08 00 70 00 00 1f 7a 01 78 40 08 00:28:35.583 READ FPDMA QUEUED
60 00 50 00 68 00 00 20 a6 3c 78 40 08 00:28:35.583 READ FPDMA QUEUED
Error 135 [14] occurred at disk power-on lifetime: 7656 hours (319 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 00 08 00 00 1f 7a 01 78 40 00 Error: IDNF at LBA = 0x1f7a0178 = 528089464
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 08 00 98 00 00 1f 58 72 c0 40 08 00:28:29.889 WRITE FPDMA QUEUED
60 00 08 00 90 00 00 1f 7a 01 78 40 08 00:28:29.889 READ FPDMA QUEUED
60 00 50 00 88 00 00 20 a6 3c 78 40 08 00:28:29.889 READ FPDMA QUEUED
60 00 18 00 80 00 00 20 a6 3c 48 40 08 00:28:29.889 READ FPDMA QUEUED
60 00 08 00 78 00 00 20 bd 73 d0 40 08 00:28:29.889 READ FPDMA QUEUED
Error 134 [13] occurred at disk power-on lifetime: 7656 hours (319 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 00 08 00 00 1f 7a 01 78 40 00 Error: IDNF at LBA = 0x1f7a0178 = 528089464
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 10 00 40 00 00 1f 58 72 98 40 08 00:28:24.192 WRITE FPDMA QUEUED
61 00 18 00 50 00 00 21 c1 bb 30 40 08 00:28:24.192 WRITE FPDMA QUEUED
61 00 18 00 38 00 00 1f 58 72 70 40 08 00:28:24.192 WRITE FPDMA QUEUED
61 00 20 00 48 00 00 1f 58 72 48 40 08 00:28:24.185 WRITE FPDMA QUEUED
61 00 18 00 38 00 00 1f 58 72 28 40 08 00:28:24.185 WRITE FPDMA QUEUED
Error 133 [12] occurred at disk power-on lifetime: 7656 hours (319 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 00 08 00 00 1f 7a 01 78 40 00 Error: IDNF at LBA = 0x1f7a0178 = 528089464
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 08 00 e0 00 00 1f 58 72 18 40 08 00:28:18.487 WRITE FPDMA QUEUED
60 00 08 00 d8 00 00 1f 7a 01 78 40 08 00:28:18.487 READ FPDMA QUEUED
60 00 50 00 d0 00 00 20 a6 3c 78 40 08 00:28:18.487 READ FPDMA QUEUED
60 00 18 00 c8 00 00 20 a6 3c 48 40 08 00:28:18.487 READ FPDMA QUEUED
60 00 08 00 c0 00 00 20 bd 73 d0 40 08 00:28:18.487 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 11506 -
# 2 Extended offline Completed without error 00% 10799 -
# 3 Short offline Completed without error 00% 7630 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Stand-by (1)
Current Temperature: 42 Celsius
Power Cycle Min/Max Temperature: 42/43 Celsius
Lifetime Min/Max Temperature: 41/51 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (116)
Index Estimated Time Temperature Celsius
117 2022-07-26 12:22 46 ***************************
... ..( 8 skipped). .. ***************************
126 2022-07-26 12:31 46 ***************************
127 2022-07-26 12:32 45 **************************
0 2022-07-26 12:33 44 *************************
1 2022-07-26 12:34 44 *************************
2 2022-07-26 12:35 44 *************************
3 2022-07-26 12:36 43 ************************
4 2022-07-26 12:37 43 ************************
5 2022-07-26 12:38 43 ************************
6 2022-07-26 12:39 42 ***********************
7 2022-07-26 12:40 42 ***********************
8 2022-07-26 12:41 42 ***********************
9 2022-07-26 12:42 41 **********************
... ..( 11 skipped). .. **********************
21 2022-07-26 12:54 41 **********************
22 2022-07-26 12:55 42 ***********************
23 2022-07-26 12:56 42 ***********************
24 2022-07-26 12:57 42 ***********************
25 2022-07-26 12:58 43 ************************
26 2022-07-26 12:59 42 ***********************
27 2022-07-26 13:00 43 ************************
28 2022-07-26 13:01 44 *************************
... ..( 5 skipped). .. *************************
34 2022-07-26 13:07 44 *************************
35 2022-07-26 13:08 43 ************************
... ..( 3 skipped). .. ************************
39 2022-07-26 13:12 43 ************************
40 2022-07-26 13:13 44 *************************
41 2022-07-26 13:14 44 *************************
42 2022-07-26 13:15 44 *************************
43 2022-07-26 13:16 43 ************************
... ..( 2 skipped). .. ************************
46 2022-07-26 13:19 43 ************************
47 2022-07-26 13:20 44 *************************
... ..( 9 skipped). .. *************************
57 2022-07-26 13:30 44 *************************
58 2022-07-26 13:31 43 ************************
59 2022-07-26 13:32 43 ************************
60 2022-07-26 13:33 43 ************************
61 2022-07-26 13:34 42 ***********************
62 2022-07-26 13:35 42 ***********************
63 2022-07-26 13:36 42 ***********************
64 2022-07-26 13:37 41 **********************
... ..( 28 skipped). .. **********************
93 2022-07-26 14:06 41 **********************
94 2022-07-26 14:07 42 ***********************
95 2022-07-26 14:08 42 ***********************
96 2022-07-26 14:09 43 ************************
97 2022-07-26 14:10 43 ************************
98 2022-07-26 14:11 42 ***********************
99 2022-07-26 14:12 42 ***********************
100 2022-07-26 14:13 ? -
101 2022-07-26 14:14 43 ************************
102 2022-07-26 14:15 43 ************************
103 2022-07-26 14:16 43 ************************
104 2022-07-26 14:17 ? -
105 2022-07-26 14:18 43 ************************
106 2022-07-26 14:19 ? -
107 2022-07-26 14:20 43 ************************
108 2022-07-26 14:21 43 ************************
109 2022-07-26 14:22 43 ************************
110 2022-07-26 14:23 ? -
111 2022-07-26 14:24 43 ************************
112 2022-07-26 14:25 ? -
113 2022-07-26 14:26 43 ************************
114 2022-07-26 14:27 42 ***********************
115 2022-07-26 14:28 42 ***********************
116 2022-07-26 14:29 42 ***********************
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 471 Vendor specific