/dev/nvme0n1
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.1-desktop-1omv2290] (OpenMandriva Lx 7.3-2)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: CT1000P3SSD8
Serial Number: --
Firmware Version: P9CR30A
PCI Vendor/Subsystem ID: 0xc0a9
IEEE OUI Identifier: 0x00a075
Controller ID: 1
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,000,204,886,016 [1.00 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Tue Jan 17 12:13:23 2023 -03
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x06): Cmd_Eff_Lg Ext_Get_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 6.00W 0.0000W - 0 0 0 0 0 0
1 + 3.00W 0.0000W - 0 0 0 0 0 0
2 + 1.50W 0.0000W - 0 0 0 0 0 0
3 - 0.0250W 0.0000W - 3 3 3 3 5000 1900
4 - 0.0030W - - 4 4 4 4 13000 100000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 41 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 1%
Data Units Read: 14,544,386 [7.44 TB]
Data Units Written: 13,218,054 [6.76 TB]
Host Read Commands: 145,972,939
Host Write Commands: 102,687,046
Controller Busy Time: 165
Power Cycles: 201
Power On Hours: 300
Unsafe Shutdowns: 85
Media and Data Integrity Errors: 0
Error Information Log Entries: 1,279
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 41 Celsius
Temperature Sensor 2: 46 Celsius
Temperature Sensor 8: 41 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 1279 0 0x500f 0x4005 0x028 0 0 -
/dev/sda
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.1-desktop-1omv2290] (OpenMandriva Lx 7.3-2)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Samsung SpinPoint M8U (USB)
Device Model: ST1000LM025 HN-M101ABB
Serial Number: --
LU WWN Device Id: 0 000000 ...
Firmware Version: 2AR10001
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Device is: In smartctl database
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Tue Jan 17 12:13:23 2023 -03
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unknown
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 121) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: (13080) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 218) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 1
2 Throughput_Performance -OS--K 252 252 000 - 0
3 Spin_Up_Time PO---K 086 086 025 - 4452
4 Start_Stop_Count -O--CK 064 064 000 - 37245
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
8 Seek_Time_Performance --S--K 252 252 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 5651
10 Spin_Retry_Count -O--CK 252 252 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 48
12 Power_Cycle_Count -O--CK 098 098 000 - 2714
191 G-Sense_Error_Rate -O---K 100 100 000 - 18
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
194 Temperature_Celsius -O---- 061 048 000 - 39 (Min/Max 23/55)
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 1
198 Offline_Uncorrectable ----CK 252 252 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 69
223 Load_Retry_Count -O--CK 100 100 000 - 48
225 Load_Cycle_Count -O--CK 083 083 000 - 177032
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 2 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xc0-0xdf GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (2 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed: read failure 90% 5647 1953524696
# 2 Short offline Completed: read failure 90% 5645 1953524696
# 3 Short offline Completed: read failure 90% 5644 1953524696
# 4 Short offline Completed: read failure 90% 5639 1953524696
# 5 Short offline Completed: read failure 90% 5636 1953524696
# 6 Short offline Completed: read failure 90% 5635 1953524696
# 7 Short offline Completed: read failure 90% 5634 1953524696
# 8 Short offline Completed: read failure 90% 5633 1953524696
# 9 Short offline Completed: read failure 90% 5632 1953524696
#10 Short offline Completed: read failure 90% 5630 1953524696
#11 Short offline Completed: read failure 90% 5629 1953524696
#12 Short offline Completed: read failure 90% 5628 1953524696
#13 Short offline Completed: read failure 70% 5623 1953524696
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed_read_failure [90% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 39 Celsius
Power Cycle Min/Max Temperature: 30/39 Celsius
Lifetime Min/Max Temperature: 20/55 Celsius
Specified Max Operating Temperature: 80 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 5 minutes
Temperature Logging Interval: 5 minutes
Min/Max recommended Temperature: -5/80 Celsius
Min/Max Temperature Limit: -10/85 Celsius
Temperature History Size (Index): 128 (80)
Index Estimated Time Temperature Celsius
81 2023-01-17 01:35 39 ********************
82 2023-01-17 01:40 34 ***************
83 2023-01-17 01:45 35 ****************
84 2023-01-17 01:50 36 *****************
85 2023-01-17 01:55 34 ***************
86 2023-01-17 02:00 35 ****************
87 2023-01-17 02:05 36 *****************
88 2023-01-17 02:10 35 ****************
89 2023-01-17 02:15 35 ****************
90 2023-01-17 02:20 35 ****************
91 2023-01-17 02:25 36 *****************
92 2023-01-17 02:30 37 ******************
93 2023-01-17 02:35 38 *******************
... ..( 2 skipped). .. *******************
96 2023-01-17 02:50 38 *******************
97 2023-01-17 02:55 39 ********************
98 2023-01-17 03:00 40 *********************
99 2023-01-17 03:05 40 *********************
100 2023-01-17 03:10 37 ******************
101 2023-01-17 03:15 38 *******************
102 2023-01-17 03:20 39 ********************
103 2023-01-17 03:25 39 ********************
104 2023-01-17 03:30 39 ********************
105 2023-01-17 03:35 38 *******************
106 2023-01-17 03:40 39 ********************
107 2023-01-17 03:45 39 ********************
108 2023-01-17 03:50 39 ********************
109 2023-01-17 03:55 40 *********************
110 2023-01-17 04:00 41 **********************
111 2023-01-17 04:05 40 *********************
112 2023-01-17 04:10 40 *********************
113 2023-01-17 04:15 41 **********************
114 2023-01-17 04:20 40 *********************
115 2023-01-17 04:25 41 **********************
116 2023-01-17 04:30 39 ********************
117 2023-01-17 04:35 39 ********************
118 2023-01-17 04:40 37 ******************
119 2023-01-17 04:45 37 ******************
120 2023-01-17 04:50 38 *******************
121 2023-01-17 04:55 39 ********************
122 2023-01-17 05:00 39 ********************
123 2023-01-17 05:05 39 ********************
124 2023-01-17 05:10 40 *********************
125 2023-01-17 05:15 40 *********************
126 2023-01-17 05:20 39 ********************
127 2023-01-17 05:25 40 *********************
0 2023-01-17 05:30 41 **********************
1 2023-01-17 05:35 41 **********************
2 2023-01-17 05:40 44 *************************
3 2023-01-17 05:45 45 **************************
4 2023-01-17 05:50 44 *************************
5 2023-01-17 05:55 45 **************************
6 2023-01-17 06:00 44 *************************
7 2023-01-17 06:05 43 ************************
8 2023-01-17 06:10 42 ***********************
... ..( 6 skipped). .. ***********************
15 2023-01-17 06:45 42 ***********************
16 2023-01-17 06:50 40 *********************
17 2023-01-17 06:55 41 **********************
18 2023-01-17 07:00 41 **********************
19 2023-01-17 07:05 39 ********************
20 2023-01-17 07:10 40 *********************
21 2023-01-17 07:15 41 **********************
22 2023-01-17 07:20 40 *********************
23 2023-01-17 07:25 40 *********************
24 2023-01-17 07:30 40 *********************
25 2023-01-17 07:35 37 ******************
26 2023-01-17 07:40 38 *******************
27 2023-01-17 07:45 39 ********************
28 2023-01-17 07:50 39 ********************
29 2023-01-17 07:55 42 ***********************
... ..( 2 skipped). .. ***********************
32 2023-01-17 08:10 42 ***********************
33 2023-01-17 08:15 40 *********************
34 2023-01-17 08:20 40 *********************
35 2023-01-17 08:25 41 **********************
36 2023-01-17 08:30 41 **********************
37 2023-01-17 08:35 40 *********************
38 2023-01-17 08:40 40 *********************
39 2023-01-17 08:45 41 **********************
40 2023-01-17 08:50 41 **********************
41 2023-01-17 08:55 38 *******************
42 2023-01-17 09:00 38 *******************
43 2023-01-17 09:05 39 ********************
44 2023-01-17 09:10 40 *********************
45 2023-01-17 09:15 41 **********************
46 2023-01-17 09:20 41 **********************
47 2023-01-17 09:25 41 **********************
48 2023-01-17 09:30 37 ******************
49 2023-01-17 09:35 37 ******************
50 2023-01-17 09:40 38 *******************
51 2023-01-17 09:45 38 *******************
52 2023-01-17 09:50 39 ********************
53 2023-01-17 09:55 38 *******************
... ..( 2 skipped). .. *******************
56 2023-01-17 10:10 38 *******************
57 2023-01-17 10:15 40 *********************
58 2023-01-17 10:20 40 *********************
59 2023-01-17 10:25 39 ********************
60 2023-01-17 10:30 38 *******************
61 2023-01-17 10:35 38 *******************
62 2023-01-17 10:40 38 *******************
63 2023-01-17 10:45 39 ********************
64 2023-01-17 10:50 40 *********************
65 2023-01-17 10:55 40 *********************
66 2023-01-17 11:00 39 ********************
67 2023-01-17 11:05 40 *********************
68 2023-01-17 11:10 39 ********************
69 2023-01-17 11:15 40 *********************
70 2023-01-17 11:20 41 **********************
71 2023-01-17 11:25 34 ***************
72 2023-01-17 11:30 36 *****************
73 2023-01-17 11:35 37 ******************
74 2023-01-17 11:40 38 *******************
75 2023-01-17 11:45 38 *******************
76 2023-01-17 11:50 39 ********************
77 2023-01-17 11:55 38 *******************
78 2023-01-17 12:00 37 ******************
79 2023-01-17 12:05 38 *******************
80 2023-01-17 12:10 39 ********************
SMART WRITE LOG does not return COUNT and LBA_LOW register
SCT (Get) Error Recovery Control command failed
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 4 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8e00 4 0 Vendor specific
0x8e01 4 0 Vendor specific
0x8e02 4 0 Vendor specific
0x8e03 4 0 Vendor specific
0x8e04 4 0 Vendor specific
0x8e05 4 0 Vendor specific
0x8e06 4 0 Vendor specific
0x8e07 4 0 Vendor specific
0x8e08 4 0 Vendor specific
0x8e09 4 0 Vendor specific
0x8e0a 4 0 Vendor specific
0x8e0b 4 0 Vendor specific
0x8e0c 4 0 Vendor specific
0x8e0d 4 0 Vendor specific
0x8e0e 4 0 Vendor specific
0x8e0f 4 0 Vendor specific
0x8e10 4 0 Vendor specific
0x8e11 4 0 Vendor specific
/dev/sdb
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.1-desktop-1omv2290] (OpenMandriva Lx 7.3-2)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SanDisk based SSDs
Device Model: SanDisk SSD U100 64GB
Serial Number: --
LU WWN Device Id: 5 001b40 ...
Firmware Version: KM.10.00
User Capacity: 64,023,257,088 bytes [64.0 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 1.8 inches
TRIM Command: Available, deterministic
Device is: In smartctl database
ATA Version is: ACS-2 T13/2015-D revision 3
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Tue Jan 17 12:13:24 2023 -03
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x51) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 12) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct -O---- 100 100 000 - 0
9 Power_On_Hours -O---- 100 100 000 - 12
12 Power_Cycle_Count -O---- 100 100 000 - 863
171 Program_Fail_Count -O---- 100 100 000 - 0
172 Erase_Fail_Count -O---- 100 100 000 - 0
173 Avg_Write/Erase_Count -O---- 100 100 000 - 11
174 Unexpect_Power_Loss_Ct -O---- 100 100 000 - 324
187 Reported_Uncorrect -O---- 100 100 000 - 0
230 Perc_Write/Erase_Count -O---- 100 100 000 - 36
232 Perc_Avail_Resrvd_Space PO---- 100 100 005 - 0
234 Perc_Write/Erase_Ct_BC -O---- 100 100 000 - 10
241 Total_LBAs_Written -O---- 100 100 000 - 1107488533
242 Total_LBAs_Read -O---- 100 100 000 - 732516962
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x03 GPL,SL R/O 16 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 GPL,SL R/O 1 SMART self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 1 Device vendor specific log
0xa2 GPL,SL VS 2 Device vendor specific log
0xa3 GPL,SL VS 1 Device vendor specific log
Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum.
SMART Extended Comprehensive Error Log Version: 1 (16 sectors)
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
Warning! SMART Self-Test Log Structure error: invalid SMART checksum.
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 11 -
# 2 Short offline Completed without error 00% 11 -
# 3 Short offline Completed without error 00% 11 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 37 --- Current Temperature
0x05 0x010 1 - --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 68 --- Highest Temperature
0x05 0x028 1 27 --- Lowest Temperature
0x05 0x030 1 - --- Highest Average Short Term Temperature
0x05 0x038 1 - --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 95 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 0 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 545 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 0 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0001 2 0 Command failed due to ICRC error
/dev/sdc
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.1-desktop-1omv2290] (OpenMandriva Lx 7.3-2)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: INTEL SSDPEKNW512G8
Serial Number: --
Firmware Version: 004C
PCI Vendor/Subsystem ID: 0x8086
IEEE OUI Identifier: 0x5cd2e4
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Local Time is: Tue Jan 17 12:13:24 2023 -03
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0f): S/H_per_NS Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
Maximum Data Transfer Size: 32 Pages
Warning Comp. Temp. Threshold: 77 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 3.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.00W - - 2 2 2 2 0 0
3 - 0.0250W - - 3 3 3 3 5000 5000
4 - 0.0040W - - 4 4 4 4 5000 9000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 52 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 2%
Data Units Read: 15,651,075 [8.01 TB]
Data Units Written: 14,538,830 [7.44 TB]
Host Read Commands: 239,521,049
Host Write Commands: 332,584,588
Controller Busy Time: 3,915
Power Cycles: 27,477
Power On Hours: 1,172
Unsafe Shutdowns: 158
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Thermal Temp. 1 Transition Count: 457
Thermal Temp. 1 Total Time: 2876
Warning: NVMe Get Log truncated to 0x200 bytes, 0x200 bytes zero filled
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged