/dev/sda
smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.40-generic-1rosa-x86_64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.10
Device Model: ST3250820A
Serial Number: --
Firmware Version: 3.AAF
User Capacity: 250,059,316,736 bytes [250 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Mon May 26 11:02:30 2025 +04
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 92) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 119 087 006 - 210847050
3 Spin_Up_Time PO---- 095 095 000 - 0
4 Start_Stop_Count -O--CK 097 097 020 - 3214
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 050 040 030 - 5441826481437
9 Power_On_Hours -O--CK 094 094 000 - 5339
10 Spin_Retry_Count PO--C- 100 099 097 - 0
12 Power_Cycle_Count -O--CK 098 098 020 - 3041
187 Reported_Uncorrect -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 058 043 045 Past 42 (Min/Max 29/42)
194 Temperature_Celsius -O---K 042 057 000 - 42 (0 10 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 068 052 000 - 224729421
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23552 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 26 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 26 [5] occurred at disk power-on lifetime: 5043 hours (210 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 01 01 00 00 00 00 00 00 a0 00
Error: ICRC, ABRT 257 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 20 00 01 00 00 00 00 00 00 a0 00 00:00:08.254 READ DMA
ef 00 03 00 45 00 00 3f 00 00 00 a0 00 00:00:07.707 SET FEATURES [Set transfer mode]
ef 00 03 00 0c 00 00 3f 00 00 00 a0 00 00:00:07.685 SET FEATURES [Set transfer mode]
c6 00 da 00 10 00 02 17 00 fd 10 a0 00 00:00:07.127 SET MULTIPLE MODE
b0 00 da 01 00 00 02 17 00 fd 10 a0 00 09:10:38.209 SMART RETURN STATUS
Error 25 [4] occurred at disk power-on lifetime: 2852 hours (118 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 00 00 00 00 00 00 00 e0 00
Error: ICRC, ABRT at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:00:13.093 READ DMA EXT
b0 00 da 01 00 00 00 4f 00 c2 00 e0 00 00:00:12.882 SMART RETURN STATUS
b0 00 d2 01 00 00 00 4f 00 c2 00 e0 00 00:00:12.462 SMART ENABLE/DISABLE ATTRIBUTE AUTOSAVE
b0 00 d8 01 00 00 00 4f 00 c2 00 e0 00 00:00:07.076 SMART ENABLE OPERATIONS
91 00 00 00 3f 00 0f 00 00 00 00 ef 00 09:10:38.209 INITIALIZE DEVICE PARAMETERS [OBS-6]
Error 24 [3] occurred at disk power-on lifetime: 5043 hours (210 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 00 00 00 00 00 00 00 e0 00
Error: ICRC, ABRT at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 20 00 01 00 00 00 00 00 00 e0 00 00:00:11.762 READ DMA EXT
c6 00 20 00 10 00 0f 00 00 00 01 ef 00 00:00:11.762 SET MULTIPLE MODE
91 00 20 00 3f 00 0f 00 00 00 01 ef 00 00:00:11.755 INITIALIZE DEVICE PARAMETERS [OBS-6]
10 00 20 00 01 00 01 00 00 00 01 e1 00 00:00:11.076 RECALIBRATE [OBS-4]
00 00 00 00 01 00 00 00 00 00 00 00 00 00:00:08.730 NOP [Abort queued commands]
Error 23 [2] occurred at disk power-on lifetime: 5043 hours (210 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 00 00 00 00 00 00 00 e0 00
Error: ICRC, ABRT at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 20 00 01 00 00 00 00 00 00 e0 00 00:00:11.762 READ DMA EXT
c6 00 20 00 10 00 0f 00 00 00 01 ef 00 00:00:11.762 SET MULTIPLE MODE
91 00 20 00 3f 00 0f 00 00 00 01 ef 00 00:00:11.755 INITIALIZE DEVICE PARAMETERS [OBS-6]
10 00 20 00 01 00 01 00 00 00 01 e1 00 00:00:11.076 RECALIBRATE [OBS-4]
00 00 00 01 00 00 00 00 00 00 01 00 00 00:00:08.730 NOP [Abort queued commands]
Error 22 [1] occurred at disk power-on lifetime: 5043 hours (210 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 01 01 00 00 00 00 00 00 a0 00
Error: ICRC, ABRT 257 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 20 00 01 00 00 00 00 00 00 a0 00 00:00:08.254 READ DMA
ef 00 03 00 45 00 00 3f 00 00 00 a0 00 00:00:07.707 SET FEATURES [Set transfer mode]
ef 00 03 00 0c 00 00 3f 00 00 00 a0 00 00:00:07.685 SET FEATURES [Set transfer mode]
c6 00 da 00 10 00 02 17 00 fd 10 a0 00 00:00:07.127 SET MULTIPLE MODE
b0 00 da 01 00 00 02 17 00 fd 10 a0 00 09:10:38.209 SMART RETURN STATUS
Error 21 [0] occurred at disk power-on lifetime: 2852 hours (118 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 00 00 00 00 00 00 00 e0 00
Error: ICRC, ABRT at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 00 00 00 00 e0 00 00:00:13.093 READ DMA EXT
b0 00 da 01 00 00 00 4f 00 c2 00 e0 00 00:00:12.882 SMART RETURN STATUS
b0 00 d2 01 00 00 00 4f 00 c2 00 e0 00 00:00:12.462 SMART ENABLE/DISABLE ATTRIBUTE AUTOSAVE
b0 00 d8 01 00 00 00 4f 00 c2 00 e0 00 00:00:07.076 SMART ENABLE OPERATIONS
91 00 00 00 3f 00 0f 00 00 00 00 ef 00 09:10:38.209 INITIALIZE DEVICE PARAMETERS [OBS-6]
Error 20 [19] occurred at disk power-on lifetime: 5043 hours (210 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 00 00 00 00 00 00 00 e0 00
Error: ICRC, ABRT at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 20 00 01 00 00 00 00 00 00 e0 00 00:00:11.762 READ DMA EXT
c6 00 20 00 10 00 0f 00 00 00 01 ef 00 00:00:11.762 SET MULTIPLE MODE
91 00 20 00 3f 00 0f 00 00 00 01 ef 00 00:00:11.755 INITIALIZE DEVICE PARAMETERS [OBS-6]
10 00 20 00 01 00 01 00 00 00 01 e1 00 00:00:11.076 RECALIBRATE [OBS-4]
00 00 00 00 01 00 00 00 00 00 00 00 00 00:00:08.730 NOP [Abort queued commands]
Error 19 [18] occurred at disk power-on lifetime: 5043 hours (210 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 00 00 00 00 00 00 00 e0 00
Error: ICRC, ABRT at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 20 00 01 00 00 00 00 00 00 e0 00 00:00:11.762 READ DMA EXT
c6 00 20 00 10 00 0f 00 00 00 01 ef 00 00:00:11.762 SET MULTIPLE MODE
91 00 20 00 3f 00 0f 00 00 00 01 ef 00 00:00:11.755 INITIALIZE DEVICE PARAMETERS [OBS-6]
10 00 20 00 01 00 01 00 00 00 01 e1 00 00:00:11.076 RECALIBRATE [OBS-4]
00 00 00 01 00 00 00 00 00 00 01 00 00 00:00:08.730 NOP [Abort queued commands]
SMART Extended Self-test Log Version: 1 (1 sectors)
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported