/dev/sda
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.10
Device Model: ST3250310AS
Serial Number: --
Firmware Version: 3.AAC
User Capacity: 250,059,350,016 bytes [250 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Fri Mar 23 21:53:06 2018 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 64) minutes.
SCT capabilities: (0x0001) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 117 089 006 - 0
3 Spin_Up_Time PO---- 097 097 000 - 0
4 Start_Stop_Count -O--CK 092 092 020 - 8377
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 3
7 Seek_Error_Rate POSR-- 089 060 030 - 813125334
9 Power_On_Hours -O--CK 077 077 000 - 20269
10 Spin_Retry_Count PO--C- 100 099 097 - 0
12 Power_Cycle_Count -O--CK 094 094 020 - 6853
187 Reported_Uncorrect -O--CK 001 001 000 - 7886
189 High_Fly_Writes -O-RCK 098 098 000 - 2
190 Airflow_Temperature_Cel -O---K 062 042 045 Past 38 (Min/Max 28/41)
194 Temperature_Celsius -O---K 038 058 000 - 38 (0 18 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 070 053 000 - 33831120
197 Current_Pending_Sector -O--C- 100 098 000 - 0
198 Offline_Uncorrectable ----C- 100 098 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 199 000 - 49
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 098 251 000 - 2
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 SATA NCQ Queued Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23040 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 8095 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 8095 [14] occurred at disk power-on lifetime: 19413 hours (808 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 ff 00 5f 07 40 00
Error: UNC at LBA = 0xff005f07 = 4278214407
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 ff 01 00 00 00 ff 00 5f 00 40 00 01:46:42.839 READ DMA EXT
25 00 ff 01 00 00 02 3b 00 3b 00 40 00 01:46:42.838 READ DMA EXT
25 00 ff 01 00 00 00 fe 00 5f 00 40 00 01:46:42.837 READ DMA EXT
25 00 ff 01 00 00 00 fd 00 5f 00 40 00 01:46:42.826 READ DMA EXT
25 00 ff 01 00 00 00 fc 00 5f 00 40 00 01:46:42.825 READ DMA EXT
Error 8094 [13] occurred at disk power-on lifetime: 19412 hours (808 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 93 00 01 8d 40 00
Error: UNC at LBA = 0x9300018d = 2466251149
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 ff 00 3d 00 00 93 00 01 74 40 00 00:24:30.132 READ DMA EXT
25 00 ff 00 02 00 00 93 00 01 72 40 00 00:24:30.178 READ DMA EXT
25 00 ff 00 02 00 00 93 00 01 70 40 00 00:24:30.178 READ DMA EXT
25 00 ff 00 08 00 00 c5 00 5b 38 40 00 00:24:30.174 READ DMA EXT
25 00 ff 00 08 00 00 10 00 60 40 40 00 00:24:30.174 READ DMA EXT
Error 8093 [12] occurred at disk power-on lifetime: 19410 hours (808 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 93 00 01 8d 40 00
Error: UNC at LBA = 0x9300018d = 2466251149
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 ff 00 3d 00 00 93 00 01 74 40 00 00:03:33.621 READ DMA EXT
25 00 ff 00 02 00 00 93 00 01 72 40 00 00:03:33.614 READ DMA EXT
25 00 ff 00 02 00 00 93 00 01 70 40 00 00:03:33.613 READ DMA EXT
25 00 ff 00 08 00 00 10 00 60 40 40 00 00:03:33.600 READ DMA EXT
25 00 ff 00 08 00 00 c5 00 5b 38 40 00 00:03:33.599 READ DMA EXT
Error 8092 [11] occurred at disk power-on lifetime: 19414 hours (808 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 93 00 01 8d 40 00
Error: UNC at LBA = 0x9300018d = 2466251149
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 ff 00 3d 00 00 93 00 01 74 40 00 00:01:17.304 READ DMA EXT
25 00 ff 00 02 00 00 93 00 01 72 40 00 00:01:17.304 READ DMA EXT
25 00 ff 00 02 00 00 93 00 01 70 40 00 00:01:17.298 READ DMA EXT
25 00 ff 00 08 00 00 c5 00 5b 38 40 00 00:01:17.295 READ DMA EXT
25 00 ff 00 08 00 00 10 00 60 40 40 00 00:01:17.288 READ DMA EXT
Error 8091 [10] occurred at disk power-on lifetime: 19413 hours (808 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 ff 00 5f 07 40 00
Error: UNC at LBA = 0xff005f07 = 4278214407
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 ff 01 00 00 00 ff 00 5f 00 40 00 01:46:42.839 READ DMA EXT
25 00 ff 01 00 00 02 3b 00 3b 00 40 00 01:46:42.838 READ DMA EXT
25 00 ff 01 00 00 00 fe 00 5f 00 40 00 01:46:42.837 READ DMA EXT
25 00 ff 01 00 00 00 fd 00 5f 00 40 00 01:46:42.826 READ DMA EXT
25 00 ff 01 00 00 00 fc 00 5f 00 40 00 01:46:42.825 READ DMA EXT
Error 8090 [9] occurred at disk power-on lifetime: 19412 hours (808 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 93 00 01 8d 40 00
Error: UNC at LBA = 0x9300018d = 2466251149
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 ff 00 3d 00 00 93 00 01 74 40 00 00:24:30.132 READ DMA EXT
25 00 ff 00 02 00 00 93 00 01 72 40 00 00:24:30.178 READ DMA EXT
25 00 ff 00 02 00 00 93 00 01 70 40 00 00:24:30.178 READ DMA EXT
25 00 ff 00 08 00 00 c5 00 5b 38 40 00 00:24:30.174 READ DMA EXT
25 00 ff 00 08 00 00 10 00 60 40 40 00 00:24:30.174 READ DMA EXT
Error 8089 [8] occurred at disk power-on lifetime: 19410 hours (808 days + 18 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 93 00 01 8d 40 00
Error: UNC at LBA = 0x9300018d = 2466251149
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 ff 00 3d 00 00 93 00 01 74 40 00 00:03:33.621 READ DMA EXT
25 00 ff 00 02 00 00 93 00 01 72 40 00 00:03:33.614 READ DMA EXT
25 00 ff 00 02 00 00 93 00 01 70 40 00 00:03:33.613 READ DMA EXT
25 00 ff 00 08 00 00 10 00 60 40 40 00 00:03:33.600 READ DMA EXT
25 00 ff 00 08 00 00 c5 00 5b 38 40 00 00:03:33.599 READ DMA EXT
Error 8088 [7] occurred at disk power-on lifetime: 19414 hours (808 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 93 00 01 8d 40 00
Error: UNC at LBA = 0x9300018d = 2466251149
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 ff 00 3d 00 00 93 00 01 74 40 00 00:01:17.304 READ DMA EXT
25 00 ff 00 02 00 00 93 00 01 72 40 00 00:01:17.304 READ DMA EXT
25 00 ff 00 02 00 00 93 00 01 70 40 00 00:01:17.298 READ DMA EXT
25 00 ff 00 08 00 00 c5 00 5b 38 40 00 00:01:17.295 READ DMA EXT
25 00 ff 00 08 00 00 10 00 60 40 40 00 00:01:17.288 READ DMA EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 521 (0x0209)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 38 Celsius
Power Cycle Max Temperature: 0 Celsius
Lifetime Max Temperature: 0 Celsius
SCT Data Table command not supported
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 22 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0009 2 21 Transition from drive PhyRdy to drive PhyNRdy
0x8002 2 0 Vendor specific
0x8003 2 8 Vendor specific
0x8004 2 0 Vendor specific