/dev/sda
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.15.4-arch2-1] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar Blue Serial ATA
Device Model: WDC WD3200AAJS-00L7A0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.03E01
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.5/5706
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Mon Jul 7 04:19:32 2025 +07
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 128
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 6000) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 73) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 325
3 Spin_Up_Time POS--K 141 124 021 - 3908
4 Start_Stop_Count -O--CK 091 091 000 - 9502
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
9 Power_On_Hours -O--CK 031 031 000 - 50517
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 091 091 000 - 9105
192 Power-Off_Retract_Count -O--CK 196 196 000 - 3689
193 Load_Cycle_Count -O--CK 197 197 000 - 9504
194 Temperature_Celsius -O---K 103 091 000 - 40
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 17
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 3012 (device log contains only the most recent 24 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 3012 [11] occurred at disk power-on lifetime: 28668 hours (1194 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 c0 00 95 c8 e0 00
Error: UNC 1 sectors at LBA = 0xc00095c8 = 3221263816
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 00 95 c0 c8 e0 00 04:48:44.587 READ DMA EXT
25 00 00 00 01 00 00 00 95 c0 c7 e0 00 04:48:44.587 READ DMA EXT
35 00 00 00 08 00 00 00 61 5d 80 e0 00 04:48:44.587 WRITE DMA EXT
25 00 00 00 01 00 00 00 95 c0 c6 e0 00 04:48:44.587 READ DMA EXT
25 00 00 00 08 00 00 08 6a 8e 48 e0 00 04:48:44.574 READ DMA EXT
Error 3011 [10] occurred at disk power-on lifetime: 28668 hours (1194 days + 12 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 20 00 00 c0 00 95 c0 e0 00
Error: UNC 32 sectors at LBA = 0xc00095c0 = 3221263808
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 20 00 00 00 95 c0 c0 e0 00 04:48:41.947 READ DMA EXT
35 00 00 00 10 00 00 0b 9e fc 00 e0 00 04:48:41.947 WRITE DMA EXT
25 00 00 00 10 00 00 00 95 c8 c0 e0 00 04:48:41.947 READ DMA EXT
25 00 00 00 40 00 00 01 35 8a c0 e0 00 04:48:41.947 READ DMA EXT
35 00 00 00 20 00 00 0b 9e fb e0 e0 00 04:48:41.946 WRITE DMA EXT
Error 3010 [9] occurred at disk power-on lifetime: 28552 hours (1189 days + 16 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 c0 00 95 c8 e0 00
Error: UNC 1 sectors at LBA = 0xc00095c8 = 3221263816
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 00 95 c0 c8 e0 00 01:39:09.734 READ DMA EXT
25 00 00 00 01 00 00 00 95 c0 c7 e0 00 01:39:09.734 READ DMA EXT
25 00 00 00 01 00 00 00 95 c0 c6 e0 00 01:39:09.734 READ DMA EXT
25 00 00 00 01 00 00 00 95 c0 c5 e0 00 01:39:09.733 READ DMA EXT
25 00 00 00 01 00 00 00 95 c0 c4 e0 00 01:39:09.733 READ DMA EXT
Error 3009 [8] occurred at disk power-on lifetime: 28552 hours (1189 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 20 00 00 c0 00 95 c0 e0 00
Error: UNC 32 sectors at LBA = 0xc00095c0 = 3221263808
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 20 00 00 00 95 c0 c0 e0 00 01:39:07.439 READ DMA EXT
35 00 00 00 08 00 00 00 b9 1f 90 e0 00 01:39:07.439 WRITE DMA EXT
35 00 00 00 08 00 00 00 b9 1f 80 e0 00 01:39:07.438 WRITE DMA EXT
35 00 00 00 20 00 00 08 76 35 e0 e0 00 01:39:07.438 WRITE DMA EXT
35 00 00 00 20 00 00 08 7b c9 80 e0 00 01:39:07.437 WRITE DMA EXT
Error 3008 [7] occurred at disk power-on lifetime: 28544 hours (1189 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 c0 00 95 c8 e0 00
Error: UNC 1 sectors at LBA = 0xc00095c8 = 3221263816
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 00 95 c0 c8 e0 00 03:35:51.508 READ DMA EXT
25 00 00 00 01 00 00 00 95 c0 c7 e0 00 03:35:51.508 READ DMA EXT
25 00 00 00 01 00 00 00 95 c0 c6 e0 00 03:35:51.508 READ DMA EXT
25 00 00 00 01 00 00 00 95 c0 c5 e0 00 03:35:51.508 READ DMA EXT
25 00 00 00 01 00 00 00 95 c0 c4 e0 00 03:35:51.508 READ DMA EXT
Error 3007 [6] occurred at disk power-on lifetime: 28544 hours (1189 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 20 00 00 c0 00 95 c0 e0 00
Error: UNC 32 sectors at LBA = 0xc00095c0 = 3221263808
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 20 00 00 00 95 c0 c0 e0 00 03:35:48.871 READ DMA EXT
35 00 00 00 08 00 00 01 df d9 50 e0 00 03:35:48.871 WRITE DMA EXT
35 00 00 00 20 00 00 07 08 3d 20 e0 00 03:35:48.871 WRITE DMA EXT
35 00 00 00 20 00 00 06 fc 26 00 e0 00 03:35:48.871 WRITE DMA EXT
25 00 00 00 20 00 00 01 df d9 40 e0 00 03:35:48.864 READ DMA EXT
Error 3006 [5] occurred at disk power-on lifetime: 28533 hours (1188 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 01 00 00 c0 00 95 c8 e0 00
Error: UNC 1 sectors at LBA = 0xc00095c8 = 3221263816
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 01 00 00 00 95 c0 c8 e0 00 06:47:46.689 READ DMA EXT
25 00 00 00 01 00 00 00 95 c0 c7 e0 00 06:47:46.689 READ DMA EXT
25 00 00 00 01 00 00 00 95 c0 c6 e0 00 06:47:46.689 READ DMA EXT
25 00 00 00 01 00 00 00 95 c0 c5 e0 00 06:47:46.689 READ DMA EXT
25 00 00 00 01 00 00 00 95 c0 c4 e0 00 06:47:46.689 READ DMA EXT
Error 3005 [4] occurred at disk power-on lifetime: 28533 hours (1188 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 20 00 00 c0 00 95 c0 e0 00
Error: UNC 32 sectors at LBA = 0xc00095c0 = 3221263808
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 00 20 00 00 00 95 c0 c0 e0 00 06:47:44.458 READ DMA EXT
35 00 00 00 08 00 00 01 5e 8f d0 e0 00 06:47:44.457 WRITE DMA EXT
25 00 00 00 08 00 00 00 67 56 38 e0 00 06:47:44.457 READ DMA EXT
25 00 00 00 20 00 00 00 22 9c 0d e0 00 06:47:44.446 READ DMA EXT
25 00 00 00 08 00 00 01 df fe d8 e0 00 06:47:44.445 READ DMA EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 40 Celsius
Power Cycle Min/Max Temperature: 38/44 Celsius
Lifetime Min/Max Temperature: 39/52 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (154)
Index Estimated Time Temperature Celsius
155 2025-07-06 20:22 42 ***********************
... ..( 25 skipped). .. ***********************
181 2025-07-06 20:48 42 ***********************
182 2025-07-06 20:49 41 **********************
... ..( 39 skipped). .. **********************
222 2025-07-06 21:29 41 **********************
223 2025-07-06 21:30 42 ***********************
224 2025-07-06 21:31 41 **********************
... ..( 7 skipped). .. **********************
232 2025-07-06 21:39 41 **********************
233 2025-07-06 21:40 42 ***********************
... ..( 32 skipped). .. ***********************
266 2025-07-06 22:13 42 ***********************
267 2025-07-06 22:14 41 **********************
... ..( 57 skipped). .. **********************
325 2025-07-06 23:12 41 **********************
326 2025-07-06 23:13 40 *********************
... ..( 20 skipped). .. *********************
347 2025-07-06 23:34 40 *********************
348 2025-07-06 23:35 39 ********************
... ..(142 skipped). .. ********************
13 2025-07-07 01:58 39 ********************
14 2025-07-07 01:59 40 *********************
... ..( 50 skipped). .. *********************
65 2025-07-07 02:50 40 *********************
66 2025-07-07 02:51 42 ***********************
... ..( 87 skipped). .. ***********************
154 2025-07-07 04:19 42 ***********************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 22 Device-to-host register FISes sent due to a COMRESET
0x8000 4 435345 Vendor specific
/dev/sdb
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.15.4-arch2-1] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.14 (AF)
Device Model: ST250DM000-1BD141
Serial Number: --
LU WWN Device Id: 5 000c50 ...
Firmware Version: KC48
User Capacity: 250,059,350,016 bytes [250 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Device is: In smartctl database 7.5/5706
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Jul 7 04:19:32 2025 +07
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 208 (intermediate), recommended: 208
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 600) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 41) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 118 097 006 - 196624192
3 Spin_Up_Time PO---- 100 098 000 - 0
4 Start_Stop_Count -O--CK 096 096 020 - 5062
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 072 060 030 - 17924027
9 Power_On_Hours -O--CK 044 044 000 - 49783
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 096 096 020 - 5001
183 Runtime_Bad_Block -O--CK 093 093 000 - 7
184 End-to-End_Error -O--CK 100 100 099 - 0
187 Reported_Uncorrect -O--CK 001 001 000 - 304
188 Command_Timeout -O--CK 100 095 000 - 15 20 181
189 High_Fly_Writes -O-RCK 093 093 000 - 7
190 Airflow_Temperature_Cel -O---K 062 048 045 - 38 (Min/Max 37/43)
194 Temperature_Celsius -O---K 038 052 000 - 38 (0 10 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 061 025 000 - 196624192
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 41
240 Head_Flying_Hours ------ 100 253 000 - 49793h+38m+17.622s
241 Total_LBAs_Written ------ 100 253 000 - 4023097591
242 Total_LBAs_Read ------ 100 253 000 - 540269330
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL VS 2248 Device vendor specific log
0xa8 GPL,SL VS 129 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xab GPL VS 1 Device vendor specific log
0xb0 GPL VS 2928 Device vendor specific log
0xbd GPL VS 252 Device vendor specific log
0xbe-0xbf GPL VS 65535 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 395 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 395 [14] occurred at disk power-on lifetime: 25672 hours (1069 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 0c 39 4a 40 00 00
Error: UNC at LBA = 0x0c394a40 = 205081152
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 f0 00 00 0c 39 4a 20 ec 00 00:09:48.842 READ DMA
35 00 00 04 00 00 00 15 38 7d 00 e0 00 00:09:48.699 WRITE DMA EXT
35 00 00 04 00 00 00 15 38 79 00 e0 00 00:09:48.697 WRITE DMA EXT
35 00 00 04 00 00 00 15 38 75 00 e0 00 00:09:48.694 WRITE DMA EXT
35 00 00 04 00 00 00 15 38 71 00 e0 00 00:09:48.691 WRITE DMA EXT
Error 394 [13] occurred at disk power-on lifetime: 25672 hours (1069 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 0c 39 4a 40 00 00
Error: UNC at LBA = 0x0c394a40 = 205081152
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 0c 39 4a 40 ec 00 00:09:42.400 READ DMA
c8 00 00 00 08 00 00 0c 39 4a 38 ec 00 00:09:42.398 READ DMA
c8 00 00 00 08 00 00 0c 39 4a 30 ec 00 00:09:42.398 READ DMA
c8 00 00 00 08 00 00 0c 39 4a 28 ec 00 00:09:42.387 READ DMA
25 00 00 02 00 00 00 0f d4 05 b0 e0 00 00:09:42.362 READ DMA EXT
Error 393 [12] occurred at disk power-on lifetime: 25672 hours (1069 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 0c 39 4a 40 00 00
Error: UNC at LBA = 0x0c394a40 = 205081152
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 02 00 00 00 0c 39 4a 20 e0 00 00:09:00.556 READ DMA EXT
25 00 00 02 00 00 00 0c 39 48 20 e0 00 00:09:00.369 READ DMA EXT
25 00 00 02 00 00 00 0c 39 46 20 e0 00 00:09:00.357 READ DMA EXT
25 00 00 02 00 00 00 0c 39 44 20 e0 00 00:09:00.256 READ DMA EXT
25 00 00 02 00 00 00 0c 39 42 20 e0 00 00:09:00.204 READ DMA EXT
Error 392 [11] occurred at disk power-on lifetime: 25671 hours (1069 days + 15 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 0c 39 4a 40 00 00
Error: UNC at LBA = 0x0c394a40 = 205081152
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 00 00 00 0c 39 49 f8 ec 00 00:19:35.594 READ DMA
25 00 00 02 00 00 00 0c e8 a2 38 e0 00 00:19:35.592 READ DMA EXT
25 00 00 00 20 00 00 18 fe 64 10 e0 00 00:19:35.592 READ DMA EXT
25 00 00 00 08 00 00 19 82 ea 90 e0 00 00:19:35.581 READ DMA EXT
25 00 00 00 68 00 00 18 fe 62 70 e0 00 00:19:35.580 READ DMA EXT
Error 391 [10] occurred at disk power-on lifetime: 25665 hours (1069 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 1c fd 58 20 00 00
Error: UNC at LBA = 0x1cfd5820 = 486365216
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 1c fd 58 00 e0 00 03:02:59.671 READ DMA EXT
25 00 00 00 08 00 00 03 41 44 70 e0 00 03:02:59.670 READ DMA EXT
25 00 00 00 20 00 00 02 84 9d 99 e0 00 03:02:59.670 READ DMA EXT
25 00 00 00 08 00 00 00 64 f1 c0 e0 00 03:02:59.669 READ DMA EXT
35 00 00 00 08 00 00 00 5f 0f a8 e0 00 03:02:59.669 WRITE DMA EXT
Error 390 [9] occurred at disk power-on lifetime: 25665 hours (1069 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 1c fd 58 20 00 00
Error: UNC at LBA = 0x1cfd5820 = 486365216
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 1c fd 58 00 e0 00 03:02:55.723 READ DMA EXT
25 00 00 00 08 00 00 03 44 76 60 e0 00 03:02:55.712 READ DMA EXT
25 00 00 00 08 00 00 03 41 44 c8 e0 00 03:02:55.712 READ DMA EXT
25 00 00 00 30 00 00 03 3c c9 50 e0 00 03:02:55.700 READ DMA EXT
25 00 00 00 40 00 00 02 ac 6f 90 e0 00 03:02:55.663 READ DMA EXT
Error 389 [8] occurred at disk power-on lifetime: 25665 hours (1069 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 1c fd 58 20 00 00
Error: UNC at LBA = 0x1cfd5820 = 486365216
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 1c fd 58 00 e0 00 03:02:51.731 READ DMA EXT
25 00 00 00 48 00 00 03 52 7d 40 e0 00 03:02:51.720 READ DMA EXT
25 00 00 00 08 00 00 03 41 4e a0 e0 00 03:02:51.710 READ DMA EXT
25 00 00 00 08 00 00 03 3d 19 c0 e0 00 03:02:51.698 READ DMA EXT
25 00 00 00 05 00 00 02 c4 9e 9a e0 00 03:02:51.697 READ DMA EXT
Error 388 [7] occurred at disk power-on lifetime: 25665 hours (1069 days + 9 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 1c fd 58 20 00 00
Error: UNC at LBA = 0x1cfd5820 = 486365216
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 00 01 00 00 00 1c fd 58 00 e0 00 03:02:47.414 READ DMA EXT
25 00 00 00 80 00 00 03 6a 93 48 e0 00 03:02:47.366 READ DMA EXT
25 00 00 00 70 00 00 03 52 0d f0 e0 00 03:02:47.348 READ DMA EXT
25 00 00 00 08 00 00 03 41 46 d0 e0 00 03:02:47.347 READ DMA EXT
25 00 00 00 38 00 00 03 3b 77 20 e0 00 03:02:47.340 READ DMA EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Aborted by host 60% 49533 -
# 2 Short offline Completed without error 00% 49533 -
# 3 Short offline Completed without error 00% 49533 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
Device State: Active (0)
Current Temperature: 38 Celsius
Power Cycle Min/Max Temperature: 37/43 Celsius
Lifetime Min/Max Temperature: 10/53 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 59 minutes
Min/Max recommended Temperature: 14/55 Celsius
Min/Max Temperature Limit: 10/60 Celsius
Temperature History Size (Index): 128 (44)
Index Estimated Time Temperature Celsius
45 2025-07-01 23:18 38 *******************
46 2025-07-02 00:17 ? -
47 2025-07-02 01:16 38 *******************
48 2025-07-02 02:15 ? -
49 2025-07-02 03:14 38 *******************
50 2025-07-02 04:13 39 ********************
51 2025-07-02 05:12 39 ********************
52 2025-07-02 06:11 38 *******************
53 2025-07-02 07:10 38 *******************
54 2025-07-02 08:09 37 ******************
55 2025-07-02 09:08 39 ********************
56 2025-07-02 10:07 38 *******************
57 2025-07-02 11:06 39 ********************
... ..( 4 skipped). .. ********************
62 2025-07-02 16:01 39 ********************
63 2025-07-02 17:00 38 *******************
64 2025-07-02 17:59 39 ********************
... ..( 2 skipped). .. ********************
67 2025-07-02 20:56 39 ********************
68 2025-07-02 21:55 40 *********************
69 2025-07-02 22:54 38 *******************
70 2025-07-02 23:53 38 *******************
71 2025-07-03 00:52 40 *********************
72 2025-07-03 01:51 40 *********************
73 2025-07-03 02:50 38 *******************
74 2025-07-03 03:49 38 *******************
75 2025-07-03 04:48 38 *******************
76 2025-07-03 05:47 37 ******************
77 2025-07-03 06:46 38 *******************
78 2025-07-03 07:45 38 *******************
79 2025-07-03 08:44 39 ********************
... ..( 6 skipped). .. ********************
86 2025-07-03 15:37 39 ********************
87 2025-07-03 16:36 40 *********************
88 2025-07-03 17:35 40 *********************
89 2025-07-03 18:34 40 *********************
90 2025-07-03 19:33 41 **********************
91 2025-07-03 20:32 41 **********************
92 2025-07-03 21:31 40 *********************
93 2025-07-03 22:30 39 ********************
94 2025-07-03 23:29 40 *********************
95 2025-07-04 00:28 41 **********************
96 2025-07-04 01:27 40 *********************
97 2025-07-04 02:26 40 *********************
98 2025-07-04 03:25 40 *********************
99 2025-07-04 04:24 39 ********************
100 2025-07-04 05:23 38 *******************
101 2025-07-04 06:22 39 ********************
102 2025-07-04 07:21 41 **********************
103 2025-07-04 08:20 41 **********************
104 2025-07-04 09:19 41 **********************
105 2025-07-04 10:18 43 ************************
106 2025-07-04 11:17 40 *********************
... ..( 3 skipped). .. *********************
110 2025-07-04 15:13 40 *********************
111 2025-07-04 16:12 41 **********************
112 2025-07-04 17:11 41 **********************
113 2025-07-04 18:10 41 **********************
114 2025-07-04 19:09 40 *********************
115 2025-07-04 20:08 41 **********************
116 2025-07-04 21:07 40 *********************
117 2025-07-04 22:06 41 **********************
... ..( 3 skipped). .. **********************
121 2025-07-05 02:02 41 **********************
122 2025-07-05 03:01 39 ********************
123 2025-07-05 04:00 39 ********************
124 2025-07-05 04:59 39 ********************
125 2025-07-05 05:58 40 *********************
126 2025-07-05 06:57 41 **********************
127 2025-07-05 07:56 41 **********************
0 2025-07-05 08:55 41 **********************
1 2025-07-05 09:54 42 ***********************
2 2025-07-05 10:53 41 **********************
3 2025-07-05 11:52 42 ***********************
4 2025-07-05 12:51 43 ************************
5 2025-07-05 13:50 42 ***********************
6 2025-07-05 14:49 43 ************************
7 2025-07-05 15:48 43 ************************
8 2025-07-05 16:47 43 ************************
9 2025-07-05 17:46 42 ***********************
10 2025-07-05 18:45 43 ************************
... ..( 4 skipped). .. ************************
15 2025-07-05 23:40 43 ************************
16 2025-07-06 00:39 42 ***********************
17 2025-07-06 01:38 43 ************************
18 2025-07-06 02:37 42 ***********************
19 2025-07-06 03:36 42 ***********************
20 2025-07-06 04:35 41 **********************
21 2025-07-06 05:34 39 ********************
22 2025-07-06 06:33 41 **********************
23 2025-07-06 07:32 40 *********************
... ..( 3 skipped). .. *********************
27 2025-07-06 11:28 40 *********************
28 2025-07-06 12:27 39 ********************
29 2025-07-06 13:26 39 ********************
30 2025-07-06 14:25 39 ********************
31 2025-07-06 15:24 40 *********************
32 2025-07-06 16:23 39 ********************
33 2025-07-06 17:22 39 ********************
34 2025-07-06 18:21 39 ********************
35 2025-07-06 19:20 40 *********************
36 2025-07-06 20:19 41 **********************
37 2025-07-06 21:18 41 **********************
38 2025-07-06 22:17 39 ********************
39 2025-07-06 23:16 40 *********************
40 2025-07-07 00:15 39 ********************
41 2025-07-07 01:14 38 *******************
... ..( 2 skipped). .. *******************
44 2025-07-07 04:11 38 *******************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 79 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS