/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.4.11-desktop-1omv2390] (OpenMandriva Lx 7.4-1)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: SAMSUNG MZVLB512HAJQ-000L2
Serial Number: --
Firmware Version: 4L1QEXA7
PCI Vendor/Subsystem ID: 0x144d
IEEE OUI Identifier: 0x002538
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 4
NVMe Version: 1.2
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Utilization: 152,931,176,448 [152 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 002538 ...
Local Time is: Wed Aug 30 10:32:22 2023 PDT
Firmware Updates (0x16): 3 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 81 Celsius
Critical Comp. Temp. Threshold: 82 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.02W - - 0 0 0 0 0 0
1 + 6.30W - - 1 1 1 1 0 0
2 + 3.50W - - 2 2 2 2 0 0
3 - 0.0760W - - 3 3 3 3 210 1200
4 - 0.0050W - - 4 4 4 4 2000 8000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 42 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 3%
Data Units Read: 38,069,011 [19.4 TB]
Data Units Written: 59,493,523 [30.4 TB]
Host Read Commands: 456,111,026
Host Write Commands: 866,773,370
Controller Busy Time: 2,944
Power Cycles: 55,911
Power On Hours: 5,292
Unsafe Shutdowns: 794
Media and Data Integrity Errors: 0
Error Information Log Entries: 12,569
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 42 Celsius
Temperature Sensor 2: 54 Celsius
Error Information (NVMe Log 0x01, 16 of 64 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 12569 0 0x601a 0x4004 - 0 1 - Invalid Field in Command
1 12568 0 0x6018 0x4004 - 0 1 - Invalid Field in Command
2 12567 0 0x501a 0x4004 - 0 1 - Invalid Field in Command
3 12566 0 0x5018 0x4004 - 0 1 - Invalid Field in Command
4 12565 0 0x401a 0x4004 - 0 1 - Invalid Field in Command
5 12564 0 0x4018 0x4004 - 0 1 - Invalid Field in Command
6 12563 0 0x301a 0x4004 - 0 1 - Invalid Field in Command
7 12562 0 0x3018 0x4004 - 0 1 - Invalid Field in Command
8 12561 0 0x201a 0x4004 - 0 1 - Invalid Field in Command
9 12560 0 0x2018 0x4004 - 0 1 - Invalid Field in Command
10 12559 0 0x101a 0x4004 - 0 1 - Invalid Field in Command
11 12558 0 0x1018 0x4004 - 0 1 - Invalid Field in Command
12 12557 0 0x001a 0x4004 - 0 1 - Invalid Field in Command
13 12556 0 0xf019 0x4004 - 0 1 - Invalid Field in Command
14 12555 0 0xe01b 0x4004 - 0 1 - Invalid Field in Command
15 12554 0 0xe019 0x4004 - 0 1 - Invalid Field in Command
... (48 entries not read)
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged
/dev/sda
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.4.11-desktop-1omv2390] (OpenMandriva Lx 7.4-1)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Blue Mobile (SMR)
Device Model: WDC WD10SPZX-24Z10
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 04.01A04
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
TRIM Command: Available, deterministic
Device is: In smartctl database
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Aug 30 10:32:22 2023 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 96 (intermediate level with standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 7680) seconds.
Offline data collection
capabilities: (0x71) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 124) minutes.
Conveyance self-test routine
recommended polling time: ( 4) minutes.
SCT capabilities: (0x303d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 194 186 021 - 1258
4 Start_Stop_Count -O--CK 001 001 000 - 203729
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 084 084 000 - 12307
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 045 045 000 - 55910
187 Reported_Uncorrect -O--CK 100 100 000 - 0
192 Power-Off_Retract_Count -O--CK 198 198 000 - 1596
193 Load_Cycle_Count -O--CK 098 098 000 - 308443
194 Temperature_Celsius -O---K 108 091 000 - 35 (Min/Max 12/52)
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
206 Flying_Height -O---K 100 000 000 - 36
240 Head_Flying_Hours -O--CK 086 086 000 - 10743
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x24 GPL R/O 288 Current Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
0xb7 GPL,SL VS 74 Device vendor specific log
0xb9 GPL,SL VS 4 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0x50) Completed without error 00% 10346 -
# 2 Short offline Completed without error 00% 10346 -
# 3 Vendor (0x50) Completed without error 00% 9836 -
# 4 Short offline Completed without error 00% 9835 -
# 5 Extended offline Interrupted (host reset) 70% 9409 -
# 6 Extended offline Interrupted (host reset) 80% 8839 -
# 7 Vendor (0x50) Completed without error 00% 8465 -
# 8 Short offline Completed without error 00% 8465 -
# 9 Short offline Aborted by host 10% 8336 -
#10 Extended offline Interrupted (host reset) 90% 7968 -
#11 Short offline Completed without error 00% 7555 -
#12 Vendor (0x50) Completed without error 00% 6596 -
#13 Short offline Completed without error 00% 6596 -
#14 Vendor (0x50) Completed without error 00% 5297 -
#15 Short offline Completed without error 00% 5297 -
#16 Vendor (0x50) Completed without error 00% 2094 -
#17 Short offline Completed without error 00% 2094 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 28/39 Celsius
Lifetime Min/Max Temperature: 12/52 Celsius
Specified Max Operating Temperature: 36 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (2)
Index Estimated Time Temperature Celsius
3 2023-08-30 08:25 28 *********
... ..( 46 skipped). .. *********
50 2023-08-30 09:12 28 *********
51 2023-08-30 09:13 ? -
52 2023-08-30 09:14 28 *********
53 2023-08-30 09:15 28 *********
54 2023-08-30 09:16 29 **********
55 2023-08-30 09:17 29 **********
56 2023-08-30 09:18 29 **********
57 2023-08-30 09:19 30 ***********
58 2023-08-30 09:20 30 ***********
59 2023-08-30 09:21 30 ***********
60 2023-08-30 09:22 31 ************
... ..( 2 skipped). .. ************
63 2023-08-30 09:25 31 ************
64 2023-08-30 09:26 32 *************
65 2023-08-30 09:27 32 *************
66 2023-08-30 09:28 ? -
67 2023-08-30 09:29 32 *************
68 2023-08-30 09:30 32 *************
69 2023-08-30 09:31 33 **************
... ..( 2 skipped). .. **************
72 2023-08-30 09:34 33 **************
73 2023-08-30 09:35 ? -
74 2023-08-30 09:36 33 **************
75 2023-08-30 09:37 ? -
76 2023-08-30 09:38 33 **************
77 2023-08-30 09:39 34 ***************
... ..( 4 skipped). .. ***************
82 2023-08-30 09:44 34 ***************
83 2023-08-30 09:45 33 **************
84 2023-08-30 09:46 33 **************
85 2023-08-30 09:47 33 **************
86 2023-08-30 09:48 34 ***************
87 2023-08-30 09:49 34 ***************
88 2023-08-30 09:50 ? -
89 2023-08-30 09:51 34 ***************
90 2023-08-30 09:52 34 ***************
91 2023-08-30 09:53 ? -
92 2023-08-30 09:54 34 ***************
93 2023-08-30 09:55 ? -
94 2023-08-30 09:56 34 ***************
95 2023-08-30 09:57 34 ***************
96 2023-08-30 09:58 34 ***************
97 2023-08-30 09:59 35 ****************
98 2023-08-30 10:00 36 *****************
99 2023-08-30 10:01 37 ******************
100 2023-08-30 10:02 38 *******************
101 2023-08-30 10:03 38 *******************
102 2023-08-30 10:04 39 ********************
103 2023-08-30 10:05 38 *******************
104 2023-08-30 10:06 38 *******************
105 2023-08-30 10:07 37 ******************
106 2023-08-30 10:08 37 ******************
107 2023-08-30 10:09 36 *****************
... ..( 2 skipped). .. *****************
110 2023-08-30 10:12 36 *****************
111 2023-08-30 10:13 35 ****************
112 2023-08-30 10:14 35 ****************
113 2023-08-30 10:15 35 ****************
114 2023-08-30 10:16 34 ***************
... ..( 4 skipped). .. ***************
119 2023-08-30 10:21 34 ***************
120 2023-08-30 10:22 ? -
121 2023-08-30 10:23 34 ***************
... ..( 4 skipped). .. ***************
126 2023-08-30 10:28 34 ***************
127 2023-08-30 10:29 35 ****************
0 2023-08-30 10:30 35 ****************
1 2023-08-30 10:31 ? -
2 2023-08-30 10:32 35 ****************
SCT Error Recovery Control:
Read: 150 (15.0 seconds)
Write: 150 (15.0 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 22 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 24 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 44503 Vendor specific