Probe #a3139f8204 of Gigabyte X58A-UD3R Desktop Computer

Log: smartctl

/dev/sda smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.10.0-desktop-1omv2490] (OpenMandriva Lx 7.4-1) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Intel 53x and Pro 1500/2500 Series SSDs Device Model: INTEL SSDSC2BW240A4 Serial Number: -- LU WWN Device Id: 5 5cd2e4 ... Firmware Version: DC32 User Capacity: 240,057,409,536 bytes [240 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device TRIM Command: Available, deterministic Device is: In smartctl database ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Tue Jan 14 18:38:17 2025 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 254 (maximum performance) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x05) Offline data collection activity was aborted by an interrupting command from host. Auto Offline Data Collection: Disabled. Self-test execution status: ( 33) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: ( 5860) seconds. Offline data collection capabilities: (0x7f) SMART execute Offline immediate. Auto Offline data collection on/off support. Abort Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 48) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x0025) SCT Status supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct -O--CK 100 100 000 - 2 9 Power_On_Hours_and_Msec -O--CK 100 100 000 - 22426h+13m+51.160s 12 Power_Cycle_Count -O--CK 099 099 000 - 1033 170 Available_Reservd_Space PO--CK 100 100 010 - 0 171 Program_Fail_Count -O--CK 100 100 000 - 1 172 Erase_Fail_Count -O--CK 100 100 000 - 0 174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 200 183 SATA_Downshift_Count -O--CK 100 100 000 - 39 184 End-to-End_Error PO--CK 100 100 090 - 0 187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0 190 Airflow_Temperature_Cel -O--CK 027 042 000 - 27 (Min/Max 11/42) 192 Power-Off_Retract_Count -O--CK 100 100 000 - 200 199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0 225 Host_Writes_32MiB -O--CK 100 100 000 - 273710 226 Workld_Media_Wear_Indic -O--CK 100 100 000 - 65535 227 Workld_Host_Reads_Perc -O--CK 100 100 000 - 88 228 Workload_Minutes -O--CK 100 100 000 - 65535 232 Available_Reservd_Space PO--CK 100 100 010 - 0 233 Media_Wearout_Indicator -O--CK 095 095 000 - 0 241 Host_Writes_32MiB -O--CK 100 100 000 - 273710 242 Host_Reads_32MiB -O--CK 100 100 000 - 2168479 249 NAND_Writes_1GiB -O--CK 100 100 000 - 42769 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x04 GPL,SL R/O 1 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL,SL R/O 1 SATA Phy Event Counters log 0x30 GPL,SL R/O 16 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xb7 GPL,SL VS 16 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log not supported SMART Extended Self-test Log Version: 0 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Offline Interrupted (host reset) 10% 22426 - # 2 Offline Interrupted (host reset) 10% 22426 - # 3 Offline Interrupted (host reset) 10% 22422 - # 4 Offline Interrupted (host reset) 10% 22420 - # 5 Offline Interrupted (host reset) 10% 22420 - # 6 Offline Interrupted (host reset) 10% 22420 - # 7 Offline Interrupted (host reset) 10% 22420 - # 8 Offline Interrupted (host reset) 10% 22420 - # 9 Offline Interrupted (host reset) 10% 22420 - #10 Offline Interrupted (host reset) 10% 22420 - #11 Offline Interrupted (host reset) 10% 22420 - #12 Offline Interrupted (host reset) 10% 22420 - #13 Offline Interrupted (host reset) 10% 22420 - #14 Offline Interrupted (host reset) 10% 22420 - #15 Offline Interrupted (host reset) 10% 22419 - #16 Offline Interrupted (host reset) 10% 22419 - #17 Offline Interrupted (host reset) 10% 22418 - #18 Offline Interrupted (host reset) 10% 22418 - #19 Offline Interrupted (host reset) 10% 22418 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 0 (0x0000) Device State: Active (0) Current Temperature: 27 Celsius Power Cycle Min/Max Temperature: 11/42 Celsius Lifetime Min/Max Temperature: 11/75 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 0 (Unknown, should be 2) Temperature Sampling Period: 1 minute Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: 0/ 0 Celsius Min/Max Temperature Limit: 0/ 0 Celsius Temperature History Size (Index): 0 (203) Temperature History is empty SCT Error Recovery Control command not supported Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 2) == 0x01 0x008 4 1044 --- Lifetime Power-On Resets 0x01 0x010 4 22437 --- Power-on Hours 0x01 0x018 6 19394266476 --- Logical Sectors Written 0x01 0x028 6 143943950112 --- Logical Sectors Read 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 8829 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 27 --- Current Temperature 0x05 0x010 1 30 --- Average Short Term Temperature 0x05 0x018 1 - --- Average Long Term Temperature 0x05 0x020 1 42 --- Highest Temperature 0x05 0x028 1 23 --- Lowest Temperature 0x05 0x030 1 38 --- Highest Average Short Term Temperature 0x05 0x038 1 30 --- Lowest Average Short Term Temperature 0x05 0x040 1 - --- Highest Average Long Term Temperature 0x05 0x048 1 - --- Lowest Average Long Term Temperature 0x05 0x050 4 0 --- Time in Over-Temperature 0x05 0x058 1 70 --- Specified Maximum Operating Temperature 0x05 0x060 4 0 --- Time in Under-Temperature 0x05 0x068 1 0 --- Specified Minimum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 8829 --- Number of Hardware Resets 0x06 0x010 4 1257 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors 0x07 ===== = = === == Solid State Device Statistics (rev 1) == 0x07 0x008 1 7 --- Percentage Used Endurance Indicator |||_ C monitored condition met ||__ D supports DSN |___ N normalized value Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 6 Device-to-host register FISes sent due to a COMRESET 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC 0x0002 2 0 R_ERR response for data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS /dev/sdb smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.10.0-desktop-1omv2490] (OpenMandriva Lx 7.4-1) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: SanDisk based SSDs Device Model: SanDisk pSSD Serial Number: -- LU WWN Device Id: 5 001b44 ... Firmware Version: 6EB 1030 User Capacity: 128,043,712,512 bytes [128 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 1.8 inches TRIM Command: Available, deterministic Device is: In smartctl database ATA Version is: ACS-2 T13/2015-D revision 3 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Tue Jan 14 18:38:17 2025 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Disabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: FAILED! Drive failure expected in less than 24 hours. SAVE ALL DATA. See vendor-specific Attribute list for failed Attributes. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 120) seconds. Offline data collection capabilities: (0x51) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 41) minutes. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct -O---- 100 100 000 - 4 9 Power_On_Hours -O---- 100 100 000 - 0 12 Power_Cycle_Count -O---- 100 100 000 - 0 165 Total_Write/Erase_Count -O---- 100 100 000 - 3221911988 171 Program_Fail_Count -O---- 100 100 000 - 0 172 Erase_Fail_Count -O---- 100 100 000 - 0 173 Avg_Write/Erase_Count -O---- 100 100 000 - 17 174 Unexpect_Power_Loss_Ct -O---- 100 100 000 - 0 187 Reported_Uncorrect -O---- 100 100 000 - 0 194 Temperature_Celsius -O---K 092 008 000 - 8 (Min/Max 0/33) 230 Perc_Write/Erase_Count -O---- 100 100 000 - 56 232 Perc_Avail_Resrvd_Space PO---- 000 100 005 NOW 0 234 Perc_Write/Erase_Ct_BC -O---- 100 100 000 - 10000 241 Total_LBAs_Written -O---- 100 100 000 - 0 242 Total_LBAs_Read -O---- 100 100 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 0 SMART Log Directory Version 0 Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log not supported SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test Log not supported SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Commands not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 0 Device-to-host register FISes sent due to a COMRESET 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0001 2 0 Command failed due to ICRC error /dev/sg1 smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.10.0-desktop-1omv2490] (OpenMandriva Lx 7.4-1) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Vendor: Marvell Product: 91xx Config Revision: 1.01 Compliance: SPC-3 User Capacity: 12,295,801,049,484,194,422 bytes [12295 PB] Logical block size: 1298231926 bytes Physical block size: 388456448 bytes Lowest aligned LBA: 11296 Formatted with type 3 protection 64 protection information intervals per logical block 512 bytes of protection information per logical block Device type: processor Local Time is: Tue Jan 14 18:38:17 2025 CET SMART support is: Unavailable - device lacks SMART capability. === START OF READ SMART DATA SECTION === Current Drive Temperature: 0 C Drive Trip Temperature: 0 C Error Counter logging not supported Device does not support Self Test logging Device does not support General statistics and performance logging


Hardware for Linux and BSD

GitHub