/dev/sda
smartctl 7.2 2021-01-17 r5171 [x86_64-linux-5.11.19-300.fc34.x86_64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: Samsung SSD 840 EVO 120GB
Serial Number: --
LU WWN Device Id: 5 002538 ...
Firmware Version: EXT0DB6Q
User Capacity: 120,034,123,776 bytes [120 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sat May 15 01:33:40 2021 AEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Unexpected SCT status 0x0001 (action_code=4, function_code=2)
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 4200) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 70) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 098 098 000 - 9384
12 Power_Cycle_Count -O--CK 099 099 000 - 993
177 Wear_Leveling_Count PO--C- 093 093 000 - 79
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 001 010 Past 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 064 045 000 - 36
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
199 CRC_Error_Count -OSRCK 099 099 000 - 2
235 POR_Recovery_Count -O--C- 099 099 000 - 141
241 Total_LBAs_Written -O--CK 099 099 000 - 18561819682
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 GPL,SL VS 16 Device vendor specific log
0xce GPL,SL VS 16 Device vendor specific log
0xde SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 1 -
# 2 Extended offline Completed without error 00% 3 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: ?/ ? Celsius
Lifetime Min/Max Temperature: ?/ ? Celsius
Under/Over Temperature Limit Count: 0/56195
SCT Temperature History Version: 2
Temperature Sampling Period: 10 minutes
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: ?/ ? Celsius
Min/Max Temperature Limit: ?/ ? Celsius
Temperature History Size (Index): 128 (20)
Index Estimated Time Temperature Celsius
21 2021-05-14 04:20 ? -
... ..(106 skipped). .. -
0 2021-05-14 22:10 ? -
1 2021-05-14 22:20 35 ****************
2 2021-05-14 22:30 35 ****************
3 2021-05-14 22:40 34 ***************
4 2021-05-14 22:50 33 **************
5 2021-05-14 23:00 33 **************
6 2021-05-14 23:10 34 ***************
7 2021-05-14 23:20 34 ***************
8 2021-05-14 23:30 33 **************
9 2021-05-14 23:40 33 **************
10 2021-05-14 23:50 32 *************
11 2021-05-15 00:00 32 *************
12 2021-05-15 00:10 32 *************
13 2021-05-15 00:20 34 ***************
14 2021-05-15 00:30 35 ****************
15 2021-05-15 00:40 35 ****************
16 2021-05-15 00:50 35 ****************
17 2021-05-15 01:00 36 *****************
... ..( 2 skipped). .. *****************
20 2021-05-15 01:30 36 *****************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 31 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 31 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
/dev/sdb
smartctl 7.2 2021-01-17 r5171 [x86_64-linux-5.11.19-300.fc34.x86_64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint M5
Device Model: SAMSUNG HM160HI
Serial Number: --
LU WWN Device Id: 5 0f0000 ...
Firmware Version: HR100-08
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 0
SATA Version is: SATA 2.5, 1.5 Gb/s
Local Time is: Sat May 15 01:33:40 2021 AEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 32) The self-test routine was interrupted
by the host with a hard or soft reset.
Total time to complete Offline
data collection: ( 64) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 64) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 2
3 Spin_Up_Time POS--- 252 252 025 - 1750
4 Start_Stop_Count -O--CK 098 098 000 - 2876
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
7 Seek_Error_Rate -OSR-- 252 252 051 - 309002240
8 Seek_Time_Performance --S--K 252 252 015 - 0
9 Power_On_Hours -O--CK 001 001 000 - 10827746
10 Spin_Retry_Count -O--CK 252 252 051 - 0
12 Power_Cycle_Count -O--CK 252 100 000 - 1382
191 G-Sense_Error_Rate -O--CK 100 100 000 - 674
192 Power-Off_Retract_Count -O--CK 100 100 000 - 237
194 Temperature_Celsius -O---K 130 085 000 - 36 (Min/Max 14/51)
195 Hardware_ECC_Recovered -O-RC- 100 001 000 - 15363
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
197 Current_Pending_Sector -O--C- 252 089 000 - 103
198 Offline_Uncorrectable ----CK 252 252 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 256
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
201 Soft_Read_Error_Rate -O--CK 252 252 000 - 0
223 Load_Retry_Count -O--CK 002 002 000 - 99999
225 Load_Cycle_Count -O--CK 002 002 000 - 999999
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x08 SL R/O 1 Power Conditions log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80 GPL,SL R/W 16 Host vendor specific log
0x81-0x9f SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Device Error Count: 55608 (device log contains only the most recent 8 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
ATA_READ_LOG_EXT (addr=0x03:0x00, page=1, n=1) failed: scsi error badly formed scsi parameters
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 11120 -
# 2 Short offline Completed without error 00% 11119 -
# 3 Extended offline Completed without error 00% 11100 -
# 4 Extended offline Aborted by host 150% 11095 -
# 5 Extended offline Aborted by host 150% 10612 -
# 6 Extended offline Completed without error 00% 10545 -
# 7 Extended offline Completed without error 00% 2131 -
# 8 Extended offline Completed without error 00% 869 -
# 9 Offline Completed without error 00% 65387 -
#10 Extended offline Completed without error 00% 65386 -
#11 Offline Interrupted (host reset) 00% 65385 -
#12 Offline Interrupted (host reset) 00% 65385 -
#13 Offline Interrupted (host reset) 00% 65385 -
#14 Offline Interrupted (host reset) 00% 65385 -
#15 Offline Interrupted (host reset) 00% 18193 -
#16 Extended offline Completed without error 00% 24176 -
#17 Extended offline Completed without error 00% 14521 -
#18 Extended offline Completed without error 00% 14199 -
#19 Extended offline Completed without error 00% 14110 -
#20 Extended offline Completed: read failure 00% 14108 42563333
#21 Vendor (0x4d) Completed: electrical failure 110% 16832 811498809
2 of 2 failed self-tests are outdated by newer successful extended offline self-test # 1
SMART Selective self-test log data structure revision number 4884
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 524310939 Interrupted [00% left] (0-65535)
2 1103106923 17792 Not_testing
3 17792 3305177088 Not_testing
4 1098973184 34017 Not_testing
5 526909440 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 33/40 Celsius
Lifetime Min/Max Temperature: 14/51 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 15/55 Celsius
Min/Max Temperature Limit: 10/60 Celsius
Temperature History Size (Index): 128 (95)
Index Estimated Time Temperature Celsius
96 2021-05-14 23:26 34 ***************
... ..( 22 skipped). .. ***************
119 2021-05-14 23:49 34 ***************
120 2021-05-14 23:50 33 **************
121 2021-05-14 23:51 33 **************
122 2021-05-14 23:52 34 ***************
123 2021-05-14 23:53 33 **************
124 2021-05-14 23:54 33 **************
125 2021-05-14 23:55 33 **************
126 2021-05-14 23:56 34 ***************
127 2021-05-14 23:57 33 **************
... ..( 7 skipped). .. **************
7 2021-05-15 00:05 33 **************
8 2021-05-15 00:06 34 ***************
9 2021-05-15 00:07 33 **************
10 2021-05-15 00:08 34 ***************
... ..( 9 skipped). .. ***************
20 2021-05-15 00:18 34 ***************
21 2021-05-15 00:19 35 ****************
... ..( 7 skipped). .. ****************
29 2021-05-15 00:27 35 ****************
30 2021-05-15 00:28 37 ******************
... ..( 5 skipped). .. ******************
36 2021-05-15 00:34 37 ******************
37 2021-05-15 00:35 36 *****************
... ..( 13 skipped). .. *****************
51 2021-05-15 00:49 36 *****************
52 2021-05-15 00:50 37 ******************
... ..( 2 skipped). .. ******************
55 2021-05-15 00:53 37 ******************
56 2021-05-15 00:54 36 *****************
... ..( 4 skipped). .. *****************
61 2021-05-15 00:59 36 *****************
62 2021-05-15 01:00 37 ******************
... ..( 20 skipped). .. ******************
83 2021-05-15 01:21 37 ******************
84 2021-05-15 01:22 36 *****************
85 2021-05-15 01:23 37 ******************
86 2021-05-15 01:24 36 *****************
87 2021-05-15 01:25 36 *****************
88 2021-05-15 01:26 37 ******************
... ..( 3 skipped). .. ******************
92 2021-05-15 01:30 37 ******************
93 2021-05-15 01:31 36 *****************
94 2021-05-15 01:32 36 *****************
95 2021-05-15 01:33 36 *****************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 26 Device-to-host register FISes sent due to a COMRESET
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x8001 2 0 Vendor specific