Probe #b89c577552 of Lenovo B50-70 20384

Log: smartctl

/dev/sda === START OF INFORMATION SECTION === Model Family: Seagate Samsung SpinPoint M8 (AF) Device Model: ST1000LM024 HN-M101MBB Serial Number: -- LU WWN Device Id: 5 0004cf ... Firmware Version: 2BA30001 User Capacity: 1 000 204 886 016 bytes [1,00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Aug 27 03:43:24 2018 +05 SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x80) Offline data collection activity was never started. Auto Offline Data Collection: Enabled. Self-test execution status: ( 39) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: (12660) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 211) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 100 100 051 - 26 2 Throughput_Performance -OS--K 055 055 000 - 11611 3 Spin_Up_Time PO---K 093 086 025 - 2422 4 Start_Stop_Count -O--CK 099 099 000 - 1046 5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0 7 Seek_Error_Rate -OSR-K 252 252 051 - 0 8 Seek_Time_Performance --S--K 252 252 015 - 0 9 Power_On_Hours -O--CK 100 100 000 - 11379 10 Spin_Retry_Count -O--CK 252 252 051 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 911 12 Power_Cycle_Count -O--CK 099 099 000 - 1048 191 G-Sense_Error_Rate -O---K 100 100 000 - 4914 192 Power-Off_Retract_Count -O---K 100 100 000 - 38 194 Temperature_Celsius -O---- 058 050 000 - 42 (Min/Max 14/50) 195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0 196 Reallocated_Event_Count -O--CK 252 252 000 - 0 197 Current_Pending_Sector -O--CK 252 252 000 - 0 198 Offline_Uncorrectable ----CK 252 252 000 - 0 199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0 200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 49451 223 Load_Retry_Count -O--CK 100 100 000 - 911 225 Load_Cycle_Count -O--CK 068 068 000 - 323337 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 2 Comprehensive SMART error log 0x03 GPL R/O 2 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 2 Extended self-test log 0x08 GPL R/O 2 Power Conditions log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 SATA NCQ Queued Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xc0-0xdf GPL,SL VS 16 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (2 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (2 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Interrupted (host reset) 70% 11319 - # 2 Extended offline Interrupted (host reset) 50% 11308 - # 3 Extended offline Completed without error 00% 11197 - # 4 Extended offline Completed without error 00% 11139 - # 5 Extended offline Completed without error 00% 11031 - # 6 Extended offline Completed without error 00% 10943 - # 7 Extended offline Completed without error 00% 10857 - # 8 Extended offline Interrupted (host reset) 90% 10772 - # 9 Extended offline Completed without error 00% 10619 - #10 Extended offline Completed without error 00% 10455 - #11 Extended offline Completed without error 00% 10310 - #12 Vendor (0x50) Completed without error 00% 10068 - #13 Short offline Completed without error 00% 10068 - #14 Vendor (0x50) Completed without error 00% 9966 - #15 Short offline Completed without error 00% 9966 - #16 Vendor (0x50) Completed without error 00% 9869 - #17 Short offline Completed without error 00% 9869 - #18 Vendor (0x50) Completed without error 00% 9648 - #19 Short offline Completed without error 00% 9647 - #20 Vendor (0x50) Completed without error 00% 9535 - #21 Short offline Completed without error 00% 9535 - SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Interrupted [70% left] (0-65535) 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 256 (0x0100) SCT Support Level: 1 Device State: Active (0) Current Temperature: 42 Celsius Power Cycle Min/Max Temperature: 24/45 Celsius Lifetime Min/Max Temperature: 14/50 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 5 minutes Temperature Logging Interval: 5 minutes Min/Max recommended Temperature: -5/80 Celsius Min/Max Temperature Limit: -10/85 Celsius Temperature History Size (Index): 128 (48) Index Estimated Time Temperature Celsius 49 2018-08-26 17:05 42 *********************** 50 2018-08-26 17:10 40 ********************* 51 2018-08-26 17:15 40 ********************* 52 2018-08-26 17:20 40 ********************* 53 2018-08-26 17:25 41 ********************** ... ..( 8 skipped). .. ********************** 62 2018-08-26 18:10 41 ********************** 63 2018-08-26 18:15 42 *********************** 64 2018-08-26 18:20 42 *********************** 65 2018-08-26 18:25 42 *********************** 66 2018-08-26 18:30 41 ********************** 67 2018-08-26 18:35 40 ********************* ... ..( 4 skipped). .. ********************* 72 2018-08-26 19:00 40 ********************* 73 2018-08-26 19:05 41 ********************** ... ..( 3 skipped). .. ********************** 77 2018-08-26 19:25 41 ********************** 78 2018-08-26 19:30 42 *********************** ... ..( 12 skipped). .. *********************** 91 2018-08-26 20:35 42 *********************** 92 2018-08-26 20:40 28 ********* 93 2018-08-26 20:45 32 ************* 94 2018-08-26 20:50 34 *************** 95 2018-08-26 20:55 35 **************** 96 2018-08-26 21:00 35 **************** 97 2018-08-26 21:05 34 *************** ... ..( 2 skipped). .. *************** 100 2018-08-26 21:20 34 *************** 101 2018-08-26 21:25 35 **************** ... ..( 4 skipped). .. **************** 106 2018-08-26 21:50 35 **************** 107 2018-08-26 21:55 36 ***************** 108 2018-08-26 22:00 37 ****************** 109 2018-08-26 22:05 36 ***************** 110 2018-08-26 22:10 35 **************** 111 2018-08-26 22:15 35 **************** 112 2018-08-26 22:20 34 *************** 113 2018-08-26 22:25 34 *************** 114 2018-08-26 22:30 34 *************** 115 2018-08-26 22:35 35 **************** ... ..( 7 skipped). .. **************** 123 2018-08-26 23:15 35 **************** 124 2018-08-26 23:20 36 ***************** ... ..( 3 skipped). .. ***************** 0 2018-08-26 23:40 36 ***************** 1 2018-08-26 23:45 35 **************** 2 2018-08-26 23:50 38 ******************* 3 2018-08-26 23:55 39 ******************** 4 2018-08-27 00:00 41 ********************** 5 2018-08-27 00:05 41 ********************** 6 2018-08-27 00:10 42 *********************** 7 2018-08-27 00:15 43 ************************ 8 2018-08-27 00:20 43 ************************ 9 2018-08-27 00:25 44 ************************* 10 2018-08-27 00:30 44 ************************* 11 2018-08-27 00:35 43 ************************ 12 2018-08-27 00:40 42 *********************** 13 2018-08-27 00:45 40 ********************* 14 2018-08-27 00:50 39 ******************** 15 2018-08-27 00:55 38 ******************* 16 2018-08-27 01:00 38 ******************* 17 2018-08-27 01:05 38 ******************* 18 2018-08-27 01:10 37 ****************** 19 2018-08-27 01:15 37 ****************** 20 2018-08-27 01:20 36 ***************** 21 2018-08-27 01:25 36 ***************** 22 2018-08-27 01:30 36 ***************** 23 2018-08-27 01:35 37 ****************** 24 2018-08-27 01:40 39 ******************** 25 2018-08-27 01:45 39 ******************** 26 2018-08-27 01:50 38 ******************* 27 2018-08-27 01:55 39 ******************** 28 2018-08-27 02:00 40 ********************* 29 2018-08-27 02:05 41 ********************** 30 2018-08-27 02:10 42 *********************** 31 2018-08-27 02:15 42 *********************** 32 2018-08-27 02:20 43 ************************ 33 2018-08-27 02:25 43 ************************ 34 2018-08-27 02:30 44 ************************* ... ..( 10 skipped). .. ************************* 45 2018-08-27 03:25 44 ************************* 46 2018-08-27 03:30 45 ************************** 47 2018-08-27 03:35 44 ************************* 48 2018-08-27 03:40 44 ************************* SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP/SMART Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0002 4 0 R_ERR response for data FIS 0x0003 4 0 R_ERR response for device-to-host data FIS 0x0004 4 0 R_ERR response for host-to-device data FIS 0x0005 4 0 R_ERR response for non-data FIS 0x0006 4 0 R_ERR response for device-to-host non-data FIS 0x0007 4 0 R_ERR response for host-to-device non-data FIS 0x0008 4 0 Device-to-host non-data FIS retries 0x0009 4 253289 Transition from drive PhyRdy to drive PhyNRdy 0x000a 4 14 Device-to-host register FISes sent due to a COMRESET 0x000b 4 0 CRC errors within host-to-device FIS 0x000d 4 0 Non-CRC errors within host-to-device FIS 0x000f 4 0 R_ERR response for host-to-device data FIS, CRC 0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC 0x8e00 4 0 Vendor specific 0x8e01 4 0 Vendor specific 0x8e02 4 0 Vendor specific 0x8e03 4 0 Vendor specific 0x8e04 4 0 Vendor specific 0x8e05 4 0 Vendor specific 0x8e06 4 0 Vendor specific 0x8e07 4 0 Vendor specific 0x8e08 4 0 Vendor specific 0x8e09 4 0 Vendor specific 0x8e0a 4 0 Vendor specific 0x8e0b 4 0 Vendor specific 0x8e0c 4 0 Vendor specific 0x8e0d 4 0 Vendor specific 0x8e0e 4 0 Vendor specific 0x8e0f 4 0 Vendor specific 0x8e10 4 0 Vendor specific 0x8e11 4 0 Vendor specific


Hardware for Linux and BSD

GitHub