Probe #c276874824 of System76 Darter Pro

Log: smartctl

/dev/nvme0n1 smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.13.11-200.fc41.x86_64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: Samsung SSD 980 PRO 1TB Serial Number: -- Firmware Version: 5B2QGXA7 PCI Vendor/Subsystem ID: 0x144d IEEE OUI Identifier: 0x002538 Total NVM Capacity: 1,000,204,886,016 [1.00 TB] Unallocated NVM Capacity: 0 Controller ID: 6 NVMe Version: 1.3 Number of Namespaces: 1 Namespace 1 Size/Capacity: 1,000,204,886,016 [1.00 TB] Namespace 1 Utilization: 397,159,718,912 [397 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 002538 ... Local Time is: Sun Apr 20 12:14:24 2025 CEST Firmware Updates (0x16): 3 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x0057): Comp Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp Log Page Attributes (0x0f): S/H_per_NS Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Maximum Data Transfer Size: 128 Pages Warning Comp. Temp. Threshold: 82 Celsius Critical Comp. Temp. Threshold: 85 Celsius Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 8.49W - - 0 0 0 0 0 0 1 + 4.48W - - 1 1 1 1 0 200 2 + 3.18W - - 2 2 2 2 0 1000 3 - 0.0400W - - 3 3 3 3 2000 1200 4 - 0.0050W - - 4 4 4 4 500 9500 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 24 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 1% Data Units Read: 33,951,085 [17.3 TB] Data Units Written: 25,306,863 [12.9 TB] Host Read Commands: 223,372,207 Host Write Commands: 333,779,977 Controller Busy Time: 2,315 Power Cycles: 491 Power On Hours: 173 Unsafe Shutdowns: 39 Media and Data Integrity Errors: 0 Error Information Log Entries: 0 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 24 Celsius Temperature Sensor 2: 22 Celsius Thermal Temp. 1 Transition Count: 1 Thermal Temp. 1 Total Time: 187 Error Information (NVMe Log 0x01, 16 of 64 entries) No Errors Logged Read Self-test Log failed: Invalid Field in Command (0x002) /dev/nvme1n1 smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.13.11-200.fc41.x86_64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: WD Blue SN580 2TB Serial Number: -- Firmware Version: 281050WD PCI Vendor/Subsystem ID: 0x15b7 IEEE OUI Identifier: 0x001b44 Total NVM Capacity: 2,000,398,934,016 [2.00 TB] Unallocated NVM Capacity: 0 Controller ID: 0 NVMe Version: 1.4 Number of Namespaces: 1 Namespace 1 Size/Capacity: 2,000,398,934,016 [2.00 TB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 001b44 ... Local Time is: Sun Apr 20 12:14:24 2025 CEST Firmware Updates (0x14): 2 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x00df): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp Verify Log Page Attributes (0x7e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg Log0_FISE_MI Telmtry_Ar_4 Maximum Data Transfer Size: 256 Pages Warning Comp. Temp. Threshold: 84 Celsius Critical Comp. Temp. Threshold: 88 Celsius Namespace 1 Features (0x02): NA_Fields Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 4.80W 4.80W - 0 0 0 0 0 0 1 + 3.50W 3.00W - 0 0 0 0 0 0 2 + 2.40W 2.00W - 0 0 0 0 0 0 3 - 0.0150W - - 3 3 3 3 1500 2500 4 - 0.0050W - - 4 4 4 4 10000 6000 5 - 0.0033W - - 5 5 5 5 176000 25000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 2 1 - 4096 0 1 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 21 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 0% Data Units Read: 3,437,196 [1.75 TB] Data Units Written: 7,001,711 [3.58 TB] Host Read Commands: 30,543,773 Host Write Commands: 99,524,945 Controller Busy Time: 96 Power Cycles: 67 Power On Hours: 29 Unsafe Shutdowns: 2 Media and Data Integrity Errors: 0 Error Information Log Entries: 0 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 32 Celsius Temperature Sensor 2: 21 Celsius Error Information (NVMe Log 0x01, 16 of 256 entries) No Errors Logged Read Self-test Log failed: Invalid Field in Command (0x4002) /dev/sda smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.13.11-200.fc41.x86_64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: CT500P3SSD8 Serial Number: -- Firmware Version: P9CR313 PCI Vendor/Subsystem ID: 0x1344 IEEE OUI Identifier: 0x00a075 Controller ID: 0 NVMe Version: 1.4 Number of Namespaces: 1 Namespace 1 Size/Capacity: 500,107,862,016 [500 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 00a075 ... Local Time is: Sun Apr 20 12:14:24 2025 CEST Firmware Updates (0x14): 2 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x00d7): Comp Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp Verify Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg Maximum Data Transfer Size: 64 Pages Warning Comp. Temp. Threshold: 83 Celsius Critical Comp. Temp. Threshold: 85 Celsius Namespace 1 Features (0x08): No_ID_Reuse Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 5.50W - - 0 0 0 0 0 0 1 + 3.00W - - 1 1 1 1 0 0 2 + 1.50W - - 2 2 2 2 0 0 3 - 0.0300W - - 3 3 3 3 5000 2500 4 - 0.0025W - - 4 4 4 4 8000 40000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 1 1 - 4096 0 0 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02) Critical Warning: 0x00 Temperature: 30 Celsius Available Spare: 100% Available Spare Threshold: 5% Percentage Used: 0% Data Units Read: 46,752 [23.9 GB] Data Units Written: 93,445 [47.8 GB] Host Read Commands: 3,969,277 Host Write Commands: 1,812,568 Controller Busy Time: 14 Power Cycles: 22 Power On Hours: 7 Unsafe Shutdowns: 11 Media and Data Integrity Errors: 0 Error Information Log Entries: 0 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 30 Celsius Warning: NVMe Get Log truncated to 0x200 bytes, 0x200 bytes zero filled Error Information (NVMe Log 0x01, 16 of 255 entries) No Errors Logged Warning: NVMe Get Log truncated to 0x200 bytes, 0x034 bytes zero filled Self-test Log (NVMe Log 0x06) Self-test status: No self-test in progress No Self-tests Logged


Hardware for Linux and BSD

GitHub