Probe #d2c7199739 of Dell XPS 17 9710
Log: smartctl
/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.8.0-55-generic] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: KXG70PNV2T04 NVMe KIOXIA 2048GB
Serial Number: --
Firmware Version: 10904107
PCI Vendor/Subsystem ID: 0x1e0f
IEEE OUI Identifier: 0x8ce38e
Total NVM Capacity: 2,048,408,248,320 [2.04 TB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 2,048,408,248,320 [2.04 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 8ce38e ...
Local Time is: Sun Mar 16 11:04:16 2025 EDT
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x00df): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp Verify
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Namespace 1 Features (0x02): NA_Fields
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 8.25W - - 0 0 0 0 1 1
1 + 5.90W - - 1 1 1 1 1 1
2 + 2.30W - - 2 2 2 2 1 1
3 - 0.1000W - - 3 3 3 3 1000 1200
4 - 0.0030W - - 4 4 4 4 10000 60000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 40 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 3%
Data Units Read: 82,643,770 [42.3 TB]
Data Units Written: 136,319,984 [69.7 TB]
Host Read Commands: 1,640,071,593
Host Write Commands: 3,235,110,252
Controller Busy Time: 6,115
Power Cycles: 792
Power On Hours: 26,075
Unsafe Shutdowns: 528
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 40 Celsius
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
0 Short Completed without error 24215 - - - - -
1 Short Completed without error 23767 - - - - -
2 Short Aborted: Self-test command 7471 - - - - -
3 Short Aborted: Controller Reset 1853 - - - - -
4 Short Aborted: Self-test command 40 - - - - -
5 Short Aborted: Self-test command 40 - - - - -
6 Short Completed without error 6 - - - - -
7 Short Completed without error 5 - - - - -