/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.6.27-generic-3rosa2021.1-x86_64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: XPG MARS 980 BLADE
Serial Number: --
Firmware Version: Y0218A
PCI Vendor/Subsystem ID: 0x1cc1
IEEE OUI Identifier: 0x0f8100
Total NVM Capacity: 1,024,209,543,168 [1.02 TB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 2.0
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,024,209,543,168 [1.02 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 0f8100 ...
Local Time is: Sun Aug 3 19:00:49 2025 MSK
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x00d7): Comp Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp Verify
Log Page Attributes (0x3a): Cmd_Eff_Lg Telmtry_Lg Pers_Ev_Lg Log0_FISE_MI
Maximum Data Transfer Size: 128 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Namespace 1 Features (0x0a): NA_Fields No_ID_Reuse
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 10.00W - - 0 0 0 0 0 0
1 + 4.00W - - 1 1 1 1 100000 100000
2 + 3.00W - - 2 2 2 2 50000 450000
3 - 0.0250W - - 3 3 3 3 5000 2500
4 - 0.0035W - - 4 4 4 4 5000 35000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 43 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 1%
Data Units Read: 51,601,220 [26.4 TB]
Data Units Written: 23,349,437 [11.9 TB]
Host Read Commands: 607,428,006
Host Write Commands: 756,635,475
Controller Busy Time: 2,425
Power Cycles: 168
Power On Hours: 929
Unsafe Shutdowns: 12
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 54 Celsius
Temperature Sensor 2: 43 Celsius
Error Information (NVMe Log 0x01, 16 of 256 entries)
No Errors Logged
Read Self-test Log failed: Invalid Field in Command (0x002)
/dev/sda
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.6.27-generic-3rosa2021.1-x86_64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Purple (Pro)
Device Model: WDC WD10PURX-64E5EY0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.01A01
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Device is: In smartctl database 7.3/5528
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Aug 3 19:00:49 2025 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (13980) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 159) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 143 132 021 - 3850
4 Start_Stop_Count -O--CK 096 096 000 - 4085
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
9 Power_On_Hours -O--CK 071 071 000 - 21654
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 097 097 000 - 3756
192 Power-Off_Retract_Count -O--CK 200 200 000 - 121
193 Load_Cycle_Count -O--CK 199 199 000 - 3963
194 Temperature_Celsius -O---K 110 092 000 - 33
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 2
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2 [1] occurred at disk power-on lifetime: 20630 hours (859 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 3a 00 08 00 40 00
Error: UNC at LBA = 0x3a000800 = 973080576
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 38 00 00 3b c0 08 00 40 08 00:01:53.995 READ FPDMA QUEUED
60 00 08 00 30 00 00 3b 80 08 00 40 08 00:01:53.995 READ FPDMA QUEUED
60 00 08 00 28 00 00 3b 40 08 00 40 08 00:01:53.995 READ FPDMA QUEUED
60 00 08 00 20 00 00 3b 00 08 00 40 08 00:01:53.995 READ FPDMA QUEUED
60 00 08 00 18 00 00 3a c0 08 00 40 08 00:01:53.995 READ FPDMA QUEUED
Error 1 [0] occurred at disk power-on lifetime: 20630 hours (859 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 5c 00 08 00 40 00
Error: UNC at LBA = 0x5c000800 = 1543505920
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 08 00 a8 00 00 5d c0 08 00 40 08 00:01:14.008 READ FPDMA QUEUED
60 00 08 00 a0 00 00 5d 80 08 00 40 08 00:01:14.008 READ FPDMA QUEUED
60 00 08 00 98 00 00 5d 40 08 00 40 08 00:01:14.008 READ FPDMA QUEUED
60 00 08 00 90 00 00 5d 00 08 00 40 08 00:01:14.008 READ FPDMA QUEUED
60 00 08 00 78 00 00 5c c0 08 00 40 08 00:01:14.008 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 28/35 Celsius
Lifetime Min/Max Temperature: 0/51 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
00 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 478 (150)
Index Estimated Time Temperature Celsius
151 2025-08-03 11:03 34 ***************
... ..( 79 skipped). .. ***************
231 2025-08-03 12:23 34 ***************
232 2025-08-03 12:24 35 ****************
... ..(252 skipped). .. ****************
7 2025-08-03 16:37 35 ****************
8 2025-08-03 16:38 34 ***************
... ..( 69 skipped). .. ***************
78 2025-08-03 17:48 34 ***************
79 2025-08-03 17:49 33 **************
... ..( 64 skipped). .. **************
144 2025-08-03 18:54 33 **************
145 2025-08-03 18:55 34 ***************
... ..( 4 skipped). .. ***************
150 2025-08-03 19:00 34 ***************
SCT Error Recovery Control:
Read: 70 (7.0 seconds)
Write: 70 (7.0 seconds)
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 3756 --- Lifetime Power-On Resets
0x01 0x010 4 21654 --- Power-on Hours
0x01 0x018 6 77528042771 --- Logical Sectors Written
0x01 0x020 6 888778394 --- Number of Write Commands
0x01 0x028 6 194408159215 --- Logical Sectors Read
0x01 0x030 6 1113652927 --- Number of Read Commands
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 21483 --- Spindle Motor Power-on Hours
0x03 0x010 4 21452 --- Head Flying Hours
0x03 0x018 4 4085 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 20 --- Read Recovery Attempts
0x03 0x030 4 0 --- Number of Mechanical Start Failures
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 2 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 1 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 33 --- Current Temperature
0x05 0x010 1 33 --- Average Short Term Temperature
0x05 0x018 1 32 --- Average Long Term Temperature
0x05 0x020 1 51 --- Highest Temperature
0x05 0x028 1 22 --- Lowest Temperature
0x05 0x030 1 45 --- Highest Average Short Term Temperature
0x05 0x038 1 26 --- Lowest Average Short Term Temperature
0x05 0x040 1 38 --- Highest Average Long Term Temperature
0x05 0x048 1 31 --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 60 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 12821 --- Number of Hardware Resets
0x06 0x010 4 4400 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 17 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 39901 Vendor specific