Probe #d6e00d590c of Gigabyte EG45M-DS2H Desktop Computer
Log: smartctl
/dev/sda
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.1-desktop-1omv2490] (OpenMandriva Lx 7.4-1)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Hitachi Deskstar P7K500
Device Model: Hitachi HDP725032GLA360
Serial Number: --
LU WWN Device Id: 5 000cca ...
Firmware Version: GM3OA52A
User Capacity: 320,071,851,520 bytes [320 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Fri Jan 17 22:47:11 2025 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 5908) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 98) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0
2 Throughput_Performance P-S--- 128 128 054 - 160
3 Spin_Up_Time POS--- 115 115 024 - 342 (Average 325)
4 Start_Stop_Count -O--C- 100 100 000 - 3709
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
8 Seek_Time_Performance P-S--- 131 131 020 - 29
9 Power_On_Hours -O--C- 099 099 000 - 11512
10 Spin_Retry_Count PO--C- 100 100 060 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 3575
192 Power-Off_Retract_Count -O--CK 097 097 000 - 3717
193 Load_Cycle_Count -O--C- 097 097 000 - 3717
194 Temperature_Celsius -O---- 176 176 000 - 34 (Min/Max 1/46)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O---K 100 100 000 - 0
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x20 GPL R/O 1 Streaming performance log
0x21 GPL R/O 1 Write stream error log
0x22 GPL R/O 1 Read stream error log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 22 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: 21/37 Celsius
Lifetime Min/Max Temperature: 1/46 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -40/70 Celsius
Temperature History Size (Index): 128 (100)
Index Estimated Time Temperature Celsius
101 2025-01-17 20:40 37 ******************
102 2025-01-17 20:41 37 ******************
103 2025-01-17 20:42 37 ******************
104 2025-01-17 20:43 36 *****************
105 2025-01-17 20:44 36 *****************
106 2025-01-17 20:45 37 ******************
107 2025-01-17 20:46 36 *****************
... ..( 10 skipped). .. *****************
118 2025-01-17 20:57 36 *****************
119 2025-01-17 20:58 37 ******************
120 2025-01-17 20:59 37 ******************
121 2025-01-17 21:00 37 ******************
122 2025-01-17 21:01 36 *****************
... ..( 4 skipped). .. *****************
127 2025-01-17 21:06 36 *****************
0 2025-01-17 21:07 37 ******************
1 2025-01-17 21:08 36 *****************
2 2025-01-17 21:09 36 *****************
3 2025-01-17 21:10 37 ******************
... ..( 7 skipped). .. ******************
11 2025-01-17 21:18 37 ******************
12 2025-01-17 21:19 36 *****************
... ..( 4 skipped). .. *****************
17 2025-01-17 21:24 36 *****************
18 2025-01-17 21:25 35 ****************
... ..( 8 skipped). .. ****************
27 2025-01-17 21:34 35 ****************
28 2025-01-17 21:35 34 ***************
... ..( 7 skipped). .. ***************
36 2025-01-17 21:43 34 ***************
37 2025-01-17 21:44 35 ****************
38 2025-01-17 21:45 34 ***************
... ..( 27 skipped). .. ***************
66 2025-01-17 22:13 34 ***************
67 2025-01-17 22:14 35 ****************
... ..( 7 skipped). .. ****************
75 2025-01-17 22:22 35 ****************
76 2025-01-17 22:23 34 ***************
... ..( 23 skipped). .. ***************
100 2025-01-17 22:47 34 ***************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 92 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS