/dev/sda
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.14.2-desktop-3omv2590] (OpenMandriva Lx 7.4-1)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: CT500BX500SSD1
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M6CR061
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available
Device is: Not in smartctl database
ATA Version is: ACS-3 T13/2161-D revision 4
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri May 2 02:29:21 2025 -05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x11) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
5 Reallocated_Sector_Ct -O--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 100 100 000 - 8449
12 Power_Cycle_Count -O--CK 100 100 000 - 3857
171 Unknown_Attribute -O--CK 100 100 000 - 0
172 Unknown_Attribute -O--CK 100 100 000 - 0
173 Unknown_Attribute -O--CK 097 097 000 - 34
174 Unknown_Attribute -O--CK 100 100 000 - 1166
180 Unused_Rsvd_Blk_Cnt_Tot PO--CK 100 100 000 - 41
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 067 057 000 - 33 (Min/Max 18/43)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
202 Unknown_SSD_Attribute ----CK 097 097 001 - 3
206 Unknown_SSD_Attribute -OSR-- 100 100 000 - 0
210 Unknown_Attribute -O--CK 100 100 000 - 0
246 Unknown_Attribute -O--CK 100 100 000 - 18510929407
247 Unknown_Attribute -O--CK 100 100 000 - 578466543
248 Unknown_Attribute -O--CK 100 100 000 - 1465829568
249 Unknown_Attribute -O--CK 100 100 000 - 0
251 Unknown_Attribute -O--CK 100 100 000 - 1062872635
252 Unknown_Attribute -O--CK 100 100 000 - 10
253 Unknown_Attribute -O--CK 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x24 GPL R/O 88 Current Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
Read SMART Error Log failed: scsi error badly formed scsi parameters
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Aborted by host 90% 6823 -
# 2 Short offline Aborted by host 90% 6823 -
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x000a 4 22 Device-to-host register FISes sent due to a COMRESET
/dev/sdb
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.14.2-desktop-3omv2590] (OpenMandriva Lx 7.4-1)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Scorpio Black
Device Model: WDC WD3200BEKT-60PVMT0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 01.01A01
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Form Factor: 2.5 inches
Device is: In smartctl database
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Fri May 2 02:29:21 2025 -05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 25) The self-test routine was aborted by
the host.
Total time to complete Offline
data collection: ( 6060) seconds.
Offline data collection
capabilities: (0x51) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 63) minutes.
SCT capabilities: (0x703d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 157 138 021 - 1141
4 Start_Stop_Count -O--CK 093 093 000 - 7575
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-K 100 253 051 - 0
9 Power_On_Hours -O--CK 064 064 000 - 26836
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 095 095 000 - 5505
183 Runtime_Bad_Block -O--CK 099 099 000 - 1
184 End-to-End_Error PO--CK 100 100 097 - 0
187 Reported_Uncorrect -O--CK 100 099 000 - 1
188 Command_Timeout -O--CK 100 091 000 - 38655295499
190 Airflow_Temperature_Cel -O---K 069 044 040 - 31 (Min/Max 30/33)
191 G-Sense_Error_Rate -O--CK 001 001 000 - 1185
192 Power-Off_Retract_Count -O--CK 200 200 000 - 102
193 Load_Cycle_Count -O--CK 148 148 000 - 157839
194 Temperature_Celsius -O---K 112 087 000 - 31
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate P--R-- 100 253 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 10
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 10 [9] occurred at disk power-on lifetime: 4822 hours (200 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 f7 df 38 a7 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
ea 00 00 00 00 00 00 00 00 00 00 e0 00 04:22:25.897 FLUSH CACHE EXT
61 00 08 00 a0 00 00 00 62 73 18 40 00 04:22:25.897 WRITE FPDMA QUEUED
61 00 01 00 98 00 00 00 7a 4c 38 40 00 04:22:25.897 WRITE FPDMA QUEUED
61 00 08 00 90 00 00 00 5b bd 70 40 00 04:22:25.897 WRITE FPDMA QUEUED
61 00 08 00 88 00 00 00 62 71 e0 40 00 04:22:25.896 WRITE FPDMA QUEUED
Error 9 [8] occurred at disk power-on lifetime: 4822 hours (200 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 f7 df 38 a7 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
ea 00 00 00 00 00 00 00 00 00 00 e0 00 04:22:17.179 FLUSH CACHE EXT
61 00 08 00 20 00 00 00 61 ee e8 40 00 04:22:17.179 WRITE FPDMA QUEUED
61 00 08 00 18 00 00 00 5b bd 68 40 00 04:22:17.179 WRITE FPDMA QUEUED
61 00 08 00 10 00 00 00 5b bd 80 40 00 04:22:17.178 WRITE FPDMA QUEUED
61 00 08 00 08 00 00 00 61 ec 98 40 00 04:22:17.178 WRITE FPDMA QUEUED
Error 8 [7] occurred at disk power-on lifetime: 4822 hours (200 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 f7 df 38 a7 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
ea 00 00 00 00 00 00 00 00 00 00 e0 00 04:22:08.017 FLUSH CACHE EXT
61 00 08 00 d8 00 00 00 5b bd 78 40 00 04:22:08.016 WRITE FPDMA QUEUED
61 00 10 00 d0 00 00 03 f2 4b d8 40 00 04:22:08.015 WRITE FPDMA QUEUED
61 00 08 00 c8 00 00 00 5f bd 68 40 00 04:22:07.662 WRITE FPDMA QUEUED
61 00 08 00 c0 00 00 00 5f c2 90 40 00 04:22:07.661 WRITE FPDMA QUEUED
Error 7 [6] occurred at disk power-on lifetime: 4822 hours (200 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 f7 df 38 a7 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
ea 00 00 00 00 00 00 00 00 00 00 e0 00 04:21:59.038 FLUSH CACHE EXT
61 00 08 00 f0 00 00 00 02 78 18 40 00 04:21:59.038 WRITE FPDMA QUEUED
61 00 10 00 e8 00 00 00 00 75 e0 40 00 04:21:59.038 WRITE FPDMA QUEUED
61 00 20 00 e0 00 00 00 5b d5 28 40 00 04:21:59.037 WRITE FPDMA QUEUED
61 00 08 00 d8 00 00 00 00 2a b8 40 00 04:21:59.037 WRITE FPDMA QUEUED
Error 6 [5] occurred at disk power-on lifetime: 4822 hours (200 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 00 00 00 00 40 00
Error: UNC at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 01 00 d8 00 00 00 00 00 00 40 00 04:21:40.710 READ FPDMA QUEUED
60 00 01 00 d0 00 00 00 2e 2d 92 40 00 04:21:40.650 READ FPDMA QUEUED
60 00 01 00 c8 00 00 00 2e 2d 92 40 00 04:21:40.650 READ FPDMA QUEUED
60 00 01 00 c0 00 00 00 2e 2d 92 40 00 04:21:40.650 READ FPDMA QUEUED
60 00 01 00 b8 00 00 00 2e 2d 92 40 00 04:21:40.649 READ FPDMA QUEUED
Error 5 [4] occurred at disk power-on lifetime: 4822 hours (200 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 f7 df 38 a7 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
ea 00 00 00 00 00 00 00 00 00 00 e0 00 03:34:02.270 FLUSH CACHE EXT
61 00 08 00 10 00 00 00 5b bd 80 40 00 03:34:02.269 WRITE FPDMA QUEUED
61 00 08 00 08 00 00 00 5b bd 68 40 00 03:34:02.269 WRITE FPDMA QUEUED
61 00 03 00 f8 00 00 00 0b ae 98 40 00 03:34:02.269 WRITE FPDMA QUEUED
61 00 40 00 f0 00 00 00 3a 7a c8 40 00 03:34:02.269 WRITE FPDMA QUEUED
Error 4 [3] occurred at disk power-on lifetime: 4822 hours (200 days + 22 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 f7 df 38 a7 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
ea 00 00 00 00 00 00 00 00 00 00 e0 00 03:33:52.514 FLUSH CACHE EXT
61 00 08 00 a8 00 00 00 61 e2 f8 40 00 03:33:52.514 WRITE FPDMA QUEUED
61 00 08 00 a0 00 00 00 5b bd 80 40 00 03:33:52.514 WRITE FPDMA QUEUED
61 00 08 00 98 00 00 00 61 de 20 40 00 03:33:52.514 WRITE FPDMA QUEUED
61 00 08 00 90 00 00 04 00 71 00 40 00 03:33:52.513 WRITE FPDMA QUEUED
Error 3 [2] occurred at disk power-on lifetime: 4819 hours (200 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 f7 df 38 a7 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
ea 00 00 00 00 00 00 00 00 00 00 e0 00 01:23:19.521 FLUSH CACHE EXT
61 00 08 00 38 00 00 00 5b bd 78 40 00 01:23:19.520 WRITE FPDMA QUEUED
e1 00 44 00 00 00 00 00 55 4e 4c e0 00 01:23:19.384 IDLE IMMEDIATE
e1 00 44 00 00 00 00 00 55 4e 4c e0 00 01:23:19.379 IDLE IMMEDIATE
61 00 10 00 28 00 00 00 5c b6 e8 40 00 01:23:19.378 WRITE FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Aborted by host 90% 24951 -
# 2 Short offline Interrupted (host reset) 90% 19343 -
# 3 Short offline Completed without error 00% 13338 -
# 4 Short offline Completed without error 00% 13320 -
# 5 Short offline Completed without error 00% 3659 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 31 Celsius
Power Cycle Min/Max Temperature: 30/33 Celsius
Lifetime Min/Max Temperature: 0/57 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (90)
Index Estimated Time Temperature Celsius
91 2025-05-02 00:22 31 ************
... ..( 48 skipped). .. ************
12 2025-05-02 01:11 31 ************
13 2025-05-02 01:12 30 ***********
... ..( 5 skipped). .. ***********
19 2025-05-02 01:18 30 ***********
20 2025-05-02 01:19 31 ************
... ..( 13 skipped). .. ************
34 2025-05-02 01:33 31 ************
35 2025-05-02 01:34 30 ***********
... ..( 12 skipped). .. ***********
48 2025-05-02 01:47 30 ***********
49 2025-05-02 01:48 31 ************
... ..( 23 skipped). .. ************
73 2025-05-02 02:12 31 ************
74 2025-05-02 02:13 32 *************
75 2025-05-02 02:14 32 *************
76 2025-05-02 02:15 31 ************
77 2025-05-02 02:16 32 *************
... ..( 6 skipped). .. *************
84 2025-05-02 02:23 32 *************
85 2025-05-02 02:24 31 ************
86 2025-05-02 02:25 32 *************
87 2025-05-02 02:26 31 ************
88 2025-05-02 02:27 32 *************
89 2025-05-02 02:28 32 *************
90 2025-05-02 02:29 31 ************
SCT Error Recovery Control:
Read: 85 (8.5 seconds)
Write: 85 (8.5 seconds)
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x8000 4 16359 Vendor specific