Probe #e1d0272f03 of Lenovo IdeaPad 100-15IBY 80...
Log: smartctl
/dev/sda
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.17.3-1-ARCH] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Blue Mobile
Device Model: WDC WD5000LPCX-24C6HT0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 02.01A02
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Wed Jul 4 14:26:48 2018 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 96 (intermediate level with standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 9000) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 104) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x7035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 151 146 021 - 1425
4 Start_Stop_Count -O--CK 093 093 000 - 7781
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-K 200 200 051 - 0
9 Power_On_Hours -O--CK 095 095 000 - 4314
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 099 099 000 - 1297
192 Power-Off_Retract_Count -O--CK 200 200 000 - 176
193 Load_Cycle_Count -O--CK 193 193 000 - 23142
194 Temperature_Celsius -O---K 113 097 000 - 30
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
240 Head_Flying_Hours -O--CK 095 095 000 - 3871
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
0xb7 GPL,SL VS 38 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 30/30 Celsius
Lifetime Min/Max Temperature: 16/46 Celsius
Lifetime Average Temperature: 30 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (124)
Index Estimated Time Temperature Celsius
125 2018-07-04 12:19 ? -
126 2018-07-04 12:20 35 ****************
127 2018-07-04 12:21 35 ****************
0 2018-07-04 12:22 ? -
1 2018-07-04 12:23 35 ****************
2 2018-07-04 12:24 35 ****************
3 2018-07-04 12:25 ? -
4 2018-07-04 12:26 35 ****************
5 2018-07-04 12:27 35 ****************
6 2018-07-04 12:28 ? -
7 2018-07-04 12:29 35 ****************
8 2018-07-04 12:30 35 ****************
9 2018-07-04 12:31 ? -
10 2018-07-04 12:32 35 ****************
11 2018-07-04 12:33 35 ****************
12 2018-07-04 12:34 ? -
13 2018-07-04 12:35 35 ****************
14 2018-07-04 12:36 35 ****************
15 2018-07-04 12:37 35 ****************
16 2018-07-04 12:38 ? -
17 2018-07-04 12:39 35 ****************
18 2018-07-04 12:40 35 ****************
19 2018-07-04 12:41 35 ****************
20 2018-07-04 12:42 ? -
21 2018-07-04 12:43 35 ****************
22 2018-07-04 12:44 35 ****************
23 2018-07-04 12:45 ? -
24 2018-07-04 12:46 35 ****************
25 2018-07-04 12:47 35 ****************
26 2018-07-04 12:48 ? -
27 2018-07-04 12:49 35 ****************
28 2018-07-04 12:50 35 ****************
29 2018-07-04 12:51 ? -
30 2018-07-04 12:52 35 ****************
31 2018-07-04 12:53 35 ****************
32 2018-07-04 12:54 ? -
33 2018-07-04 12:55 35 ****************
34 2018-07-04 12:56 35 ****************
35 2018-07-04 12:57 ? -
36 2018-07-04 12:58 35 ****************
37 2018-07-04 12:59 35 ****************
38 2018-07-04 13:00 35 ****************
39 2018-07-04 13:01 ? -
40 2018-07-04 13:02 35 ****************
41 2018-07-04 13:03 35 ****************
42 2018-07-04 13:04 ? -
43 2018-07-04 13:05 35 ****************
... ..( 2 skipped). .. ****************
46 2018-07-04 13:08 35 ****************
47 2018-07-04 13:09 ? -
48 2018-07-04 13:10 35 ****************
... ..( 3 skipped). .. ****************
52 2018-07-04 13:14 35 ****************
53 2018-07-04 13:15 36 *****************
... ..( 10 skipped). .. *****************
64 2018-07-04 13:26 36 *****************
65 2018-07-04 13:27 37 ******************
66 2018-07-04 13:28 36 *****************
... ..( 13 skipped). .. *****************
80 2018-07-04 13:42 36 *****************
81 2018-07-04 13:43 ? -
82 2018-07-04 13:44 24 *****
83 2018-07-04 13:45 25 ******
84 2018-07-04 13:46 26 *******
85 2018-07-04 13:47 27 ********
86 2018-07-04 13:48 27 ********
87 2018-07-04 13:49 28 *********
88 2018-07-04 13:50 29 **********
89 2018-07-04 13:51 30 ***********
90 2018-07-04 13:52 30 ***********
91 2018-07-04 13:53 30 ***********
92 2018-07-04 13:54 31 ************
93 2018-07-04 13:55 32 *************
94 2018-07-04 13:56 32 *************
95 2018-07-04 13:57 33 **************
96 2018-07-04 13:58 34 ***************
... ..( 5 skipped). .. ***************
102 2018-07-04 14:04 34 ***************
103 2018-07-04 14:05 35 ****************
... ..( 2 skipped). .. ****************
106 2018-07-04 14:08 35 ****************
107 2018-07-04 14:09 36 *****************
... ..( 2 skipped). .. *****************
110 2018-07-04 14:12 36 *****************
111 2018-07-04 14:13 35 ****************
... ..( 6 skipped). .. ****************
118 2018-07-04 14:20 35 ****************
119 2018-07-04 14:21 ? -
120 2018-07-04 14:22 30 ***********
121 2018-07-04 14:23 ? -
122 2018-07-04 14:24 30 ***********
123 2018-07-04 14:25 ? -
124 2018-07-04 14:26 30 ***********
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 151 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 61 Vendor specific