Probe #e4a66b20cf of Lenovo V580 20147
Log: smartctl
/dev/sda
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Scorpio Blue Serial ATA (AF)
Device Model: WDC WD5000BPVT-08HXZT3
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 03.01A03
User Capacity: 500 107 862 016 bytes [500 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 1.5 Gb/s (current: 1.5 Gb/s)
Local Time is: Tue May 9 22:43:28 2017 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 96 (intermediate level with standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (12000) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 119) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x7035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 189 173 021 - 1541
4 Start_Stop_Count -O--CK 078 078 000 - 22833
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate POSR-K 200 200 051 - 0
9 Power_On_Hours -O--CK 088 088 000 - 9042
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 2218
192 Power-Off_Retract_Count -O--CK 200 200 000 - 43
193 Load_Cycle_Count -O--CK 176 176 000 - 73368
194 Temperature_Celsius -O---K 111 093 000 - 36
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
240 Head_Flying_Hours -O--CK 088 088 000 - 8935
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 SATA NCQ Queued Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xbd GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 93 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 6115 -
# 2 Short offline Completed without error 00% 6114 -
# 3 Short offline Completed without error 00% 6111 -
# 4 Vendor (0x50) Completed without error 00% 4695 -
# 5 Short offline Completed without error 00% 4695 -
# 6 Vendor (0x50) Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 36/37 Celsius
Lifetime Min/Max Temperature: 0/54 Celsius
Lifetime Average Temperature: 27 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (85)
Index Estimated Time Temperature Celsius
86 2017-05-09 20:36 36 *****************
... ..( 7 skipped). .. *****************
94 2017-05-09 20:44 36 *****************
95 2017-05-09 20:45 37 ******************
... ..( 3 skipped). .. ******************
99 2017-05-09 20:49 37 ******************
100 2017-05-09 20:50 38 *******************
101 2017-05-09 20:51 ? -
102 2017-05-09 20:52 38 *******************
103 2017-05-09 20:53 ? -
104 2017-05-09 20:54 36 *****************
... ..( 5 skipped). .. *****************
110 2017-05-09 21:00 36 *****************
111 2017-05-09 21:01 ? -
112 2017-05-09 21:02 36 *****************
... ..( 19 skipped). .. *****************
4 2017-05-09 21:22 36 *****************
5 2017-05-09 21:23 ? -
6 2017-05-09 21:24 36 *****************
7 2017-05-09 21:25 ? -
8 2017-05-09 21:26 36 *****************
9 2017-05-09 21:27 37 ******************
10 2017-05-09 21:28 37 ******************
11 2017-05-09 21:29 ? -
12 2017-05-09 21:30 37 ******************
... ..( 15 skipped). .. ******************
28 2017-05-09 21:46 37 ******************
29 2017-05-09 21:47 36 *****************
... ..( 6 skipped). .. *****************
36 2017-05-09 21:54 36 *****************
37 2017-05-09 21:55 ? -
38 2017-05-09 21:56 36 *****************
39 2017-05-09 21:57 36 *****************
40 2017-05-09 21:58 ? -
41 2017-05-09 21:59 36 *****************
42 2017-05-09 22:00 36 *****************
43 2017-05-09 22:01 ? -
44 2017-05-09 22:02 36 *****************
45 2017-05-09 22:03 36 *****************
46 2017-05-09 22:04 37 ******************
... ..( 11 skipped). .. ******************
58 2017-05-09 22:16 37 ******************
59 2017-05-09 22:17 36 *****************
... ..( 23 skipped). .. *****************
83 2017-05-09 22:41 36 *****************
84 2017-05-09 22:42 ? -
85 2017-05-09 22:43 36 *****************
SCT Error Recovery Control command not supported
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 10 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 5647 Vendor specific