/dev/sda
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Scorpio Blue Serial ATA
Device Model: WDC WD3200BEVT-22ZCT0
Serial Number: --
LU WWN Device Id: 5 0014ee ...
Firmware Version: 11.01A11
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Sun Jan 15 22:06:08 2017 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 128
APM level is: 128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
See vendor-specific Attribute list for failed Attributes.
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 9960) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 118) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 199 051 - 25
3 Spin_Up_Time POS--K 186 185 021 - 1675
4 Start_Stop_Count -O--CK 095 095 000 - 5109
5 Reallocated_Sector_Ct PO--CK 029 029 140 NOW 1365
7 Seek_Error_Rate -OSR-K 001 001 000 - 7547
9 Power_On_Hours -O--CK 096 096 000 - 3169
10 Spin_Retry_Count PO--CK 100 100 051 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 096 096 000 - 4704
192 Power-Off_Retract_Count -O--CK 197 197 000 - 2274
193 Load_Cycle_Count -O--CK 185 185 000 - 46303
194 Temperature_Celsius -O---K 120 079 000 - 27
196 Reallocated_Event_Count -O--CK 194 194 000 - 6
197 Current_Pending_Sector -O--CK 200 198 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 78
200 Multi_Zone_Error_Rate P--R-- 100 253 051 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 SATA NCQ Queued Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 1 Device vendor specific log
0xc1 GPL VS 24 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
Device Error Count: 55187 (device log contains only the most recent 24 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 55187 [2] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 00 01 ff 00 41 00 00 e0 01 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 de 42 07 2a 00 00 00 00 00 00 00 1c 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
00 ff 00 00 35 07 02 1c 1d 42 00 00 00 00:00:13.567 NOP [Abort queued commands]
1c 4f 42 07 1c 00 ff 00 36 00 00 00 1c 00:07:46.177 RECALIBRATE [RET-4]
00 ff 00 00 38 07 a0 1c 10 42 00 00 00 00:00:14.335 NOP [Abort queued commands]
Error 55186 [1] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 00 01 ff 00 51 00 00 e0 01 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 02 42 07 1d 00 00 00 00 00 00 00 1c 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
00 ff 00 00 36 07 01 1c 1d 42 00 00 00 00:00:13.823 NOP [Abort queued commands]
1c a0 42 07 10 00 ff 00 37 00 00 00 1c 00:07:45.999 RECALIBRATE [RET-4]
00 ff 00 00 39 07 04 1c 05 42 00 00 00 00:00:14.591 NOP [Abort queued commands]
Error 55185 [0] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
01 -- 00 01 ff 00 51 00 00 e0 01 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 a0 42 07 10 00 00 00 00 00 00 00 1c 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
00 ff 00 00 39 07 04 1c 05 42 00 00 00 00:00:14.591 NOP [Abort queued commands]
1c ed 42 07 04 00 ff 00 3a 00 00 00 1c 00:07:40.033 RECALIBRATE [RET-4]
00 ff 00 00 3c 06 59 1c f5 42 00 00 00 00:00:15.359 NOP [Abort queued commands]
Error 55184 [23] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 00 01 ff 00 51 00 00 e0 01 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 04 42 07 05 00 00 00 00 00 00 00 1c 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
00 ff 00 00 3a 07 01 1c 05 42 00 00 00 00:00:14.847 NOP [Abort queued commands]
1c 59 42 06 f5 00 ff 00 3b 00 00 00 1c 00:07:40.013 RECALIBRATE [RET-4]
00 ff 00 00 3d 06 57 1c f5 42 00 00 00 00:00:15.615 NOP [Abort queued commands]
Error 55183 [22] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 00 01 ff 00 51 00 00 e0 01 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 59 42 06 f5 00 00 00 00 00 00 00 1c 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
00 ff 00 00 3d 06 57 1c f5 42 00 00 00 00:00:15.615 NOP [Abort queued commands]
1c 3f 42 06 f5 00 ff 00 3e 00 00 00 1c 00:07:36.019 RECALIBRATE [RET-4]
00 ff 00 00 40 06 91 1c e9 42 00 00 00 00:00:16.383 NOP [Abort queued commands]
Error 55182 [21] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 00 01 ff 00 51 00 00 e0 01 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 91 42 06 e9 00 00 00 00 00 00 00 1c 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
00 ff 00 00 41 06 8f 1c e9 42 00 00 00 00:00:16.639 NOP [Abort queued commands]
1c 7a 42 06 e9 00 ff 00 42 00 00 00 1c 00:07:33.003 RECALIBRATE [RET-4]
00 ff 00 00 44 06 00 1c de 42 00 00 00 00:00:17.407 NOP [Abort queued commands]
Error 55181 [20] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 00 01 ff 00 51 00 00 e0 01 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 00 42 06 de 00 00 00 00 00 00 00 1c 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
00 ff 00 00 45 06 fe 1c dd 42 00 00 00 00:00:17.663 NOP [Abort queued commands]
1c 96 42 06 d8 00 ff 00 46 00 00 00 1c 00:07:30.039 RECALIBRATE [RET-4]
00 ff 00 00 48 06 3d 1c cd 42 00 00 00 00:00:18.431 NOP [Abort queued commands]
Error 55180 [19] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 00 01 ff 00 41 00 00 e0 01 00 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
00 96 42 06 d8 00 00 00 00 00 00 00 1c 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
00 ff 00 00 48 06 3d 1c cd 42 00 00 00 00:00:18.431 NOP [Abort queued commands]
1c 2e 42 06 cd 00 ff 00 49 00 00 00 1c 00:07:25.755 RECALIBRATE [RET-4]
00 ff 00 00 4b 06 d0 1c c7 42 00 00 00 00:00:19.199 NOP [Abort queued commands]
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Conveyance offline Completed: unknown failure 90% 2995 4294967295
# 2 Short offline Completed: unknown failure 90% 2995 4294967295
# 3 Short offline Completed: unknown failure 90% 2985 4294967295
# 4 Short offline Completed: unknown failure 90% 2985 4294967295
# 5 Short offline Completed: unknown failure 90% 2985 4294967295
# 6 Short offline Aborted by host 10% 2984 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
SCT Support Level: 1
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 27 Celsius
Power Cycle Min/Max Temperature: 19/28 Celsius
Lifetime Min/Max Temperature: 18/69 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: 1/85 Celsius
Temperature History Size (Index): 128 (123)
Index Estimated Time Temperature Celsius
124 2017-01-15 19:59 25 ******
125 2017-01-15 20:00 ? -
126 2017-01-15 20:01 19 -
127 2017-01-15 20:02 19 -
0 2017-01-15 20:03 20 *
1 2017-01-15 20:04 20 *
2 2017-01-15 20:05 21 **
3 2017-01-15 20:06 22 ***
4 2017-01-15 20:07 22 ***
5 2017-01-15 20:08 22 ***
6 2017-01-15 20:09 23 ****
7 2017-01-15 20:10 23 ****
8 2017-01-15 20:11 23 ****
9 2017-01-15 20:12 24 *****
10 2017-01-15 20:13 24 *****
11 2017-01-15 20:14 25 ******
... ..( 6 skipped). .. ******
18 2017-01-15 20:21 25 ******
19 2017-01-15 20:22 26 *******
... ..( 8 skipped). .. *******
28 2017-01-15 20:31 26 *******
29 2017-01-15 20:32 27 ********
30 2017-01-15 20:33 27 ********
31 2017-01-15 20:34 27 ********
32 2017-01-15 20:35 ? -
33 2017-01-15 20:36 19 -
34 2017-01-15 20:37 ? -
35 2017-01-15 20:38 19 -
36 2017-01-15 20:39 20 *
37 2017-01-15 20:40 21 **
38 2017-01-15 20:41 21 **
39 2017-01-15 20:42 22 ***
40 2017-01-15 20:43 22 ***
41 2017-01-15 20:44 23 ****
42 2017-01-15 20:45 23 ****
43 2017-01-15 20:46 23 ****
44 2017-01-15 20:47 24 *****
45 2017-01-15 20:48 24 *****
46 2017-01-15 20:49 24 *****
47 2017-01-15 20:50 25 ******
... ..( 3 skipped). .. ******
51 2017-01-15 20:54 25 ******
52 2017-01-15 20:55 26 *******
... ..( 3 skipped). .. *******
56 2017-01-15 20:59 26 *******
57 2017-01-15 21:00 27 ********
... ..( 38 skipped). .. ********
96 2017-01-15 21:39 27 ********
97 2017-01-15 21:40 28 *********
... ..( 8 skipped). .. *********
106 2017-01-15 21:49 28 *********
107 2017-01-15 21:50 27 ********
... ..( 15 skipped). .. ********
123 2017-01-15 22:06 27 ********
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
0x8000 4 5352 Vendor specific
/dev/sdb
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus
Device Model: ST380011A
Serial Number: --
Firmware Version: 8.01
User Capacity: 80,026,361,856 bytes [80,0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-6 T13/1410D revision 2
Local Time is: Sun Jan 15 22:06:09 2017 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 58) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 064 055 006 - 181290722
3 Spin_Up_Time PO---- 099 098 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 151
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 086 060 030 - 448494187
9 Power_On_Hours -O--CK 093 093 000 - 6815
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 098 098 020 - 2258
194 Temperature_Celsius -O---K 033 052 000 - 33
195 Hardware_ECC_Recovered -O-RC- 064 055 000 - 181290722
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 093 000 - 3064
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xff GPL - 24064 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 236 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 236 [15] occurred at disk power-on lifetime: 6806 hours (283 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 00 00 00 00 f0 00
Error: ICRC, ABRT 1 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 f0 00 00:00:32.980 READ DMA
ef 00 03 00 42 00 ff ff 00 ff ff b0 00 00:00:32.957 SET FEATURES [Set transfer mode]
ec 00 00 01 00 00 ff ff 00 ff ff b0 00 00:00:32.889 IDENTIFY DEVICE
00 00 00 01 00 00 00 1f 00 00 7f 00 00 00:00:25.927 NOP [Abort queued commands]
00 00 00 01 00 00 00 1f 00 00 7f 00 00 00:00:25.917 NOP [Abort queued commands]
Error 235 [14] occurred at disk power-on lifetime: 6806 hours (283 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 00 00 00 00 f0 00
Error: ICRC, ABRT 1 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 f0 00 00:00:06.819 READ DMA
ef 00 03 00 42 00 ff ff 00 ff ff b0 00 00:00:06.812 SET FEATURES [Set transfer mode]
ec 00 00 01 00 00 ff ff 00 ff ff b0 00 00:00:06.630 IDENTIFY DEVICE
00 00 00 00 01 00 00 00 00 00 00 00 00 00:00:25.927 NOP [Abort queued commands]
00 00 00 00 01 00 00 00 00 00 00 00 00 00:00:25.917 NOP [Abort queued commands]
Error 234 [13] occurred at disk power-on lifetime: 6806 hours (283 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 00 00 00 00 f0 00
Error: ICRC, ABRT 1 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 f0 00 00:00:06.819 READ DMA
ef 00 03 00 42 00 ff ff 00 ff ff b0 00 00:00:06.812 SET FEATURES [Set transfer mode]
ec 00 00 01 00 00 ff ff 00 ff ff b0 00 00:00:06.630 IDENTIFY DEVICE
00 00 00 00 00 00 00 00 00 00 00 00 00 00:00:05.317 NOP [Abort queued commands]
Error 233 [12] occurred at disk power-on lifetime: 6806 hours (283 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 00 00 00 00 e0 00
Error: ICRC, ABRT 1 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 e0 00 00:00:52.043 READ DMA
ef 00 03 00 42 00 ff ff 00 ff ff a0 00 00:00:52.043 SET FEATURES [Set transfer mode]
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:00:52.043 IDENTIFY DEVICE
00 00 00 00 01 00 00 00 00 00 00 00 00 00:00:52.039 NOP [Abort queued commands]
00 00 00 00 01 00 00 00 00 00 00 00 00 00:00:52.039 NOP [Abort queued commands]
Error 232 [11] occurred at disk power-on lifetime: 6806 hours (283 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 00 00 00 00 f0 00
Error: ICRC, ABRT 1 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 f0 00 00:00:32.980 READ DMA
ef 00 03 00 42 00 ff ff 00 ff ff b0 00 00:00:32.957 SET FEATURES [Set transfer mode]
ec 00 00 01 00 00 ff ff 00 ff ff b0 00 00:00:32.889 IDENTIFY DEVICE
00 00 00 01 00 00 00 1f 00 00 7f 00 00 00:00:25.927 NOP [Abort queued commands]
00 00 00 01 00 00 00 1f 00 00 7f 00 00 00:00:25.917 NOP [Abort queued commands]
Error 231 [10] occurred at disk power-on lifetime: 6806 hours (283 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 00 00 00 00 f0 00
Error: ICRC, ABRT 1 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 f0 00 00:00:06.819 READ DMA
ef 00 03 00 42 00 ff ff 00 ff ff b0 00 00:00:06.812 SET FEATURES [Set transfer mode]
ec 00 00 01 00 00 ff ff 00 ff ff b0 00 00:00:06.630 IDENTIFY DEVICE
00 00 00 00 01 00 00 00 00 00 00 00 00 00:00:25.927 NOP [Abort queued commands]
00 00 00 00 01 00 00 00 00 00 00 00 00 00:00:25.917 NOP [Abort queued commands]
Error 230 [9] occurred at disk power-on lifetime: 6806 hours (283 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 00 00 00 00 f0 00
Error: ICRC, ABRT 1 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 f0 00 00:00:06.819 READ DMA
ef 00 03 00 42 00 ff ff 00 ff ff b0 00 00:00:06.812 SET FEATURES [Set transfer mode]
ec 00 00 01 00 00 ff ff 00 ff ff b0 00 00:00:06.630 IDENTIFY DEVICE
00 00 00 00 00 00 00 00 00 00 00 00 00 00:00:05.317 NOP [Abort queued commands]
Error 229 [8] occurred at disk power-on lifetime: 6806 hours (283 days + 14 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
84 -- 51 00 01 00 00 00 00 00 00 e0 00
Error: ICRC, ABRT 1 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 01 00 00 00 00 00 00 e0 00 00:00:52.043 READ DMA
ef 00 03 00 42 00 ff ff 00 ff ff a0 00 00:00:52.043 SET FEATURES [Set transfer mode]
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:00:52.043 IDENTIFY DEVICE
00 00 00 00 01 00 00 00 00 00 00 00 00 00:00:52.039 NOP [Abort queued commands]
00 00 00 00 01 00 00 00 00 00 00 00 00 00:00:52.039 NOP [Abort queued commands]
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11) not supported