Probe #edb1d110e2 of MECHREVO S2 Air Series PF4NU1...
Log: smartctl
/dev/nvme0n1
smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.6.8-zen1-1-zen] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: SAMSUNG MZVLB512HAJQ-00000
Serial Number: --
Firmware Version: EXA7301Q
PCI Vendor/Subsystem ID: 0x144d
IEEE OUI Identifier: 0x002538
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 4
NVMe Version: 1.2
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Utilization: 393,911,492,608 [393 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 002538 ...
Local Time is: Mon Dec 25 15:39:47 2023 CST
Firmware Updates (0x16): 3 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 81 Celsius
Critical Comp. Temp. Threshold: 82 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.02W - - 0 0 0 0 0 0
1 + 6.30W - - 1 1 1 1 0 0
2 + 3.50W - - 2 2 2 2 0 0
3 - 0.0760W - - 3 3 3 3 210 1200
4 - 0.0050W - - 4 4 4 4 2000 8000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 30 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 7%
Data Units Read: 60,832,897 [31.1 TB]
Data Units Written: 86,227,055 [44.1 TB]
Host Read Commands: 646,301,056
Host Write Commands: 843,543,028
Controller Busy Time: 3,107
Power Cycles: 3,146
Power On Hours: 1,877
Unsafe Shutdowns: 293
Media and Data Integrity Errors: 0
Error Information Log Entries: 19,393
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 30 Celsius
Temperature Sensor 2: 41 Celsius
Error Information (NVMe Log 0x01, 16 of 64 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 19393 0 0x0010 0x4004 - 0 0 - Invalid Field in Command
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged