/dev/sda
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.1-desktop-1omv2290] (OpenMandriva Lx 7.3-2)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint F3
Device Model: SAMSUNG HD502HJ
Serial Number: --
LU WWN Device Id: 5 0024e9 ...
Firmware Version: 1AJ10001
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database
ATA Version is: ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Fri Mar 3 12:10:58 2023 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 254
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 4800) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 80) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 28990
2 Throughput_Performance -OS--K 252 252 000 - 0
3 Spin_Up_Time PO---K 082 070 025 - 5458
4 Start_Stop_Count -O--CK 088 088 000 - 12488
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
8 Seek_Time_Performance --S--K 252 252 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 35757
10 Spin_Retry_Count -O--CK 252 252 051 - 0
11 Calibration_Retry_Count -O--CK 252 252 000 - 0
12 Power_Cycle_Count -O--CK 097 097 000 - 3370
191 G-Sense_Error_Rate -O---K 252 252 000 - 0
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
194 Temperature_Celsius -O---- 064 060 000 - 29 (Min/Max 14/40)
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 14
198 Offline_Uncorrectable ----CK 252 252 000 - 0
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 16
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 11
223 Load_Retry_Count -O--CK 252 252 000 - 0
225 Load_Cycle_Count -O--CK 099 099 000 - 12915
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 2 Extended self-test log
0x08 GPL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Device Error Count: 20284 (device log contains only the most recent 8 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 20284 [3] occurred at disk power-on lifetime: 35659 hours (1485 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 04 00 00 00 03 28 04 40 00
Error: UNC at LBA = 0x00032804 = 206852
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 04 00 00 00 03 28 04 40 08 00:00:01.596 READ FPDMA QUEUED
60 00 03 00 04 00 00 00 03 28 04 40 08 00:00:01.719 READ FPDMA QUEUED
60 00 10 00 08 00 00 33 07 ec 00 40 08 00:00:01.719 READ FPDMA QUEUED
60 00 00 00 08 00 00 36 72 f2 00 40 08 00:00:01.719 READ FPDMA QUEUED
60 00 00 00 08 00 00 13 41 f8 00 40 08 00:00:01.719 READ FPDMA QUEUED
Error 20283 [2] occurred at disk power-on lifetime: 35659 hours (1485 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 02 00 00 00 03 28 02 40 00
Error: UNC at LBA = 0x00032802 = 206850
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 03 00 02 00 00 00 03 28 02 40 08 00:00:01.702 READ FPDMA QUEUED
60 00 10 00 02 00 00 00 03 28 02 40 08 00:00:01.718 READ FPDMA QUEUED
60 00 00 00 08 00 00 36 72 f2 00 40 08 00:00:01.718 READ FPDMA QUEUED
60 00 00 00 08 00 00 13 41 f8 00 40 08 00:00:01.718 READ FPDMA QUEUED
60 00 00 00 02 00 00 00 03 28 00 40 08 00:00:01.718 READ FPDMA QUEUED
Error 20282 [1] occurred at disk power-on lifetime: 35659 hours (1485 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 04 00 00 00 03 28 04 40 00
Error: UNC at LBA = 0x00032804 = 206852
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 03 00 08 00 00 00 03 28 00 40 08 00:00:01.697 READ FPDMA QUEUED
60 00 10 00 08 00 00 36 72 f1 00 40 08 00:00:01.715 READ FPDMA QUEUED
60 00 00 00 08 00 00 33 07 e9 00 40 08 00:00:01.715 READ FPDMA QUEUED
60 00 00 00 08 00 00 32 8a e0 80 40 08 00:00:01.715 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 03 28 00 40 08 00:00:01.715 READ FPDMA QUEUED
Error 20281 [0] occurred at disk power-on lifetime: 35659 hours (1485 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 04 00 00 00 03 27 84 40 00
Error: UNC at LBA = 0x00032784 = 206724
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 00 03 27 80 40 08 00:00:01.695 READ FPDMA QUEUED
60 00 10 00 08 00 00 00 03 27 80 40 08 00:00:01.711 READ FPDMA QUEUED
60 00 10 00 08 00 00 33 07 e8 40 40 08 00:00:01.711 READ FPDMA QUEUED
60 00 10 00 08 00 00 36 72 f0 40 40 08 00:00:01.711 READ FPDMA QUEUED
60 00 10 00 08 00 00 32 8a e0 20 40 08 00:00:01.711 READ FPDMA QUEUED
Error 20280 [7] occurred at disk power-on lifetime: 35659 hours (1485 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 04 00 00 00 03 27 84 40 00
Error: UNC at LBA = 0x00032784 = 206724
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 10 00 08 00 00 00 03 27 80 40 08 00:00:01.598 READ FPDMA QUEUED
60 00 10 00 08 00 00 32 8a e0 20 40 08 00:00:01.707 READ FPDMA QUEUED
60 00 00 00 08 00 00 36 72 f0 40 40 08 00:00:01.707 READ FPDMA QUEUED
60 00 10 00 08 00 00 33 07 e8 40 40 08 00:00:01.707 READ FPDMA QUEUED
60 00 00 00 08 00 00 00 03 27 80 40 08 00:00:01.707 READ FPDMA QUEUED
Error 20279 [6] occurred at disk power-on lifetime: 35659 hours (1485 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 02 00 00 00 03 28 06 40 00
Error: UNC at LBA = 0x00032806 = 206854
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 10 00 02 00 00 00 03 28 06 40 08 00:00:01.598 READ FPDMA QUEUED
60 00 10 00 02 00 00 00 03 28 06 40 08 00:00:01.706 READ FPDMA QUEUED
ef 00 10 00 02 00 00 00 00 00 00 a0 08 00:00:01.706 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 00 00 00 00 00 e0 08 00:00:01.706 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 00 00 00 00 00 a0 08 00:00:01.706 IDENTIFY DEVICE
Error 20278 [5] occurred at disk power-on lifetime: 35659 hours (1485 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 02 00 00 00 03 28 04 40 00
Error: UNC at LBA = 0x00032804 = 206852
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 10 00 02 00 00 00 03 28 04 40 08 00:00:01.597 READ FPDMA QUEUED
60 00 10 00 02 00 00 00 03 28 06 40 08 00:00:01.704 READ FPDMA QUEUED
60 00 10 00 02 00 00 00 03 28 04 40 08 00:00:01.704 READ FPDMA QUEUED
60 00 10 00 02 00 00 00 03 28 02 40 08 00:00:01.704 READ FPDMA QUEUED
60 00 10 00 08 00 00 32 8a e0 00 40 08 00:00:01.704 READ FPDMA QUEUED
Error 20277 [4] occurred at disk power-on lifetime: 35659 hours (1485 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 04 00 00 00 03 28 04 40 00
Error: WP at LBA = 0x00032804 = 206852
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 10 00 08 00 00 13 b9 28 00 40 08 00:00:01.704 WRITE FPDMA QUEUED
60 00 00 00 08 00 00 00 03 28 00 40 08 00:00:01.596 READ FPDMA QUEUED
60 00 03 00 08 00 00 33 07 e8 00 40 08 00:00:01.702 READ FPDMA QUEUED
60 00 10 00 08 00 00 32 8a e0 00 40 08 00:00:01.702 READ FPDMA QUEUED
60 00 00 00 08 00 00 36 72 f0 00 40 08 00:00:01.702 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (2 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed [00% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 29 Celsius
Power Cycle Min/Max Temperature: 26/29 Celsius
Lifetime Min/Max Temperature: 18/63 Celsius
Specified Max Operating Temperature: 80 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 5 minutes
Temperature Logging Interval: 5 minutes
Min/Max recommended Temperature: -5/80 Celsius
Min/Max Temperature Limit: -10/85 Celsius
Temperature History Size (Index): 128 (84)
Index Estimated Time Temperature Celsius
85 2023-03-03 01:35 28 *********
... ..( 49 skipped). .. *********
7 2023-03-03 05:45 28 *********
8 2023-03-03 05:50 26 *******
9 2023-03-03 05:55 27 ********
... ..( 2 skipped). .. ********
12 2023-03-03 06:10 27 ********
13 2023-03-03 06:15 28 *********
14 2023-03-03 06:20 27 ********
15 2023-03-03 06:25 28 *********
... ..( 8 skipped). .. *********
24 2023-03-03 07:10 28 *********
25 2023-03-03 07:15 27 ********
26 2023-03-03 07:20 28 *********
27 2023-03-03 07:25 27 ********
28 2023-03-03 07:30 27 ********
29 2023-03-03 07:35 28 *********
30 2023-03-03 07:40 27 ********
... ..( 5 skipped). .. ********
36 2023-03-03 08:10 27 ********
37 2023-03-03 08:15 28 *********
38 2023-03-03 08:20 28 *********
39 2023-03-03 08:25 27 ********
40 2023-03-03 08:30 28 *********
41 2023-03-03 08:35 28 *********
42 2023-03-03 08:40 27 ********
43 2023-03-03 08:45 27 ********
44 2023-03-03 08:50 28 *********
... ..( 27 skipped). .. *********
72 2023-03-03 11:10 28 *********
73 2023-03-03 11:15 29 **********
74 2023-03-03 11:20 28 *********
75 2023-03-03 11:25 28 *********
76 2023-03-03 11:30 29 **********
... ..( 7 skipped). .. **********
84 2023-03-03 12:10 29 **********
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0002 4 0 R_ERR response for data FIS
0x0003 4 0 R_ERR response for device-to-host data FIS
0x0004 4 0 R_ERR response for host-to-device data FIS
0x0005 4 0 R_ERR response for non-data FIS
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 5 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 5 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x8e00 4 0 Vendor specific
0x8e01 4 0 Vendor specific
0x8e02 4 0 Vendor specific
0x8e03 4 0 Vendor specific
0x8e04 4 0 Vendor specific
0x8e05 4 0 Vendor specific
0x8e06 4 0 Vendor specific
0x8e07 4 0 Vendor specific
0x8e08 4 0 Vendor specific
0x8e09 4 0 Vendor specific
0x8e0a 4 0 Vendor specific
0x8e0b 4 0 Vendor specific
0x8e0c 4 0 Vendor specific
0x8e0d 4 0 Vendor specific
0x8e0e 4 0 Vendor specific
0x8e0f 4 0 Vendor specific
0x8e10 4 0 Vendor specific
0x8e11 4 0 Vendor specific