| System | |
|---|---|
| Vendor | FUJITSU » |
| Model | D2619 S26361-D2619-N15 WGS10 GS02 » |
| Submodel | PRIMERGY RX300 S6 |
| Year | 2010 |
| HWid | 422FF |
| Type | rack mount |
| BUS | ID / Class | Vendor | Device | Type | Status |
|---|---|---|---|---|---|
| PCI | 102b:0522:1734:108e » / 03-00-00 |
Matrox Electronics Systems Ltd. | MGA G200e [Pilot] ServerEngines (SEP1) | graphics card | tested |
| PCI | 8086:10a7:1734:1128 » / 02-00-00 |
Intel Corporation | 82575EB Gigabit Network Connection | network | tested |
| PCI | 8086:10c9:8086:a02f » / 02-00-00 |
Intel Corporation | 82576 Gigabit Network Connection | network | tested |
| PCI | 8086:10fb:8086:000a » / 02-00-00 |
Intel Corporation | 82599ES 10-Gigabit SFI/SFP+ Network Connection | network | tested |
| PCI | 1000:0079:1734:1176 » / 01-04-00 |
Broadcom / LSI | MegaRAID SAS 2108 [Liberator] | storage | supported |
| PCI | 8086:3a20:1734:1150 » / 01-01-8f |
Intel Corporation | 82801JI (ICH10 Family) 4 port SATA IDE Controller #1 | storage | supported |
| PCI | 8086:3a26:1734:114d » / 01-01-85 |
Intel Corporation | 82801JI (ICH10 Family) 2 port SATA IDE Controller #2 | storage | supported |
| PCI | 8086:244e:1734:114d » / 06-04-01 |
Intel Corporation | 82801 PCI Bridge | bridge | tested |
| PCI | 8086:2c70:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series QuickPath Architecture Generic Non-core Registers | bridge | supported |
| PCI | 8086:2d81:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series QuickPath Architecture System Address Decoder | bridge | supported |
| PCI | 8086:2d90:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series QPI Link 0 | bridge | supported |
| PCI | 8086:2d91:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series QPI Physical 0 | bridge | supported |
| PCI | 8086:2d92:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Mirror Port Link 0 | bridge | supported |
| PCI | 8086:2d93:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Mirror Port Link 1 | bridge | supported |
| PCI | 8086:2d94:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series QPI Link 1 | bridge | supported |
| PCI | 8086:2d95:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series QPI Physical 1 | bridge | supported |
| PCI | 8086:2d98:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Registers | bridge | supported |
| PCI | 8086:2d99:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Target Address Decoder | bridge | supported |
| PCI | 8086:2d9a:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller RAS Registers | bridge | supported |
| PCI | 8086:2d9c:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Test Registers | bridge | supported |
| PCI | 8086:2da0:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Channel 0 Control | bridge | supported |
| PCI | 8086:2da1:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Channel 0 Address | bridge | supported |
| PCI | 8086:2da2:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Channel 0 Rank | bridge | supported |
| PCI | 8086:2da3:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Channel 0 Thermal Control | bridge | supported |
| PCI | 8086:2da8:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Channel 1 Control | bridge | supported |
| PCI | 8086:2da9:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Channel 1 Address | bridge | supported |
| PCI | 8086:2daa:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Channel 1 Rank | bridge | supported |
| PCI | 8086:2dab:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Channel 1 Thermal Control | bridge | supported |
| PCI | 8086:2db0:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Channel 2 Control | bridge | supported |
| PCI | 8086:2db1:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Channel 2 Address | bridge | supported |
| PCI | 8086:2db2:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Channel 2 Rank | bridge | supported |
| PCI | 8086:2db3:1734:1126 » / 06-00-00 |
Intel Corporation | Xeon 5600 Series Integrated Memory Controller Channel 2 Thermal Control | bridge | supported |
| PCI | 8086:3406:1734:1127 » / 06-00-00 |
Intel Corporation | 5520 I/O Hub to ESI Port | bridge | tested |
| PCI | 8086:3408:1734:1127 » / 06-04-00 |
Intel Corporation | 5520/5500/X58 I/O Hub PCI Express Root Port 1 | bridge | tested |
| PCI | 8086:340a:1734:1127 » / 06-04-00 |
Intel Corporation | 5520/5500/X58 I/O Hub PCI Express Root Port 3 | bridge | tested |
| PCI | 8086:340c:1734:1127 » / 06-04-00 |
Intel Corporation | 5520/X58 I/O Hub PCI Express Root Port 5 | bridge | supported |
| PCI | 8086:340e:1734:1127 » / 06-04-00 |
Intel Corporation | 5520/5500/X58 I/O Hub PCI Express Root Port 7 | bridge | tested |
| PCI | 8086:340f:1734:1127 » / 06-04-00 |
Intel Corporation | 5520/5500/X58 I/O Hub PCI Express Root Port 8 | bridge | supported |
| PCI | 8086:3410:1734:1127 » / 06-04-00 |
Intel Corporation | 7500/5520/5500/X58 I/O Hub PCI Express Root Port 9 | bridge | tested |
| PCI | 8086:3411:1734:1127 » / 06-04-00 |
Intel Corporation | 7500/5520/5500/X58 I/O Hub PCI Express Root Port 10 | bridge | supported |
| PCI | 8086:3a18:1734:114d » / 06-01-00 |
Intel Corporation | 82801JIB (ICH10) LPC Interface Controller | bridge | tested |
| PCI | 8086:3a40:1734:114d » / 06-04-00 |
Intel Corporation | 82801JI (ICH10 Family) PCI Express Root Port 1 | bridge | tested |
| PCI | 8086:3a48:1734:114d » / 06-04-00 |
Intel Corporation | 82801JI (ICH10 Family) PCI Express Root Port 5 | bridge | tested |
| PCI | 8086:3a30:1734:114d » / 0c-05-00 |
Intel Corporation | 82801JI (ICH10 Family) SMBus Controller | smbus | tested |
| PCI | 8086:3422:0034:0027 » / 08-00-00 |
Intel Corporation | 7500/5520/5500/X58 I/O Hub GPIO and Scratch Pad Registers | system peripheral | supported |
| PCI | 8086:3423:0034:0027 » / 08-00-00 |
Intel Corporation | 7500/5520/5500/X58 I/O Hub Control Status and RAS Registers | system peripheral | supported |
| PCI | 8086:3425:0034:0027 » / 08-00-00 |
Intel Corporation | 7500/5520/5500/X58 Physical and Link Layer Registers Port 0 | system peripheral | supported |
| PCI | 8086:3426:0034:0027 » / 08-00-00 |
Intel Corporation | 7500/5520/5500/X58 Routing and Protocol Layer Registers Port 0 | system peripheral | supported |
| PCI | 8086:3427:0034:0027 » / 08-00-00 |
Intel Corporation | 7500/5520/5500 Physical and Link Layer Registers Port 1 | system peripheral | supported |
| PCI | 8086:3428:0034:0027 » / 08-00-00 |
Intel Corporation | 7500/5520/5500 Routing & Protocol Layer Register Port 1 | system peripheral | supported |
| PCI | 8086:3429:1734:1127 » / 08-80-00 |
Intel Corporation | 5520/5500/X58 Chipset QuickData Technology Device | system peripheral | tested |
| PCI | 8086:342a:1734:1127 » / 08-80-00 |
Intel Corporation | 5520/5500/X58 Chipset QuickData Technology Device | system peripheral | tested |
| PCI | 8086:342b:1734:1127 » / 08-80-00 |
Intel Corporation | 5520/5500/X58 Chipset QuickData Technology Device | system peripheral | tested |
| PCI | 8086:342c:1734:1127 » / 08-80-00 |
Intel Corporation | 5520/5500/X58 Chipset QuickData Technology Device | system peripheral | tested |
| PCI | 8086:342e:0034:0027 » / 08-00-00 |
Intel Corporation | 7500/5520/5500/X58 I/O Hub System Management Registers | system peripheral | supported |
| PCI | 8086:342f:0034:0027 » / 08-00-20 |
Intel Corporation | 7500/5520/5500/X58 Trusted Execution Technology Registers | system peripheral | supported |
| PCI | 8086:3430:1734:1127 » / 08-80-00 |
Intel Corporation | 5520/5500/X58 Chipset QuickData Technology Device | system peripheral | tested |
| PCI | 8086:3431:1734:1127 » / 08-80-00 |
Intel Corporation | 5520/5500/X58 Chipset QuickData Technology Device | system peripheral | tested |
| PCI | 8086:3432:1734:1127 » / 08-80-00 |
Intel Corporation | 5520/5500/X58 Chipset QuickData Technology Device | system peripheral | tested |
| PCI | 8086:3433:1734:1127 » / 08-80-00 |
Intel Corporation | 5520/5500/X58 Chipset QuickData Technology Device | system peripheral | tested |
| PCI | 8086:3438:0034:0027 » / 08-00-00 |
Intel Corporation | 7500/5520/5500/X58 I/O Hub Throttle Registers | system peripheral | supported |
| PCI | 8086:3a34:1734:114d » / 0c-03-00 |
Intel Corporation | 82801JI (ICH10 Family) USB UHCI Controller #1 | usb controller | tested |
| PCI | 8086:3a35:1734:114d » / 0c-03-00 |
Intel Corporation | 82801JI (ICH10 Family) USB UHCI Controller #2 | usb controller | tested |
| PCI | 8086:3a36:1734:114d » / 0c-03-00 |
Intel Corporation | 82801JI (ICH10 Family) USB UHCI Controller #3 | usb controller | tested |
| PCI | 8086:3a37:1734:114d » / 0c-03-00 |
Intel Corporation | 82801JI (ICH10 Family) USB UHCI Controller #4 | usb controller | tested |
| PCI | 8086:3a38:1734:114d » / 0c-03-00 |
Intel Corporation | 82801JI (ICH10 Family) USB UHCI Controller #5 | usb controller | tested |
| PCI | 8086:3a39:1734:114d » / 0c-03-00 |
Intel Corporation | 82801JI (ICH10 Family) USB UHCI Controller #6 | usb controller | tested |
| PCI | 8086:3a3a:1734:114d » / 0c-03-20 |
Intel Corporation | 82801JI (ICH10 Family) USB2 EHCI Controller #1 | usb controller | tested |
| PCI | 8086:3a3c:1734:114d » / 0c-03-20 |
Intel Corporation | 82801JI (ICH10 Family) USB2 EHCI Controller #2 | usb controller | tested |
| USB | 1d6b:0001 » / 09-00-00 |
BSD | 1.1 root hub | hub | tested |
| USB | 1d6b:0002 » / 09-00-00 |
BSD | 2.0 root hub | hub | tested |
| SYS | fujitsu-phoenix-6-00-rev-1-09-2619-n1-12-13-2010 | FUJITSU // Phoenix Technologies Ltd. | BIOS 6.00 Rev. 1.09.2619.N1 12/13/2010 | bios | supported |
| SYS | intel-6-44-2-xeon | Intel | Xeon CPU E5640 | cpu | supported |
| SYS | ram-module-8gb-ddr3-1066-dimm [537] » | RAM Module 8GB DIMM DDR3 1066MT/s | memory | tested | |
| SYS | ram-module-8gb-ddr3-1066-dimm [537] » | RAM Module 8GB DIMM DDR3 1066MT/s | memory | tested | |
| SYS | fujitsu-d2619-s26361-d2619-n15-wgs10-gs02 » | FUJITSU | Motherboard D2619 S26361-D2619-N15 WGS10 GS02 | motherboard | tested |
| SCSI | optiarc-dvd-rw-ad-7710h » | Optiarc | DVD RW AD-7710H | cdrom | tested
|